25 research outputs found

    Reducing periprosthetic joint infection: What really counts?

    Get PDF
    Periprosthetic joint infection (PJi) remains one of the most challenging complications after joint arthroplasty. Despite improvements in surgical techniques and in the use of antibiotic prophylaxis, it remains a major cause of implant failure and need for revision. PJi is associated with both human host-related and bacterial agentrelated factors that can interact in all the phases of the procedure (preoperative, intraoperative and postoperative). Prevention is the first strategy to implement in order to minimize this catastrophic complication. The present review focuses on the preoperative period, and on what to do once risk factors are fully understood and have been identified

    Multilobulated popliteal cyst after a failed total knee arthroplasty

    Get PDF
    Popliteal cyst is a rare finding after total knee arthroplasty (TKA), but when present, it might indicate a malfunction of the TKA related to generation of wear-particles, or loosening. We present a case of a multilobulated popliteal cyst developing in a patient 8years after primary TKA. The cyst was associated with a mechanical prosthetic loosening. The primary complaint of the patient was pain in the posterior region of the knee. A two-stage procedure consisting of cyst excision at first, followed after 5months by a revision TKA was performed. Intraoperatively, a darkish, multilobulated cyst with a well-defined thick wall filled with fluid containing polyethylene debris, communicating with the knee joint was found. After 3years of follow-up, the patient was satisfied and walked without the support of a cane. The patient presented a satisfactory knee range of motion. Clinical, radiological and ultrasound investigations ruled out popliteal cyst recurrence. A dissecting popliteal cyst associated with a failed TKA should be excised because it contains polyethylene debris that constitutes an induced factor for prosthetic loosening. A two-stage procedure with quite a long time in-between, as presented in this paper, can be a useful alternative to manage such a problem, in particular in very old patients associated with other medical problem

    Prevention of Periprosthetic Joint Infection in Total Hip and Knee Replacement:One European Consensus

    Get PDF
    Periprosthetic joint infection (PJI) is a devastating complication in total hip and knee replacement. Its prevention is key to decrease the incidence and avoid some consequences that seriously impact patients and health systems. In view of the variety of recommendations and guidelines, we decided to conduct an expert, peer-reviewed European consensus analysis about the pre-, intra-, and postoperative prevention of PJI. A multinational group of practicing orthopedic experts developed a series of 47 consensus statements in 6 main groups of intervention, and a 2-stage Delphi approach was launched with a threshold for agreement at 75% and for very high agreement at more than 90%. A total of 306 orthopedic surgeon responses were gathered from 9 countries. Consensus was reached for 42/47 statements, 31/47 of which achieved a very high consensus. Many preoperative actions gathered strong consensus, although areas like the use of alcoholic chlorhexidine or the timing of hair removal did not attain strong consensus, despite available evidence. Intra- and postoperative actions showed more variability regarding incise drapes, skin suturing techniques, and wound follow-up. This study confirms an important consensus among orthopedic surgeons across Europe in many areas well known to contribute to the prevention of PJI; however, there are still grounds for improvement

    The incidence of hip, forearm, humeral, ankle, and vertebral fragility fractures in Italy: results from a 3-year multicenter study

    Get PDF
    INTRODUCTION: We aimed to assess the incidence and hospitalization rate of hip and "minor" fragility fractures in the Italian population. METHODS: We carried out a 3-year survey at 10 major Italian emergency departments to evaluate the hospitalization rate of hip, forearm, humeral, ankle, and vertebral fragility fractures in people 45 years or older between 2004 and 2006, both men and women. These data were compared with those recorded in the national hospitalizations database (SDO) to assess the overall incidence of fragility fractures occurring at hip and other sites, including also those events not resulting in hospital admissions. RESULTS: We observed 29,017 fractures across 3 years, with hospitalization rates of 93.0% for hip fractures, 36.3% for humeral fractures, 31.3% for ankle fractures, 22.6% for forearm/wrist fractures, and 27.6% for clinical vertebral fractures. According to the analyses performed with the Italian hospitalization database in year 2006, we estimated an annual incidence of 87,000 hip, 48,000 humeral, 36,000 ankle, 85,000 wrist, and 155,000 vertebral fragility fractures in people aged 45 years or older (thus resulting in almost 410,000 new fractures per year). Clinical vertebral fractures were recorded in 47,000 events per year. CONCLUSIONS: The burden of fragility fractures in the Italian population is very high and calls for effective preventive strategies

    Outcomes of Ceramic Composite in Total Hip Replacement Bearings: A Single-Center Series

    Get PDF
    Despite the fact that total hip replacement is one of the most successful surgical procedures for treatment of a variety of end-stage hip diseases, the process of osteolysis and implant loosening remains a significant problem, especially in young and high-demand patients. More than 40 years ago, ceramic bearings were introduced due to their mechanical advantage in order to obtain a reduction in wear debris, and due to the conviction that it was possible to minimize friction and wear owing to their mechanical hardness, high chemical stability, surface lubrication by fluids and low friction coefficient. Together with excellent mechanical properties, ceramics have a biological inertness: eventual ceramic debris will lead to a reactive response with a high predominance of fibrocystic cells, rather than macrophagic cells, and absence of giant cells, which is ideal from a biological perspective. As a consequence, they will not trigger the granulomatous reaction necessary to induce periprosthetic osteolysis, and this clearly appears to be of great clinical relevance. In recent years, tribology in manufacturing ceramic components has progressed with significant improvements, owing to the development of the latest generation of ceramic composites that allow for an increased material density and reduced grain size. Currently, ceramic-on-ceramic bearings are considered the attractive counterparts of ceramic- or metal-on-polyethylene ones for patients with a long life expectancy. The aim of this paper is to report the results of total hip replacements performed with a ceramic-on-ceramic articulation made from a ceramic composite in a single center, focusing on its usefulness in specific preoperative diagnosis

    Outcomes of Ceramic Composite in Total Hip Replacement Bearings: A Single-Center Series

    No full text
    Despite the fact that total hip replacement is one of the most successful surgical procedures for treatment of a variety of end-stage hip diseases, the process of osteolysis and implant loosening remains a significant problem, especially in young and high-demand patients. More than 40 years ago, ceramic bearings were introduced due to their mechanical advantage in order to obtain a reduction in wear debris, and due to the conviction that it was possible to minimize friction and wear owing to their mechanical hardness, high chemical stability, surface lubrication by fluids and low friction coefficient. Together with excellent mechanical properties, ceramics have a biological inertness: eventual ceramic debris will lead to a reactive response with a high predominance of fibrocystic cells, rather than macrophagic cells, and absence of giant cells, which is ideal from a biological perspective. As a consequence, they will not trigger the granulomatous reaction necessary to induce periprosthetic osteolysis, and this clearly appears to be of great clinical relevance. In recent years, tribology in manufacturing ceramic components has progressed with significant improvements, owing to the development of the latest generation of ceramic composites that allow for an increased material density and reduced grain size. Currently, ceramic-on-ceramic bearings are considered the attractive counterparts of ceramic- or metal-on-polyethylene ones for patients with a long life expectancy. The aim of this paper is to report the results of total hip replacements performed with a ceramic-on-ceramic articulation made from a ceramic composite in a single center, focusing on its usefulness in specific preoperative diagnosis
    corecore