386 research outputs found

    Improved Holographic QCD

    Full text link
    We provide a review to holographic models based on Einstein-dilaton gravity with a potential in 5 dimensions. Such theories, for a judicious choice of potential are very close to the physics of large-N YM theory both at zero and finite temperature. The zero temperature glueball spectra as well as their finite temperature thermodynamic functions compare well with lattice data. The model can be used to calculate transport coefficients, like bulk viscosity, the drag force and jet quenching parameters, relevant for the physics of the Quark-Gluon Plasma.Comment: LatEX, 65 pages, 28 figures, 9 Tables. Based on lectures given at several Schools. To appear in the proceedinds of the 5th Aegean School (Milos, Greece

    Search for rare quark-annihilation decays, B --> Ds(*) Phi

    Full text link
    We report on searches for B- --> Ds- Phi and B- --> Ds*- Phi. In the context of the Standard Model, these decays are expected to be highly suppressed since they proceed through annihilation of the b and u-bar quarks in the B- meson. Our results are based on 234 million Upsilon(4S) --> B Bbar decays collected with the BABAR detector at SLAC. We find no evidence for these decays, and we set Bayesian 90% confidence level upper limits on the branching fractions BF(B- --> Ds- Phi) Ds*- Phi)<1.2x10^(-5). These results are consistent with Standard Model expectations.Comment: 8 pages, 3 postscript figues, submitted to Phys. Rev. D (Rapid Communications

    Observation of B0→χc0K*0 and evidence for B+→χc0K*+

    Get PDF
    We present the observation of the decay B 0 → χ c 0 K * 0 as well as evidence of B + → χ c 0 K * + , with an 8.9 and a 3.6 standard deviation significance, respectively, using a data sample of 454 × 10 6 Υ ( 4 S ) → B ¯¯¯ B decays collected with the BABAR detector at the PEP-II B meson factory located at the Stanford Linear Accelerator Center (SLAC). The measured branching fractions are B ( B 0 → χ c 0 K * 0 ) = ( 1.7 ± 0.3 ± 0.2 ) × 10 − 4 and B ( B + → χ c 0 K * + ) = ( 1.4 ± 0.5 ± 0.2 ) × 10 − 4 , where the first quoted errors are statistical and the second are systematic. We obtain a branching fraction upper limit of B ( B + → χ c 0 K * + ) < 2.1 × 10 − 4 at the 90% confidence level

    Intravenous alteplase for stroke with unknown time of onset guided by advanced imaging: systematic review and meta-analysis of individual patient data

    Get PDF
    Background: Patients who have had a stroke with unknown time of onset have been previously excluded from thrombolysis. We aimed to establish whether intravenous alteplase is safe and effective in such patients when salvageable tissue has been identified with imaging biomarkers. Methods: We did a systematic review and meta-analysis of individual patient data for trials published before Sept 21, 2020. Randomised trials of intravenous alteplase versus standard of care or placebo in adults with stroke with unknown time of onset with perfusion-diffusion MRI, perfusion CT, or MRI with diffusion weighted imaging-fluid attenuated inversion recovery (DWI-FLAIR) mismatch were eligible. The primary outcome was favourable functional outcome (score of 0–1 on the modified Rankin Scale [mRS]) at 90 days indicating no disability using an unconditional mixed-effect logistic-regression model fitted to estimate the treatment effect. Secondary outcomes were mRS shift towards a better functional outcome and independent outcome (mRS 0–2) at 90 days. Safety outcomes included death, severe disability or death (mRS score 4–6), and symptomatic intracranial haemorrhage. This study is registered with PROSPERO, CRD42020166903. Findings: Of 249 identified abstracts, four trials met our eligibility criteria for inclusion: WAKE-UP, EXTEND, THAWS, and ECASS-4. The four trials provided individual patient data for 843 individuals, of whom 429 (51%) were assigned to alteplase and 414 (49%) to placebo or standard care. A favourable outcome occurred in 199 (47%) of 420 patients with alteplase and in 160 (39%) of 409 patients among controls (adjusted odds ratio [OR] 1·49 [95% CI 1·10–2·03]; p=0·011), with low heterogeneity across studies (I2=27%). Alteplase was associated with a significant shift towards better functional outcome (adjusted common OR 1·38 [95% CI 1·05–1·80]; p=0·019), and a higher odds of independent outcome (adjusted OR 1·50 [1·06–2·12]; p=0·022). In the alteplase group, 90 (21%) patients were severely disabled or died (mRS score 4–6), compared with 102 (25%) patients in the control group (adjusted OR 0·76 [0·52–1·11]; p=0·15). 27 (6%) patients died in the alteplase group and 14 (3%) patients died among controls (adjusted OR 2·06 [1·03–4·09]; p=0·040). The prevalence of symptomatic intracranial haemorrhage was higher in the alteplase group than among controls (11 [3%] vs two [&lt;1%], adjusted OR 5·58 [1·22–25·50]; p=0·024). Interpretation: In patients who have had a stroke with unknown time of onset with a DWI-FLAIR or perfusion mismatch, intravenous alteplase resulted in better functional outcome at 90 days than placebo or standard care. A net benefit was observed for all functional outcomes despite an increased risk of symptomatic intracranial haemorrhage. Although there were more deaths with alteplase than placebo, there were fewer cases of severe disability or death. Funding: None

