35 research outputs found

    Nanoscale Mapping of Bromide Segregation on the Cross Sections of 2 Complex Hybrid Perovskite Photovoltaic Films Using Secondary 3 Electron Hyperspectral Imaging in a Scanning Electron Microscope

    Get PDF
    Mixed halide (I/Br) complex organic/inorganic hybrid perovskite materials have attracted much attention recently because of their excellent photovoltaic properties. Although it has been proposed that their stability is linked to the chemical inhomogeneity of I/Br, no direct proof has been offered to date. Here, we report a new method, secondary electron hyperspectral imaging (SEHI), which allows direct imaging of the local variation in Br concentration in mixed halide (I/Br) organic/inorganic hybrid perovskites on a nanometric scale. We confirm the presence of a nonuniform Br distribution with variation in concentration within the grain interiors and boundaries and demonstrate how SEHI in conjunction with low-voltage scanning electron microscopy can enhance the understanding of the fundamental physics and materials science of organic/inorganic hybrid photovoltaics, illustrating its potential for research and development in “real-world” applications

    Life cycle assessment and environmental profile evaluation of lead-free piezoelectrics in comparison with lead zirconate titanate

    Get PDF
    The prohibition of lead in many electronic components and devices due to its toxicity has reinvigorated the race to develop substitutes for lead zirconate titanate (PZT) based mainly on the potassium sodium niobate (KNN) and sodium bismuth titanate (NBT). However, before successful transition from laboratory to market, critical environmental assessment of all aspects of their fabrication and development must be carried out in comparison with PZT. Given the recent findings that KNN is not intrinsically ‘greener’ than PZT, there is a tendency to see NBT as the solution to achieving environmentally lead-free piezoelectrics competitive with PZT. The lower energy consumed by NBT during synthesis results in a lower overall environmental profile compared to both PZT and KNN. However, bismuth and its oxide are mainly the by-product of lead smelting and comparison between NBT and PZT indicates that the environmental profile of bismuth oxide surpasses that of lead oxide across several key indicators, especially climate change, due to additional processing and refining steps which pose extra challenges in metallurgical recovery. Furthermore, bismuth compares unfavourably with lead due to its higher energy cost of recycling. The fact that roughly 90–95% of bismuth is derived as a by-product of lead smelting also constitutes a major concern for future upscaling. As such, NBT and KNN do not offer absolute competitive edge from an environmental perspective in comparison to PZT. The findings in this work have global practical implications for future Restriction of Hazardous Substances (RoHS) legislation for piezoelectric materials and demonstrate the need for a holistic approach to the development of sustainable functional materials

    Patient-specific finite element estimated femur strength as a predictor of the risk of hip fracture: the effect of methodological determinants

    Get PDF
    Summary: A finite element modelling pipeline was adopted to predict femur strength in a retrospective cohort of 100 women. The effects of the imaging protocol and the meshing technique on the ability of the femur strength to classify the fracture and the control groups were analysed. Introduction: The clinical standard to estimate the risk of osteoporotic hip fracture is based on the areal bone mineral density (aBMD). A few retrospective studies have concluded that finite element (FE)-based femoral strength is a better classifier of fracture and control groups than the aBMD, while others could not find significant differences. We investigated the effect of the imaging protocol and of the FE modelling techniques on the discriminatory power of femoral strength. Methods: A retrospective cohort of 100 post-menopausal women (50 with hip fracture, 50 controls) was examined. Each subject received a dual-energy absorptiometry (DXA) exam and a computed tomography (CT) scan of the proximal femur region. Each case was modelled a number of times, using different modelling pipelines, and the results were compared in terms of accuracy in discriminating the fracture and the control cases. The baseline pipeline involved local anatomical orientation and mesh morphing. Revised pipelines involved global anatomical orientation using a full-femur atlas registration and an optimised meshing algorithm. Minimum physiological (MPhyS) and pathological (MPatS) strengths were estimated for each subject. Area under the receiver operating characteristic (ROC) curve (AUC) was calculated to compare the ability of MPhyS, MPatS and aBMD to classify the control and the cases. Results: Differences in the modelling protocol were found to considerably affect the accuracy of the FE predictors. For the most optimised protocol, logistic regression showed aBMD Neck , MPhyS and MPatS to be significantly associated with the facture status, with AUC of 0.75, 0.75 and 0.79, respectively. Conclusion: The study emphasized the necessity of modelling the whole femur anatomy to develop a robust FE-based tool for hip fracture risk assessment. FE-strength performed only slightly better than the aBMD in discriminating the fracture and control cases. Differences between the published studies can be explained in terms of differences in the modelling protocol and cohort design

    Perovskite solar cells: An integrated hybrid lifecycle assessment and review in comparison with other photovoltaic technologies

