11 research outputs found

    Prospective Evaluation of Pregnancy-Associated Plasma Protein-A and Outcomes in Patients With Acute Coronary Syndromes

    Get PDF
    ObjectivesThis study sought to investigate whether pregnancy-associated plasma protein-A (PAPP-A) is useful for risk assessment in non–ST-segment elevation acute coronary syndrome (NSTE-ACS).BackgroundPAPP-A is a high molecular weight, zinc-binding metalloproteinase that is associated with vulnerable plaque and may be a predictor of cardiovascular disease and mortality.MethodsWe measured PAPP-A at baseline in 3,782 patients with non NSTE-ACS randomized to ranolazine or placebo in the MERLIN–TIMI 36 (Metabolic Efficiency With Ranolazine for Less Ischemia in Non-ST Elevation Acute Coronary Syndromes) trial and followed for an average of 1 year. A cut point of 6.0 ÎŒIU/ml was chosen from pilot work in this cohort.ResultsPAPP-A >6.0 ÎŒIU/ml at presentation was associated with higher rates of cardiovascular death (CVD) or myocardial infarction (MI) at 30 days (7.4% vs. 3.7%, hazard ratio [HR]: 2.01; 95% confidence interval [CI]: 1.43 to 2.82; p < 0.001) and at 1 year (14.9% vs. 9.7%, HR: 1.63; 95% CI: 1.29 to 2.05; p < 0.001). PAPP-A was also associated with higher rates of CVD (HR: 1.94; 95% CI: 1.07 to 3.52, p = 0.027) and myocardial infarction (HR: 1.82; 95% CI: 1.22 to 2.71, p = 0.003) individually at 30 days. There was no difference in the risk associated with PAPP-A stratified by baseline cardiac troponin I [Accu-TnI >0.04 ÎŒg/l], p interaction = 0.87). After adjustment for cardiac troponin I, ST-segment deviation, age, sex, diabetes, smoking, hypertension, and coronary artery disease, PAPP-A was independently associated with CVD/myocardial infarction at 30 days (adjusted HR: 1.62, 95% CI: 1.15 to 2.29; p = 0.006) and 1 year (adjusted HR: 1.35, 95% CI: 1.07 to 1.71; p = 0.012). PAPP-A also improved the net reclassification for CVD/MI (p = 0.003). There was no significant interaction with ranolazine.ConclusionsPAPP-A was independently associated with recurrent cardiovascular events in patients with NSTE-ACS. This finding supports PAPP-A as a candidate prognostic marker in patients with ACS and supports investigation of its therapeutic implications

    Calibration of the CMS hadron calorimeters using proton-proton collision data at root s=13 TeV

    Get PDF
    Methods are presented for calibrating the hadron calorimeter system of theCMSetector at the LHC. The hadron calorimeters of the CMS experiment are sampling calorimeters of brass and scintillator, and are in the form of one central detector and two endcaps. These calorimeters cover pseudorapidities vertical bar eta vertical bar ee data. The energy scale of the outer calorimeters has been determined with test beam data and is confirmed through data with high transverse momentum jets. In this paper, we present the details of the calibration methods and accuracy.Peer reviewe

    Immune monitoring with iTAg MHCTetramers for prediction of recurrent or persistent cytomegalovirus infection or disease in allogeneic hematopoietic stem cell transplant recipients: A prospective multicenter study

    No full text
    Cytomegalovirus (CMV) infection is an important cause of morbidity and mortality in hematopoietic stem cell transplant recipients despite the introduction of posttransplantation viral monitoring and preemptive antiviral therapy. We evaluated the use of HLA class I tetramers in monitoring CMV-specific T-cell recovery to predict patients at risk for CMV-related complications. This prospective multicenter clinical trial obtained nearly 1400 tetramer/allele results in more than 800 biweekly blood samples from 83 patients monitored for 1 year after transplantation. Major HLA types were included (A*0101, A*0201, B*0702, B*0801, B*3501). iTAg MHC Tetramers (Beckman Coulter) were used to enumerate CMV-specific CD8+T cells by flow cytometry using a single-platform absolute counting method. Assay variability was 8% or less and results were available within 3 hours. Delayed recovery of CMV-specific T cells (<7 cells/ÎŒL in all blood samples during the first 65 days after transplantation) was found to be a significant risk factor for CMV-related complications; these patients were more likely to develop recurrent or persistent CMV infection (relative risk 2.6, CI 1.2-5.8, P=.01) than patients showing rapid recovery, which was associated with protection from CMV-related complications (P = .004). CMV tetramer-based immune monitoring, in conjunction with virologic monitoring, can be an important new tool to assess risk of CMV-related complications and to guide preemptive therapeutic choices

    Absolute and Relative Changes (Delta) in Troponin I for Early Diagnosis of Myocardial Infarction: Results of a Prospective Multicenter Trial.