    A Precision Measurement of the Lambda_c Baryon Mass

    Full text link
    The Λc+\Lambda_c^+ baryon mass is measured using Λc+ΛKS0K+\Lambda_c^+\to\Lambda K^0_S K^+ and Λc+Σ0KS0K+\Lambda_c^+\to\Sigma^0 K^0_S K^+ decays reconstructed in 232 fb1^{-1} of data collected with the BaBar detector at the PEP-II asymmetric-energy e+ee^+e^- storage ring. The Λc+\Lambda_c^+ mass is measured to be 2286.46±0.14MeV/c22286.46\pm0.14\mathrm{MeV}/c^2. The dominant systematic uncertainties arise from the amount of material in the tracking volume and from the magnetic field strength.Comment: 14 pages, 8 postscript figures, submitted to Phys. Rev.

    Observation of a Charmed Baryon Decaying to D0p at a Mass Near 2.94 GeV/c2

    Get PDF
    A search for charmed baryons decaying to D 0 p reveals two states: the Λ c ( 2880 ) + baryon and a previously unobserved state at a mass of [ 2939.8 ± 1.3 ( stat ) ± 1.0 ( syst ) ]     MeV / c 2 and with an intrinsic width of [ 17.5 ± 5.2 ( stat ) ± 5.9 ( syst ) ]     MeV . Consistent and significant signals are observed for the K − π + and K − π + π − π + decay modes of the D 0 in 287     fb − 1 annihilation data recorded by the BABAR detector at a center-of-mass energy of 10.58 GeV. There is no evidence in the D + p spectrum of doubly charged partners. The mass and intrinsic width of the Λ c ( 2880 ) + baryon and relative yield of the two baryons are also measured

    Search for the rare decay B-0 ->tau(+)tau(-) at BABAR

    Get PDF
    We present the results of a search for the decay B-0 ->tau(+)tau(-) in a data sample of (232 +/- 3)x10(6) Upsilon(4S)-> BB decays using the BABAR detector. Certain extensions of the standard model predict measurable levels of this otherwise rare decay. We reconstruct fully one neutral B meson and seek evidence for the signal decay in the rest of the event. We find no evidence for signal events and obtain B(B-0 ->tau(+)tau(-))< 4.1x10(-3) at the 90% confidence level

    Search for strange-pentaquark production in e(+)e(-) annihilation at root s=10.58 GeV

    Get PDF
    We search for strange-pentaquark states that have been previously reported by other experiments-the Theta(1540)(+), Xi(5)(1860)(--), and Xi(5)(1860)(0)-in 123 fb(-1) of data recorded with the BABAR detector at the PEP-II e(+)e(-) storage ring. We find no evidence for these states and set 95% confidence level upper limits on the number of Theta(1540)(+) and Xi(5)(1860)(--) pentaquarks produced per e(+)e(-) annihilation into q (q) over bar and per Upsilon(4S) decay. For q (q) over bar events the Theta(1540)(+) [Xi(5)(1860)(--)] limit is about 8 [4] times lower than the rates measured for ordinary baryons of similar mass

    Search for the rare decay B-0 ->tau(+)tau(-) at BABAR

    Get PDF
    We present the results of a search for the decay B-0 ->tau(+)tau(-) in a data sample of (232 +/- 3)x10(6) Upsilon(4S)-> BB decays using the BABAR detector. Certain extensions of the standard model predict measurable levels of this otherwise rare decay. We reconstruct fully one neutral B meson and seek evidence for the signal decay in the rest of the event. We find no evidence for signal events and obtain B(B-0 ->tau(+)tau(-))< 4.1x10(-3) at the 90% confidence level

    Measurement of branching fractions and mass spectra of B -> K pi pi gamma (vol 98, art no 211804, 2007)

    Get PDF
    corecore