18 research outputs found
Sensitivity and Specificity of Multiple Kato-Katz Thick Smears and a Circulating Cathodic Antigen Test for Schistosoma mansoni Diagnosis Pre- and Post-repeated-Praziquantel Treatment
Two Kato-Katz thick smears (Kato-Katzs) from a single stool are currently recommended for diagnosing Schistosoma mansoni infections to map areas for intervention. This ‘gold standard’ has low sensitivity at low infection intensities. The urine point-of-care circulating cathodic antigen test (POC-CCA) is potentially more sensitive but how accurately they detect S. mansoni after repeated praziquantel treatments, their suitability for measuring drug efficacy and their correlation with egg counts remain to be fully understood. We compared the accuracies of one to six Kato-Katzs and one POC-CCA for the diagnosis of S. mansoni in primary-school children who have received zero to ten praziquantel treatments. We determined the impact each diagnostic approach may have on monitoring and evaluation (M&E) and drug-efficacy findings
Effects of Music Therapy on Mood in Stroke Patients
PURPOSE: To investigate the effects of music therapy on depressive mood and anxiety in post-stroke patients and evaluate satisfaction levels of patients and caregivers.
MATERIALS AND METHODS: Eighteen post-stroke patients, within six months of onset and mini mental status examination score of over 20, participated in this study. Patients were divided into music and control groups. The experimental group participated in the music therapy program for four weeks. Psychological status was evaluated with the Beck Anxiety Inventory (BAI) and Beck Depression Inventory (BDI) before and after music therapy. Satisfaction with music therapy was evaluated by a questionnaire.
RESULTS: BAI and BDI scores showed a greater decrease in the music group than the control group after music therapy, but only the decrease of BDI scores were statistically significant (p=0.048). Music therapy satisfaction in patients and caregivers was affirmative.
CONCLUSION: Music therapy has a positive effect on mood in post-stroke patients and may be beneficial for mood improvement with stroke. These results are encouraging, but further studies are needed in this field.ope
Evaluation of Urine CCA Assays for Detection of Schistosoma mansoni Infection in Western Kenya
Although accurate assessment of the prevalence of Schistosoma mansoni is important for the design and evaluation of control programs, the most widely used tools for diagnosis are limited by suboptimal sensitivity, slow turn-around-time, or inability to distinguish current from former infections. Recently, two tests that detect circulating cathodic antigen (CCA) in urine of patients with schistosomiasis became commercially available. As part of a larger study on schistosomiasis prevalence in young children, we evaluated the performance and diagnostic accuracy of these tests—the carbon test strip designed for use in the laboratory and the cassette format test intended for field use. In comparison to 6 Kato-Katz exams, the carbon and cassette CCA tests had sensitivities of 88.4% and 94.2% and specificities of 70.9% and 59.4%, respectively. However, because of the known limitations of the Kato-Katz assay, we also utilized latent class analysis (LCA) incorporating the CCA, Kato-Katz, and schistosome-specific antibody results to determine their sensitivities and specificities. The laboratory-based CCA test had a sensitivity of 91.7% and a specificity of 89.4% by LCA while the cassette test had a sensitivity of 96.3% and a specificity of 74.7%. The intensity of the reaction in both urine CCA tests reflected stool egg burden and their performance was not affected by the presence of soil transmitted helminth infections. Our results suggest that urine-based assays for CCA may be valuable in screening for S. mansoni infections
Recommended from our members
SEIS: Insight's Seismic Experiment for Internal Structure of Mars.
By the end of 2018, 42 years after the landing of the two Viking seismometers on Mars, InSight will deploy onto Mars' surface the SEIS (Seismic Experiment for Internal Structure) instrument; a six-axes seismometer equipped with both a long-period three-axes Very Broad Band (VBB) instrument and a three-axes short-period (SP) instrument. These six sensors will cover a broad range of the seismic bandwidth, from 0.01 Hz to 50 Hz, with possible extension to longer periods. Data will be transmitted in the form of three continuous VBB components at 2 sample per second (sps), an estimation of the short period energy content from the SP at 1 sps and a continuous compound VBB/SP vertical axis at 10 sps. The continuous streams will be augmented by requested event data with sample rates from 20 to 100 sps. SEIS will improve upon the existing resolution of Viking's Mars seismic monitoring by a factor of ∼ 2500 at 1 Hz and ∼ 200 000 at 0.1 Hz. An additional major improvement is that, contrary to Viking, the seismometers will be deployed via a robotic arm directly onto Mars' surface and will be protected against temperature and wind by highly efficient thermal and wind shielding. Based on existing knowledge of Mars, it is reasonable to infer a moment magnitude detection threshold of M w ∼ 3 at 40 ∘ epicentral distance and a potential to detect several tens of quakes and about five impacts per year. In this paper, we first describe the science goals of the experiment and the rationale used to define its requirements. We then provide a detailed description of the hardware, from the sensors to the deployment system and associated performance, including transfer functions of the seismic sensors and temperature sensors. We conclude by describing the experiment ground segment, including data processing services, outreach and education networks and provide a description of the format to be used for future data distribution.Electronic supplementary materialThe online version of this article (10.1007/s11214-018-0574-6) contains supplementary material, which is available to authorized users
Adolescents' experience of comments about their weight – prevalence, accuracy and effects on weight misperception
<p>Abstract</p> <p>Background</p> <p>Weight comments are commonly received by adolescents, but the accuracy of the comments and their effects on weight misperception are unclear. We assessed the prevalence and accuracy of weight comments received by Chinese adolescents from different sources and their relation to weight misperception.</p> <p>Methods</p> <p>In the Hong Kong Student Obesity Surveillance (HKSOS) project 2006–07, 22612 students aged 11–18 (41.5% boys) completed a questionnaire on obesity. Students responded if family members, peers and professionals had seriously commented over the past 30 days that they were "too fat" or "too thin" in two separate questions. The accuracy of the comments was judged against the actual weight status derived from self-reported height and weight. Self-perceived weight status was also reported and any discordance with the actual weight status denoted weight misperception. Logistic regression yielded adjusted odd ratios for weight misperception by the type of weight comments received.</p> <p>Results</p> <p>One in three students received weight comments, and the mother was the most common source of weight comments. Health professional was the most accurate source of weight comments, yet less than half the comments were correct. Adolescents receiving incorrect comments had increased risk of having weight misperception in all weight status groups. Receiving conflicting comments was positively associated with weight misperception among normal weight adolescents. In contrast, underweight and overweight/obese adolescents receiving correct weight comments were less likely to have weight misperception.</p> <p>Conclusion</p> <p>Weight comments, mostly incorrect, were commonly received by Chinese adolescents in Hong Kong, and such incorrect comments were associated with weight misperception.</p