25 research outputs found

    Lancet commission on hypertension group position statement on the global improvement of accuracy standards for devices that measure blood pressure

    Get PDF
    The Lancet Commission on Hypertension identified that a key action to address the worldwide burden of high blood pressure (BP) was to improve the quality of BP measurements by using BP devices that have been validated for accuracy. Currently, there are over 3000 commercially available BP devices, but many do not have published data on accuracy testing according to established scientific standards. This problem is enabled through weak or absent regulations that allow clearance of devices for commercial use without formal validation. In addition, new BP technologies have emerged (e.g. cuffless sensors) for which there is no scientific consensus regarding BP measurement accuracy standards. Altogether, these issues contribute to the widespread availability of clinic and home BP devices with limited or uncertain accuracy, leading to inappropriate hypertension diagnosis, management and drug treatment on a global scale. The most significant problems relating to the accuracy of BP devices can be resolved by the regulatory requirement for mandatory independent validation of BP devices according to the universally-accepted International Organisation for Standardization Standard. This is a primary recommendation for which there is an urgent international need. Other key recommendations are development of validation standards specifically for new BP technologies and online lists of accurate devices that are accessible to consumers and health professionals. Recommendations are aligned with WHO policies on medical devices and universal healthcare. Adherence to recommendations would increase the global availability of accurate BP devices and result in better diagnosis and treatment of hypertension, thus decreasing the worldwide burden from high BP

    Why Are Outcomes Different for Registry Patients Enrolled Prospectively and Retrospectively? Insights from the Global Anticoagulant Registry in the FIELD-Atrial Fibrillation (GARFIELD-AF).

    Get PDF
    Background: Retrospective and prospective observational studies are designed to reflect real-world evidence on clinical practice, but can yield conflicting results. The GARFIELD-AF Registry includes both methods of enrolment and allows analysis of differences in patient characteristics and outcomes that may result. Methods and Results: Patients with atrial fibrillation (AF) and ≥1 risk factor for stroke at diagnosis of AF were recruited either retrospectively (n = 5069) or prospectively (n = 5501) from 19 countries and then followed prospectively. The retrospectively enrolled cohort comprised patients with established AF (for a least 6, and up to 24 months before enrolment), who were identified retrospectively (and baseline and partial follow-up data were collected from the emedical records) and then followed prospectively between 0-18 months (such that the total time of follow-up was 24 months; data collection Dec-2009 and Oct-2010). In the prospectively enrolled cohort, patients with newly diagnosed AF (≤6 weeks after diagnosis) were recruited between Mar-2010 and Oct-2011 and were followed for 24 months after enrolment. Differences between the cohorts were observed in clinical characteristics, including type of AF, stroke prevention strategies, and event rates. More patients in the retrospectively identified cohort received vitamin K antagonists (62.1% vs. 53.2%) and fewer received non-vitamin K oral anticoagulants (1.8% vs . 4.2%). All-cause mortality rates per 100 person-years during the prospective follow-up (starting the first study visit up to 1 year) were significantly lower in the retrospective than prospectively identified cohort (3.04 [95% CI 2.51 to 3.67] vs . 4.05 [95% CI 3.53 to 4.63]; p = 0.016). Conclusions: Interpretations of data from registries that aim to evaluate the characteristics and outcomes of patients with AF must take account of differences in registry design and the impact of recall bias and survivorship bias that is incurred with retrospective enrolment. Clinical Trial Registration: - URL: http://www.clinicaltrials.gov . Unique identifier for GARFIELD-AF (NCT01090362)

    Lancet Commission on Hypertension group position statement on the global improvement of accuracy standards for devices that measure blood pressure.

