2,577 research outputs found

    Genuine lab experiences for students in resource constrained environments: The RealLab with integrated intelligent assessment.

    Get PDF
    Laboratory activities are indispensable for developing engineering skills. Computer Aided Learning (CAL) tools can be used to enhance laboratory learning in various ways, the latest approach being the virtual laboratory technique that emulates traditional laboratory processes. This new approach makes it possible to give students complete and genuine laboratory experiences in situations constrained by limited resources in the provision of laboratory facilities and infrastructure and/or where there is need for laboratory education, for large classes, with only one laboratory stand. This may especially be the case in countries in transition. Most existing virtual laboratories are not available for purchase. Where they are, they may not be cost friendly for resource constrained environments. Also, most do not integrate any form of assessment structure. In this paper, we present a very cost friendly virtual laboratory solution for genuine laboratory experiences in resource constrained environments, with integrated intelligent assessment

    An investigation into linearity with cumulative emissions of the climate and carbon cycle response in HadCM3LC

    Get PDF
    We investigate the extent to which global mean temperature, precipitation, and the carbon cycle are constrained by cumulative carbon emissions throughout four experiments with a fully coupled climate-carbon cycle model. The two paired experiments adopt contrasting, idealised approaches to climate change mitigation at different action points this century, with total emissions exceeding two trillion tonnes of carbon in the later pair. Their initially diverging cumulative emissions trajectories cross after several decades, before diverging again. We find that their global mean temperatures are, to first order, linear with cumulative emissions, though regional differences in temperature of up to 1.5K exist when cumulative emissions of each pair coincide. Interestingly, although the oceanic precipitation response scales with cumulative emissions, the global precipitation response does not, due to a decrease in precipitation over land above cumulative emissions of around one trillion tonnes of carbon (TtC). Most carbon fluxes and stores are less well constrained by cumulative emissions as they reach two trillion tonnes. The opposing mitigation approaches have different consequences for the Amazon rainforest, which affects the linearity with which the carbon cycle responds to cumulative emissions. Averaged over the two fixed-emissions experiments, the transient response to cumulative carbon emissions (TCRE) is 1.95 K TtC-1, at the upper end of the IPCC’s range of 0.8-2.5 K TtC-1

    Holocene carbon-cycle dynamics based on CO2 trapped in ice at Taylor Dome, Antarctica

    Get PDF
    A high-resolution ice-core record of atmospheric CO2 concentration over the Holocene epoch shows that the global carbon cycle has not been in steady state during the past 11,000 years. Analysis of the CO2 concentration and carbon stable-isotope records, using a one-dimensional carbon-cycle model,uggests that changes in terrestrial biomass and sea surface temperature were largely responsible for the observed millennial-scale changes of atmospheric CO2 concentrations

    Arabic version of the Personality Inventory for the DSM-5 (PID-5) in a community sample of United Arab Emirates nationals

    Get PDF
    Background: Section III of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5) proposes a model for conceptualizing personality disorders in which they are characterized by impairments in personality functioning and maladaptive personality traits. The Personality Inventory for DSM-5 (PID-5) is a self-report measure that assesses the presence and severity of these maladaptive personality traits. Objective: The current study examined the reliability and validity of the Arabic version of the Personality Inventory for DSM-5 (PID-5) to measure maladaptive personality traits in the Emirati population of the United Arab Emirates. Methods: The Arabic version of the PID-5 was administered to a community sample of 1,090 United Arab Emirates nationals (89.5% female and 10.5% male, mean age = 22.44 years old). The descriptive measures, internal consistency, test-retest reliability, convergent validity with NEO – Five Factor Inventory, as well as PID-5’s factor structure, were all addressed. Results: The PID-5facets and domains mean scores were higher in the Emirati sample compared to the original US sample. Internal consistency of the PID-5 scales was acceptable to high and test-retest coefficients ranged from 0.84 (facets) to 0.87 (domains). As expected, the five domains of the Arabic version of the PID-5 correlated significantly with all Five-Factor Model domains of personality. Additionally, the Arabic version of the PID-5 confirmed a five-factor structure that resembles the PID-5 domains. Conclusion: The findings of this study provided initial support for the use of the Arabic version of the PID-5 to assess maladaptive personality traits in the Emirati population of the United Arab Emirates.info:eu-repo/semantics/publishedVersio