    No full text
    OBJECTIVES: We investigated absolute and relative cardiac troponin I (TnI) delta changes, optimal sampling protocols, and decision thresholds for early diagnosis of myocardial infarction (MI). Serial cardiac biomarker values demonstrating a rise and/or fall define MI diagnosis; however the magnitude of change, timing, and diagnostic accuracy of absolute versus relative (percentage) deltas remains unsettled. METHODS: We prospectively measured TnI (AccuTnI+3ℱ, Beckman Coulter) at serial time intervals in 1929 subjects with chest pain or equivalent symptoms of acute coronary syndrome at 14 medical centers. Diagnosis was adjudicated by an independent central committee. RESULTS: Elevated TnI above a threshold of 0.03ng/mL demonstrated significant diagnostic efficacy (AUC 0.96). For patients with TnI\u3c0.03ng/mL and symptom onset≄8h, 99.1% (NPV) were diagnosed with conditions other than MI. Absolute delta performed significantly better than relative delta at 1-3h (AUC 0.84 vs 0.69), 3-6h (0.85 vs 0.73), and 6-9h (0.91 vs 0.79). Current recommendations propose ≄20% delta within 3-6h; however, results were optimized using an absolute delta of 0.01 or 0.02ng/mL. Sensitivity results for absolute delta at 1-3h and 3-6h (75.8%, 78.3%) were superior to relative delta (48.0%, 61.3%). NPV (rule out) was 99.6% when baseline TnI\u3c0.03ng/mL and absolute delta TnI\u3c0.01ng/mL. CONCLUSIONS: Absolute delta performed significantly better than relative delta at all time intervals. Baseline TnI and absolute delta may be used in conjunction to estimate probability of MI. Consensus recommendations are supported for sampling on admission and 3h later, repeated at 6h in patients when clinical suspicion remains high

    Diagnostic Performance of Cardiac Troponin I for Early Rule-In and Rule-Out of Acute Myocardial Infarction: Results of a Prospective Multicenter Trial

    No full text
    OBJECTIVES: To compare emergency department TnI serial sampling intervals, determine optimal diagnostic thresholds, and report representative diagnostic performance characteristics for early rule-in and rule-out of MI. METHODS: We prospectively measured TnI (AccuTnI+3ℱ, Beckman Coulter) at serial time intervals in 1929 subjects with chest pain or equivalent ischemic symptoms suggestive of acute coronary syndromes at 14 medical centers. Diagnosis was adjudicated by an independent central committee. RESULTS: TnI ≄0.03ng/mL provided 96.0% sensitivity and 89.4% specificity at 1-3h after admission, and 94.9% sensitivity and 86.7% specificity at 3-6h. NPV (rule-out, non-MI) was 99.5% at 1-3h, and 99.0% at 3-6h when TnI is \u3c0.03ng/mL. NPV was 99.1% when TnI is \u3c0.03ng/mL and time of symptom onset is ≄8h. Approximately 50-58% (PPV) of patients with TnI ≄0.03ng/mL were diagnosed with MI, depending upon time from onset or admission; PPVs emphasize the importance of serial samples and delta TnI (rising or falling pattern) when low cutoffs are used. Nevertheless, even a single elevated TnI value increased the risk of MI. As TnI values rose, the probability of MI increased. Values ≄0.20ng/mL were associated with nearly 90% probability of MI. CONCLUSIONS: We report a large multicenter prospective adjudicated trial assessing troponin for early rule-in and rule-out using the Universal Definition of MI and conducted in primary care hospital-associated emergency departments. Our study demonstrates high diagnostic accuracy at early observation times, and reinforces consensus recommendations for sampling on admission and 3h later, repeated at 6h when clinical suspicion remains high

    Measurements of dose-rate effects in the radiation damage of plastic scintillator tiles using silicon photomultipliers

    No full text
    Measurements are presented of the reduction of signal output due to radiation damage for plastic scintillator tiles used in the hadron endcap (HE) calorimeter of the CMS detector. The tiles were exposed to particles produced in proton-proton (pp) collisions at the CERN LHC with a center-of-mass energy of 13 TeV, corresponding to a delivered luminosity of 50 fb−1^{-1}. The measurements are based on readout channels of the HE that were instrumented with silicon photomultipliers, and are derived using data from several sources: a laser calibration system, a movable radioactive source, as well as hadrons and muons produced in pp collisions. Results from several irradiation campaigns using 60^{60}Co sources are also discussed. The damage is presented as a function of dose rate. Within the range of these measurements, for a fixed dose the damage increases with decreasing dose rate

    Measurements of dose-rate effects in the radiation damage of plastic scintillator tiles using silicon photomultipliers

    No full text
    Measurements are presented of the reduction of signal output due to radiation damage for plastic scintillator tiles used in the hadron endcap (HE) calorimeter of the CMS detector. The tiles were exposed to particles produced in proton-proton (pp) collisions at the CERN LHC with a center-of-mass energy of 13 TeV, corresponding to a delivered luminosity of 50 fb−1^{-1}. The measurements are based on readout channels of the HE that were instrumented with silicon photomultipliers, and are derived using data from several sources: a laser calibration system, a movable radioactive source, as well as hadrons and muons produced in pp collisions. Results from several irradiation campaigns using 60^{60}Co sources are also discussed. The damage is presented as a function of dose rate. Within the range of these measurements, for a fixed dose the damage increases with decreasing dose rate
    corecore