    Get PDF
    The Lancet Commission on Hypertension identified that a key action to address the worldwide burden of high blood pressure (BP) was to improve the quality of BP measurements by using BP devices that have been validated for accuracy. Currently, there are over 3000 commercially available BP devices, but many do not have published data on accuracy testing according to established scientific standards. This problem is enabled through weak or absent regulations that allow clearance of devices for commercial use without formal validation. In addition, new BP technologies have emerged (e.g. cuffless sensors) for which there is no scientific consensus regarding BP measurement accuracy standards. Altogether, these issues contribute to the widespread availability of clinic and home BP devices with limited or uncertain accuracy, leading to inappropriate hypertension diagnosis, management and drug treatment on a global scale. The most significant problems relating to the accuracy of BP devices can be resolved by the regulatory requirement for mandatory independent validation of BP devices according to the universally-accepted International Organisation for Standardization Standard. This is a primary recommendation for which there is an urgent international need. Other key recommendations are development of validation standards specifically for new BP technologies and online lists of accurate devices that are accessible to consumers and health professionals. Recommendations are aligned with WHO policies on medical devices and universal healthcare. Adherence to recommendations would increase the global availability of accurate BP devices and result in better diagnosis and treatment of hypertension, thus decreasing the worldwide burden from high BP

    May Measurement Month 2017: an analysis of blood pressure screening results worldwide

    No full text
    Background: Increased blood pressure is the biggest contributor to the global burden of disease and mortality. Data suggest that less than half of the population with hypertension is aware of it. May Measurement Month was initiated to raise awareness of the importance of blood pressure and as a pragmatic interim solution to the shortfall in screening programmes. Methods: This cross-sectional survey included volunteer adults (≥18 years) who ideally had not had their blood pressures measured in the past year. Each participant had their blood pressure measured three times and received a a questionnaire about demographic, lifestyle, and environmental factors. The primary objective was to raise awareness of blood pressure, measured by number of countries involved, number of people screened, and number of people who have untreated or inadequately treated hypertension (defined as systolic blood pressure ≥140 mm Hg or diastolic blood pressure ≥90 mm Hg, or both, or on the basis of receiving antihypertensive medication). Multiple imputation was used to estimate the mean of the second and third blood pressure readings if these were not recorded. Measures of association were analysed using linear mixed models. Findings: Data were collected from 1 201 570 individuals in 80 countries. After imputation, of the 1 128 635 individuals for whom a mean of the second and third readings was available, 393 924 (34·9%) individuals had hypertension. 153 905 (17·3%) of 888 616 individuals who were not receiving antihypertensive treatment were hypertensive, and 105 456 (46·3%) of the 227 721 individuals receiving treatment did not have controlled blood pressure. Significant differences in adjusted blood pressures and hypertension prevalence were apparent between regions. Adjusted blood pressure was higher in association with antihypertensive medication, diabetes, cerebrovascular disease, smoking, and alcohol consumption. Blood pressure was higher when measured on the right arm than on the left arm, and blood pressure was highest on Saturdays. Interpretation: Inexpensive global screening of blood pressure is achievable using volunteers and convenience sampling. Pending the set-up of systematic surveillance systems worldwide, MMM will be repeated annually to raise awareness of blood pressure. Funding: International Society of Hypertension, Centers for Disease Control and Prevention, Servier Pharmaceutical Co

    Does sex affect anticoagulant use for stroke prevention in nonvalvular atrial fibrillation?: The prospective global anticoagulant registry in the FIELD-Atrial Fibrillation

