    Transverse Incision for Minimally Invasive Plate Osteosynthesis of Osteoporotic Tibial Plateau Fractures

    Get PDF
    Fractures of the tibial plateau frequently require surgical intervention. Open approaches are increasingly being replaced by minimally invasive techniques. Plate fixation may be uni- or bicondylar, and surgical incisions are traditionally orientated in the longitudinal plane. We describe osteoporotic fragility tibial plateau fractures managed with plate fixation applied through minimally invasive transverse incisions. All cases achieved acceptable fracture reduction, restoration of alignment, and timely bone union without infection or wound complications. This technique reduces the risk of wound complications at later arthroplasty, along with the established benefits of current minimally invasive techniques. This is the first report in the literature of the use of transverse incisions for minimally invasive plate fixation of the tibial plateau

    Fractures of the Tibial Plateau Involve Similar Energies as the Tibial Pilon but Greater Articular Surface Involvement

    Get PDF
    Patients with tibial pilon fractures have a higher incidence of post-traumatic osteoarthritis than those with fractures of the tibial plateau. This may indicate that pilon fractures present a greater mechanical insult to the joint than do plateau fractures. We tested the hypothesis that fracture energy and articular fracture edge length, two independent indicators of severity, are higher in pilon than plateau fractures. We also evaluated if clinical fracture classification systems accurately reflect severity. Seventy-five tibial plateau fractures and fifty-two tibial pilon fractures from a multi-institutional study were selected to span the spectrum of severity. Fracture severity measures were calculated using objective CT-based image analysis methods. The ranges of fracture energies measured for tibial plateau and pilon fractures were 3.2 to 33.2 Joules (J) and 3.6 to 32.2 J, respectively, and articular fracture edge lengths were 68.0 to 493.0 mm and 56.1 to 288.6 mm, respectively. There were no differences in the fracture energies between the two fracture types, but plateau fractures had greater articular fracture edge lengths (p<0.001). The clinical fracture classifications generally reflected severity, but there was substantial overlap of fracture severity measures between different classes

    LCP external fixation - External application of an internal fixator: two cases and a review of the literature

    Get PDF
    The locking compression plate (LCP) is an angle-stable fixator intended for intracorporeal application. In selected cases, it can be applied externally in an extracorporeal location to function as a monolateral external fixator. We describe one patient with Schatzker V tibial plateau fracture and one patient with Gustillo IIIB open tibia shaft fracture treated initially with traditional external fixation for whom exchange fixation with externally applied LCPs was performed. The first case went on to bony union while the second case required bone grafting for delayed union. Both patients found that the LCP external fixators facilitated mobilization and were more manageable and aesthetically acceptable than traditional bar-Schanz pin fixators

    Failure of knee osteotomy in a case of neuropathic arthropathy of the knee

    Get PDF
    Neuropathic arthropathy (Charcot’s joint) is a degenerative process that affects peripheral or vertebral joints as a consequence of a disturbance in proprioception and pain perception. The knee is one of the most frequently affected joints, but even when the diagnosis is made at an early stage there is no consensus on the best treatment options. An early diagnosis of neurosyphilis was made in a 55-year-old woman presenting a delayed union of an asymptomatic Schatzker type IV fracture of the proximal tibia. A medial opening wedge tibial osteotomy was performed to achieve fracture healing, to correct the medial depression of the articular surface, and possibly to avoid an early arthritis typical of the disease. To our knowledge, a knee osteotomy has never been reported at an early stage of neuropathic arthropathy. Even though the clinical and radiographic evaluation performed at 4 months follow-up showed a good stage of healing of the osteotomy and no typical features of neuropathic joint degeneration, at 8 months follow-up the knee was markedly deranged

    External versus internal fixation for bicondylar tibial plateau fractures: systematic review and meta-analysis.