    Get PDF
    Solar cells are considered as one of the prominent sources of renewable energy suitable for large-scale adoption in a carbon-constrained world and can contribute to reduced reliance on energy imports, whilst improving the security of energy supply. A new arrival in the family of solar cells technologies is the organic-inorganic halide perovskite. The major thrust for endorsing these new solar cells pertains to their potential as an economically and environmentally viable option to traditional silicon-based technology. To verify this assertion, this paper presents a critical review of some existing photovoltaic (PV) technologies in comparison with perovskite-structured solar cells (PSCs), including material and performance parameters, production processes and manufacturing complexity, economics, key technological challenges for further developments and current research efforts. At present, there is limited environmental assessment of PSCs and consequently, a methodologically robust and environmentally expansive lifecycle supply chain assessment of two types of PSC modules A and B is also undertaken within the context of other PV technologies, to assess their potential for environmentally friendly innovation in the energy sector. Module A is based on MAPbX3 perovskite structure while module B is based on CsFAPbX3 with improved stability, reproducibility and high performance efficiency. The main outcomes, presented along with sensitivity analysis, show that PSCs offer more environmentally friendly and sustainable option, with the least energy payback period, as compared to other PV technologies. The review and analysis presented provide valuable insight and guidance in identifying pathways and windows of opportunity for future PV designs towards cleaner and sustainable energy production

    Lead or no lead? Availability, toxicity, sustainability and environmental impact of lead-free perovskite solar cells

    No full text
    Hybrid halide perovskites have taken over the world of new generation photovoltaics (PVs) since their first implementation just a decade ago, thanks to their efficiency comparable to commercial solutions, ease of fabrication, flexibility and versatility. Despite their outstanding performances, the presence of lead represents a severe concern for their future commercialisation, due to its toxicity and associated risks to human health and its environmental impact. Lead-free perovskites offer a potential avenue to circumvent the problem. However, parameters such as material abundance, toxicity and environmental impact of potential lead-substituents are too often neglected. In this review, we put forward a different perspective, focusing on concepts such as cost, availability, sustainability and eco-friendliness required to justify the large-scale use of lead alternatives in the PV industry. Furthermore, comparative case studies with technologies based on lead-containing materials such as lead zirconate titanate, Pb(ZrxTi1-x)O3, also known as PZT, and CdTe solar panels are provided. Finally, it is argued that the advantages of using lead in photovoltaic panels-when including proper encapsulation and recycling-outweigh the risks associated with its manufacturing. This journal i

    NAVIGATION IN ORTHOGNATHIC SURGERY:3D ACCURACY

    No full text
    This article aims to determine the absolute accuracy of maxillary repositioning during orthognathic surgery according to simulation-guided navigation, that is, the combination of navigation and three-dimensional (3D) virtual surgery. We retrospectively studied 15 patients treated for asymmetric dentofacial deformities at the Oral and Maxillofacial Surgery Unit of the S.Orsola-Malpighi University Hospital in Bologna, Italy, from January 2010 to January 2012. Patients were scanned with a cone-beam computed tomography before and after surgery. The virtual surgical simulation was realized with a dedicated software and loaded on a navigation system to improve intraoperative reproducibility of the preoperative planning. We analyzed the outcome following two protocols: (1) planning versus postoperative 3D surface analysis; (2) planning versus postoperative point-based analysis. For 3D surface comparison, the mean Hausdorff distance was measured, and median among cases was 0.99 mm. Median reproducibility\u2009<\u20091\u2009mm was 61.88% and median reproducibility\u2009<\u20092\u2009mm was 85.46%. For the point-based analysis, with sign, the median distance was 0.75\u2009mm in the frontal axis, -0.05\u2009mm in the caudal-cranial axis, -0.35\u2009mm in the lateral axis. In absolute value, the median distance was 1.19\u2009mm in the frontal axis, 0.59\u2009mm in the caudal-cranial axis, and 1.02\u2009mm in the lateral axis. We suggest that simulation-guided navigation makes accurate postoperative outcomes possible for maxillary repositioning in orthognathic surgery, if compared with the surgical computer-designed project realized with a dedicated software, particularly for the vertical dimension, which is the most challenging to manage

    NAVIGATION IN ORTHOGNATHIC SURGERY:3D ACCURACY

    No full text
    This article aims to determine the absolute accuracy of maxillary repositioning during orthognathic surgery according to simulation-guided navigation, that is, the combination of navigation and three-dimensional (3D) virtual surgery. We retrospectively studied 15 patients treated for asymmetric dentofacial deformities at the Oral and Maxillofacial Surgery Unit of the S.Orsola-Malpighi University Hospital in Bologna, Italy, from January 2010 to January 2012. Patients were scanned with a cone-beam computed tomography before and after surgery. The virtual surgical simulation was realized with a dedicated software and loaded on a navigation system to improve intraoperative reproducibility of the preoperative planning. We analyzed the outcome following two protocols: (1) planning versus postoperative 3D surface analysis; (2) planning versus postoperative point-based analysis. For 3D surface comparison, the mean Hausdorff distance was measured, and median among cases was 0.99 mm. Median reproducibility < 1 mm was 61.88% and median reproducibility < 2 mm was 85.46%. For the point-based analysis, with sign, the median distance was 0.75 mm in the frontal axis, -0.05 mm in the caudal-cranial axis, -0.35 mm in the lateral axis. In absolute value, the median distance was 1.19 mm in the frontal axis, 0.59 mm in the caudal-cranial axis, and 1.02 mm in the lateral axis. We suggest that simulation-guided navigation makes accurate postoperative outcomes possible for maxillary repositioning in orthognathic surgery, if compared with the surgical computer-designed project realized with a dedicated software, particularly for the vertical dimension, which is the most challenging to manage
    corecore