    No full text
    Background.Among patients with atrial fibrillation (AF), women are at higher risk of stroke than men. Using prospective cohort data from a large global population of patients with nonvalvular AF, we sought to identify any differences in the use of anticoagulants for stroke prevention in women and men. Methods and Results.This was a prospective multicenter observational registry with 858 randomly selected sites in 30 countries. A total of 17 184 patients with newly diagnosed (.6 weeks) nonvalvular AF and .1 additional investigatordefined stroke risk factor(s) were recruited (March 2010 to June 2013). The main outcome measure was the use of anticoagulants (Vitamin K antagonists, factor Xa inhibitors, and direct thrombin inhibitors) for stroke prevention at AF diagnosis. Of 17 184 patients enrolled, 43.8% were women. More women than men were at moderate-to-high risk of stroke (CHADS2 score .2: 65.1% versus 54.7%). Rates of anticoagulant use were not different overall (60.9% of men versus 60.8% of women) and in patients with a CHADS2 score .2 (adjusted odds ratio for women versus men, 1.00; 95% confidence interval, 0.92.1.09). In patients at low risk (CHA2DS2-VASc of 0 in men and 1 in women), 41.8% of men and 41.1% of women received an anticoagulant. In patients at high risk (CHA2DS2-VASc score .2), 35.4% of men and 38.4% of women did not receive an anticoagulant. Conclusions.These contemporary global data show that anticoagulant use for stroke prevention is no different in men and women with nonvalvular AF. Thromboprophylaxis was, however, suboptimal in substantial proportions of men and women, with underuse in those at moderate-to-high risk of stroke and overuse in those at low risk

    Management and 1-year outcomes of patients with newly diagnosed atrial fibrillation and chronic kidney disease: Results from the prospective garfield-af registry

    No full text
    Background-—Using data from the GARFIELD-AF (Global Anticoagulant Registry in the FIELD–Atrial Fibrillation), we evaluated the impact of chronic kidney disease (CKD) stage on clinical outcomes in patients with newly diagnosed atrial fibrillation (AF). Methods and Results-—GARFIELD-AF is a prospective registry of patients from 35 countries, including patients from Asia (China, India, Japan, Singapore, South Korea, and Thailand). Consecutive patients enrolled (2013–2016) were classified with no, mild, or moderate-to-severe CKD, based on the National Kidney Foundation’s Kidney Disease Outcomes Quality Initiative guidelines. Data on CKD status and outcomes were available for 33 024 of 34 854 patients (including 9491 patients from Asia); 10.9% (n=3613) had moderate-to-severe CKD, 16.9% (n=5595) mild CKD, and 72.1% (n=23 816) no CKD. The use of oral anticoagulants was influenced by stroke risk (ie, post hoc assessment of CHA2DS2-VASc score), but not by CKD stage. The quality of anticoagulant control with vitamin K antagonists did not differ with CKD stage. After adjusting for baseline characteristics and antithrombotic use, both mild and moderate-to-severe CKD were independent risk factors for all-cause mortality. Moderate-to-severe CKD was independently associated with a higher risk of stroke/systemic embolism, major bleeding, new-onset acute coronary syndrome, and new or worsening heart failure. The impact of moderate-to-severe CKD on mortality was significantly greater in patients from Asia than the rest of the world (P=0.001). Conclusions-—In GARFIELD-AF, moderate-to-severe CKD was independently associated with stroke/systemic embolism, major bleeding, and mortality. The effect of moderate-to-severe CKD on mortality was even greater in patients from Asia than the rest of the world

    Evolving antithrombotic treatment patterns for patients with newly diagnosed atrial fibrillation

    No full text
    Objective We studied evolving antithrombotic therapy patterns in patients with newly diagnosed non-valvular atrial fibrillation (AF) and >= 1 additional stroke risk factor between 2010 and 2015

    Two-year outcomes of patients with newly diagnosed atrial fibrillation: results from GARFIELD-AF

    No full text
    The relationship between outcomes and time after diagnosis for patients with non-valvular atrial fibrillation (NVAF) is poorly defined, especially beyond the first year

    International trends in clinical characteristics and oral anticoagulation treatment for patients with atrial fibrillation: Results from the GARFIELD-AF, ORBIT-AF I, and ORBIT-AF II registries

    No full text
    Background Atrial fibrillation (AF) is the most common cardiac arrhythmia in the world. We aimed to provide comprehensive data on international patterns of AF stroke prevention treatment
    corecore