    Get PDF
    BACKGROUND: It is uncertain whether external fixation or open reduction internal fixation (ORIF) is optimal for patients with bicondylar tibial plateau fractures. MATERIALS AND METHODS: A systematic review using Ovid MEDLINE, Embase Classic, Embase, AMED, the Cochrane Library, Open Grey, Orthopaedic Proceedings, WHO International Clinical Trials Registry Platform, Current Controlled Trials, US National Institute for Health Trials Registry, and the Cochrane Central Register of Controlled Trials. The search was conducted on 3rd October 2014 and no language limits were applied. Inclusion criteria were all clinical study designs comparing external fixation with open reduction internal fixation of bicondylar tibial plateau fractures. Studies of only one treatment modality were excluded, as were those that included unicondylar tibial plateau fractures. Treatment effects from studies reporting dichotomous outcomes were summarised using odds ratios. Continuous outcomes were converted to standardized mean differences to assess the treatment effect, and inverse variance methods used to combine data. A fixed effect model was used for meta-analyses. RESULTS: Patients undergoing external fixation were more likely to have returned to preinjury activities by six and twelve months (P = 0.030) but not at 24 months follow-up. However, external fixation was complicated by a greater number of infections (OR 2.59, 95 % CI 1.25-5.36, P = 0.01). There were no statistically significant differences in the rates of deep infection, venous thromboembolism, compartment syndrome, or need for re-operation between the two groups. CONCLUSION: Although external fixation and ORIF are associated with different complication profiles, both are acceptable strategies for managing bicondylar tibial plateau fractures

    The accuracy and precision of radiostereometric analysis in monitoring tibial plateau fractures

    Get PDF
    Background and purpose: The application of radiostereometric analysis (RSA) to monitor stability of tibial plateau fractures during healing is both limited and yet to be validated. We therefore evaluated the accuracy and precision of RSA in a tibial plateau fracture model. Methods: Combinations of 3, 6, and 9 markers in a lateral condyle fracture were evaluated with reference to 6 proximal tibial arrangements. Translation and rotation accuracy was assessed with displacement-controlled stages, while precision was assessed with dynamic double examinations. A comparison of error according to marker number and arrangement was completed with 2-way ANOVA models. Results: The results were improved using more tantalum markers in each segment. In the fracture fragment, marker scatter in all axes was achieved by a circumferential arrangement (medial, anterior, and lateral) of the tantalum markers above the fixation devices. Markers placed on either side of the tibial tuberosity and in the medial aspect of the fracture split represented the proximal tibial reference segment best. Using 6 markers with this distribution in each segment, the translation accuracy (root mean square error) was less than 37 μm in all axes. The precision (95% confidence interval) was less than ± 16 μm in all axes in vitro. Rotation, tested around the x-axis, had an accuracy of less than 0.123° and a precision of ± 0.024°. Interpretation: RSA is highly accurate and precise in the assessment of lateral tibial plateau fracture fragment movement. The validation of our center's RSA system provides evidence to support future clinical RSA fracture studies.Lucian B Solomon, Aaron W Stevenson, Stuart A Callary, Thomas R Sullivan, Donald W Howie, and Mellick J Chehad

    Critical review of immediate implant loading

    Full text link
    Background : Implant dentistry has become successful with the discovery of the biological properties of titanium. In the original protocol, studies have advocated a 2-stage surgical protocol for load-free and submerged healing to ensure predictable osseointegration. However, the discomfort, inconvenience, and anxiety associated with waiting period remains a challenge to both patients and clinicians. Hence, loading implant right after placement was attempted and has gained popularity among clinicians. Issues/questions related to this approach remain unanswered. Therefore, it is the purpose of this review article to (1) review and analyze critically the current available literature in the field of immediate implant loading and (2) discuss, based on scientific evidence, factors that may influence this treatment modality. Material and Methods : Literature published over the past 20 years was selected and reviewed. Findings from these studies were discussed and summarized in the tables. The advantages and disadvantages associated with immediate implant loading were analyzed. Factors that may influence the success of immediate implant loading, including patient selection, type of bone quality, required implant length, micro- and macrostructure of the implant, surgical skill, need for achieving primary stability/control of occlusal force, and prosthesis guidelines, were thoroughly reviewed and discussed. Results and Conclusion : Various studies have demonstrated the feasibility and predictability of this technique. However, most of these articles are based on retrospective data or uncontrolled cases. Randomized, prospective, parallel-armed longitudinal human trials are primarily based on short-term results and long-term follow-ups are still scarce in this field. Nonetheless, from available literature, it may be concluded that anatomic locations, implant designs, and restricted prosthetic guidelines are key to ensure successful outcomes. Future studies, preferably randomized, prospective longitudinal studies, are certainly needed before this approach can be widely used. To cite this article: Gapski R, Wang H-L, Mascarenhas P, Lang NP. Critical review of immediate implant loading. Clin. Oral Impl. Res , 14 , 2003; 515–527Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/73058/1/j.1600-0501.2003.00950.x.pd
    corecore