152 research outputs found

    One-particle inclusive CP asymmetries

    Full text link
    One-particle inclusive CP asymmetries in the decays of the type B -> D(*) X are considered in the framework of a QCD based method to calculate the rates for one-particle inclusive decays.Comment: Latex, 13 pages, 6 figures (eps). Analytical and numerical results unchanged, extended discussion of model assumptions and systematic uncertainties. Version to be published in Phys. Rev. D 62, 0960xx. Additional transparencies are available via the WWW at http://www-ttp.physik.uni-karlsruhe.de/Slides

    Optical testbed for the LISA phasemeter

    Get PDF
    The planned spaceborne gravitational wave detector LISA will allow the detection of gravitational waves at frequencies between 0.1 mHz and 1 Hz. A breadboard model for the metrology system aka the phasemeter was developed in the scope of an ESA technology development project by a collaboration between the Albert Einstein Institute, the Technical University of Denmark and the Danish industry partner Axcon Aps. It in particular provides the electronic readout of the main interferometer phases besides auxiliary functions. These include clock noise transfer, ADC pilot tone correction, inter-satellite ranging and data transfer. Besides in LISA, the phasemeter can also be applied in future satellite geodesy missions. Here we show the planning and advances in the implementation of an optical testbed for the full metrology chain. It is based on an ultra-stable hexagonal optical bench. This bench allows the generation of three unequal heterodyne beatnotes with a zero phase combination, thus providing the possibility to probe the phase readout for non-linearities in an optical three signal test. Additionally, the utilization of three independent phasemeters will allow the testing of the auxiliary functions. Once working, components can individually be replaced with flight-qualified hardware in this setup.DLR/50 OQ 1301Bundesministerium f¨ur Wirtschaft und Technologi

    Picometer-Stable Hexagonal Optical Bench to Verify LISA Phase Extraction Linearity and Precision

    Get PDF
    The Laser Interferometer Space Antenna (LISA) and its metrology chain have to fulfill stringent performance requirements to enable the space-based detection of gravitational waves. This implies the necessity of performance verification methods. In particular, the extraction of the interferometric phase, implemented by a phasemeter, needs to be probed for linearity and phase noise contributions. This Letter reports on a hexagonal quasimonolithic optical bench implementing a three-signal test for this purpose. Its characterization as sufficiently stable down to picometer levels is presented as well as its usage for a benchmark phasemeter performance measurement under LISA conditions. These results make it a candidate for the core of a LISA metrology verification facility

    Readout for intersatellite laser interferometry: Measuring low frequency phase fluctuations of HF signals with microradian precision

    Full text link
    Precision phase readout of optical beat note signals is one of the core techniques required for intersatellite laser interferometry. Future space based gravitational wave detectors like eLISA require such a readout over a wide range of MHz frequencies, due to orbit induced Doppler shifts, with a precision in the order of μrad/Hz\mu \textrm{rad}/\sqrt{\textrm{Hz}} at frequencies between 0.1mHz0.1\,\textrm{mHz} and 1Hz1\,\textrm{Hz}. In this paper, we present phase readout systems, so-called phasemeters, that are able to achieve such precisions and we discuss various means that have been employed to reduce noise in the analogue circuit domain and during digitisation. We also discuss the influence of some non-linear noise sources in the analogue domain of such phasemeters. And finally, we present the performance that was achieved during testing of the elegant breadboard model of the LISA phasemeter, that was developed in the scope of an ESA technology development activity.Comment: submitted to Review of Scientific Instruments on April 30th 201