    Radiative Extinction of Gaseous Spherical Diffusion Flames in Microgravity

    Get PDF
    Radiative extinction of spherical diffusion flames was investigated experimentally and numerically. The experiments involved microgravity spherical diffusion flames burning ethylene and propane at 0.98 bar. Both normal (fuel flowing into oxidizer) and inverse (oxidizer flowing into fuel) flames were studied, with nitrogen supplied to either the fuel or the oxygen. Flame conditions were chosen to ensure that the flames extinguished within the 2.2 s of available test time; thus extinction occurred during unsteady flame conditions. Diagnostics included color video and thin-filament pyrometry. The computations, which simulated flow from a porous sphere into a quiescent environment, included detailed chemistry, transport and radiation, and yielded transient results. Radiative extinction was observed experimentally and simulated numerically. Extinction time, peak temperature, and radiative loss fraction were found to be independent of flow rate except at very low flow rates. Radiative heat loss was dominated by the combustion products downstream of the flame and was found to scale with flame surface area, not volume. For large transient flames the heat release rate also scaled with surface area and thus the radiative loss fraction was largely independent of flow rate. Peak temperatures at extinction onset were about 1100 K, which is significantly lower than for kinetic extinction. One observation of this work is that while radiative heat losses can drive transient extinction, this is not because radiative losses are increasing with time (flame size) but rather because the heat release rate is falling off as the temperature drops

    Size-Extensive Molecular Machine Learning with Global Representations

    Get PDF
    Machine learning (ML) models are increasingly used in combination with electronic structure calculations to predict molecular properties at a much lower computational cost in high-throughput settings. Such ML models require representations that encode the molecular structure, which are generally designed to respect the symmetries and invariances of the target property. However, size-extensivity is usually not guaranteed for so-called global representations. In this contribution, we show how extensivity can be built into global ML models using, e. g., the Many-Body Tensor Representation. Properties of extensive and non-extensive models for the atomization energy are systematically explored by training on small molecules and testing on small, medium and large molecules. Our results show that non-extensive models are only useful in the size-range of their training set, whereas extensive models provide reasonable predictions across large size differences. Remaining sources of error for extensive models are discussed

    Subocclusive transvenous approach of dural arteriovenous fistula

    Get PDF
    Introdução: As fístulas arteriovenosas durais (FAVd) são usualmente adquiridas e quando apresentam drenagem venosa cortical estão associadas a um risco elevado de hemorragia. Podem ser tratadas por embolização (transarterial ou transvenosa), cirurgicamente ou pela combinação das duas técnicas. A embolização por via transvenosa induz uma trombose iatrogénica do seio venoso, acarretando risco de enfarte venoso e/ou hemorragia. Objectivo: Rever os casos de FAVd do seio lateral submetidas a embolização transvenosa. O nosso principal objectivo é avaliar a eficácia e a morbilidade deste tipo de tratamento e o segundo é discutir as possíveis vantagens de uma abordagem suboclusiva na primeira sessão de tratamento. Resultados: Os autores apresentam seis casos clínicos de FAVd, cujas formas de apresentação foram: diminuição da acuidade visual (3); sopro pulsátil no ouvido (3); cefaleias (2); hemorragia subaracnoideia (1); hipoacusia subjectiva (1); edema da papila (1); défice motor (1). Angiograficamente: Cognard IIa (3), IIab (2) e IV (1), todas com envolvimento dos seios laterais. As principais aferências eram: ACE ipsilateral (6); ACI ipsilateral (6); AV ipsilateral (6); ACE contralateral (5); AV contralateral (5); ACI contralateral (3); ACP ipsilateral (1). O tratamento inicial foi sempre a abordagem transarterial, com resultados angiográficos aceitáveis, embora transitórios. Posteriormente optou-se pela via transvenosa com preenchimento do seio lateral com GDC coils. Em cinco dos doentes decidiu-se pela suboclusão, com persistência de algumas aferências. Em quatro, a angiografia subsequente demonstrou trombose “espontânea” do seio lateral com resolução clínica e angiográfica da doença. Num deles a trombose ocorreu ainda durante a sessão inicial. Todos os procedimentos decorreram sem complicações e nenhum dos doentes desenvolveu novos défices neurológicos focais. Conclusões: A abordagem transvenosa das FAVd obteve um sucesso técnico e clínico assinalável, sem presença de complicações. Pensamos que a suboclusão do seio venoso com coils poderá induzir menor alteração hemodinâmica aguda, possibilitando uma trombose mais lenta, diminuindo o risco de complicações, mas com resolução angiográfica ulterior da FAVd

    Neutron star properties in a chiral SU(3) model

    Full text link
    We investigate various properties of neutron star matter within an effective chiral SU(3)L×SU(3)RSU(3)_L \times SU(3)_R model. The predictions of this model are compared with a Walecka-type model. It is demonstrated that the importance of hyperon degrees are strongly depending on the interaction used, even if the equation of state near saturation density is nearly the same in both models. While the Walecka-type model predicts a strange star core with strangeness fraction fS4/3f_S \approx 4/3, the chiral model allows only for fS1/3f_S \approx 1/3 and predicts that Σ0\Sigma^0, Σ+\Sigma^+ and Ξ0\Xi^0 will not exist in star, in contrast to the Walecka-type model.Comment: 13 pages, Revtex, 5 figs include
    corecore