    Single-element dual-interferometer for precision inertial sensing

    Get PDF
    Tracking moving masses in several degrees of freedom with high precision and large dynamic range is a central aspect in many current and future gravitational physics experiments. Laser interferometers have been established as one of the tools of choice for such measurement schemes. Using sinusoidal phase modulation homodyne interferometry allows a drastic reduction of the complexity of the optical setup, a key limitation of multi-channel interferometry. By shifting the complexity of the setup to the signal processing stage, these methods enable devices with a size and weight not feasible using conventional techniques. In this paper we present the design of a novel sensor topology based on deep frequency modulation interferometry: the self-referenced single-element dual-interferometer (SEDI) inertial sensor, which takes simplification one step further by accommodating two interferometers in one optic. Using a combination of computer models and analytical methods we show that an inertial sensor with sub-picometer precision for frequencies above 10 mHz, in a package of a few cubic inches, seems feasible with our approach. Moreover we show that by combining two of these devices it is possible to reach sub-picometer precision down to 2 mHz. In combination with the given compactness, this makes the SEDI sensor a promising approach for applications in high precision inertial sensing for both next-generation space-based gravity missions employing drag-free control, and ground-based experiments employing inertial isolation systems with optical readout. © 2020 by the authors. Licensee MDPI, Basel, Switzerland

    Screening of Heterogeneous Photocatalysts for Water Splitting

    Get PDF
    In this contribution, a simple method for the screening of photocatalytic activity of catalyst materials is presented. The method is based on two steps the immobilization of the photocatalyst and the subsequent testing of their photocatalytic activity, using the gas evolution at the solid liquid interface. Up to four catalysts can be tested under the same conditions. The observed gas evolution for selected photocatalysts is consistent with trends reported in the literature from conventional photocatalytic reactor

    Protonated Imine Linked Covalent Organic Frameworks for Photocatalytic Hydrogen Evolution

    Get PDF
    Covalent organic frameworks COFs have emerged as an important class of organic semiconductors and photocatalysts for the hydrogen evolution reaction HER from water. To optimize their photocatalytic activity, typically the organic moieties constituting the frameworks are considered and the most suitable combinations of them are searched for. However, the effect of the covalent linkage between these moieties on the photocatalytic performance has rarely been studied. Herein, we demonstrate that donor acceptor D A type imine linked COFs can produce hydrogen with a rate as high as 20.7 mmol g 1 h 1 under visible light irradiation, upon protonation of their imine linkages. A significant red shift in light absorbance, largely improved charge separation efficiency, and an increase in hydrophilicity triggered by protonation of the Schiff base moieties in the imine linked COFs, are responsible for the improved photocatalytic performanc

    The Smell of Age: Perception and Discrimination of Body Odors of Different Ages

    Get PDF
    Our natural body odor goes through several stages of age-dependent changes in chemical composition as we grow older. Similar changes have been reported for several animal species and are thought to facilitate age discrimination of an individual based on body odors, alone. We sought to determine whether humans are able to discriminate between body odor of humans of different ages. Body odors were sampled from three distinct age groups: Young (20–30 years old), Middle-age (45–55), and Old-age (75–95) individuals. Perceptual ratings and age discrimination performance were assessed in 41 young participants. There were significant differences in ratings of both intensity and pleasantness, where body odors from the Old-age group were rated as less intense and less unpleasant than body odors originating from Young and Middle-age donors. Participants were able to discriminate between age categories, with body odor from Old-age donors mediating the effect also after removing variance explained by intensity differences. Similarly, participants were able to correctly assign age labels to body odors originating from Old-age donors but not to body odors originating from other age groups. This experiment suggests that, akin to other animals, humans are able to discriminate age based on body odor alone and that this effect is mediated mainly by body odors emitted by individuals of old age

    Effects of Intermittent IL-2 Alone or with Peri-Cycle Antiretroviral Therapy in Early HIV Infection: The STALWART Study

    Get PDF
    The Study of Aldesleukin with and without antiretroviral therapy (STALWART) evaluated whether intermittent interleukin-2 (IL-2) alone or with antiretroviral therapy (ART) around IL-2 cycles increased CD4+ counts compared to no therapy

    ARIA-EAACI statement on asthma and COVID-19 (June 2, 2020)

    Get PDF
    Non peer reviewe
    corecore