    Impact of operatoŕs experience on peri-procedural outcomes with Watchman FLX: Insights from the FLX-SPA registry

    Get PDF
    Background: The Watchman FLX is a device upgrade of the Watchman 2.5 that incorporates several design enhancements intended to simplify left atrial appendage occlusion (LAAO) and improve procedural outcomes. This study compares peri-procedural results of LAAO with Watchman FLX (Boston Scientific, Marlborough, Massachusetts) in centers with varying degrees of experience with the Watchman 2.5 and Watchman FLX. Methods: Prospective, multicenter, 'real-world' registry including consecutive patients undergoing LAAO with the Watchman FLX at 26 Spanish sites (FLX-SPA registry). Implanting centers were classified according to the center's prior experience with the Watchman 2.5. A further division of centers according to whether or not they had performed ≤ 10 or > 10Watchman FLX implants was prespecified at the beginning of the study. Procedural outcomes of institutions stratified according to their experience with the Watchman 2.5 and FLX devices were compared. Results: 359 patients [mean age 75.5 (SD8.1), CHA2DS2-VASc 4.4 (SD1.4), HAS-BLED 3.8(SD0.9)] were included. Global success rate was 98.6%, successful LAAO with the first selected device size was achieved in 95.5% patients and the device was implanted at first attempt in 78.6% cases. There were only 9(2.5%) major peri-procedural complications. No differences in efficacy or safety results according to the centeŕs previous experience with Watchman 2.5 and procedural volume with Watchman FLX existed. Conclusions: The Watchman FLX attains high procedural success rates with complete LAA sealing in unselected, real-world patients, along with a low incidence of peri-procedural complications, regardless of operatoŕs experience with its previous device iteration or the number of Watchman FLX devices implanted

    Higher COVID-19 pneumonia risk associated with anti-IFN-α than with anti-IFN-ω auto-Abs in children

    Full text link
    We found that 19 (10.4%) of 183 unvaccinated children hospitalized for COVID-19 pneumonia had autoantibodies (auto-Abs) neutralizing type I IFNs (IFN-alpha 2 in 10 patients: IFN-alpha 2 only in three, IFN-alpha 2 plus IFN-omega in five, and IFN-alpha 2, IFN-omega plus IFN-beta in two; IFN-omega only in nine patients). Seven children (3.8%) had Abs neutralizing at least 10 ng/ml of one IFN, whereas the other 12 (6.6%) had Abs neutralizing only 100 pg/ml. The auto-Abs neutralized both unglycosylated and glycosylated IFNs. We also detected auto-Abs neutralizing 100 pg/ml IFN-alpha 2 in 4 of 2,267 uninfected children (0.2%) and auto-Abs neutralizing IFN-omega in 45 children (2%). The odds ratios (ORs) for life-threatening COVID-19 pneumonia were, therefore, higher for auto-Abs neutralizing IFN-alpha 2 only (OR [95% CI] = 67.6 [5.7-9,196.6]) than for auto-Abs neutralizing IFN-. only (OR [95% CI] = 2.6 [1.2-5.3]). ORs were also higher for auto-Abs neutralizing high concentrations (OR [95% CI] = 12.9 [4.6-35.9]) than for those neutralizing low concentrations (OR [95% CI] = 5.5 [3.1-9.6]) of IFN-omega and/or IFN-alpha 2

    Risk profiles and one-year outcomes of patients with newly diagnosed atrial fibrillation in India: Insights from the GARFIELD-AF Registry.

    Get PDF
    BACKGROUND: The Global Anticoagulant Registry in the FIELD-Atrial Fibrillation (GARFIELD-AF) is an ongoing prospective noninterventional registry, which is providing important information on the baseline characteristics, treatment patterns, and 1-year outcomes in patients with newly diagnosed non-valvular atrial fibrillation (NVAF). This report describes data from Indian patients recruited in this registry. METHODS AND RESULTS: A total of 52,014 patients with newly diagnosed AF were enrolled globally; of these, 1388 patients were recruited from 26 sites within India (2012-2016). In India, the mean age was 65.8 years at diagnosis of NVAF. Hypertension was the most prevalent risk factor for AF, present in 68.5% of patients from India and in 76.3% of patients globally (P < 0.001). Diabetes and coronary artery disease (CAD) were prevalent in 36.2% and 28.1% of patients as compared with global prevalence of 22.2% and 21.6%, respectively (P < 0.001 for both). Antiplatelet therapy was the most common antithrombotic treatment in India. With increasing stroke risk, however, patients were more likely to receive oral anticoagulant therapy [mainly vitamin K antagonist (VKA)], but average international normalized ratio (INR) was lower among Indian patients [median INR value 1.6 (interquartile range {IQR}: 1.3-2.3) versus 2.3 (IQR 1.8-2.8) (P < 0.001)]. Compared with other countries, patients from India had markedly higher rates of all-cause mortality [7.68 per 100 person-years (95% confidence interval 6.32-9.35) vs 4.34 (4.16-4.53), P < 0.0001], while rates of stroke/systemic embolism and major bleeding were lower after 1 year of follow-up. CONCLUSION: Compared to previously published registries from India, the GARFIELD-AF registry describes clinical profiles and outcomes in Indian patients with AF of a different etiology. The registry data show that compared to the rest of the world, Indian AF patients are younger in age and have more diabetes and CAD. Patients with a higher stroke risk are more likely to receive anticoagulation therapy with VKA but are underdosed compared with the global average in the GARFIELD-AF. CLINICAL TRIAL REGISTRATION-URL: http://www.clinicaltrials.gov. Unique identifier: NCT01090362

    Correction to: Comparative effectiveness and safety of non-vitamin K antagonists for atrial fibrillation in clinical practice: GLORIA-AF Registry

    No full text
    International audienceIn this article, the name of the GLORIA-AF investigator Anastasios Kollias was given incorrectly as Athanasios Kollias in the Acknowledgements. The original article has been corrected

    Patterns of oral anticoagulant use and outcomes in Asian patients with atrial fibrillation: a post-hoc analysis from the GLORIA-AF Registry

    Get PDF
    Background: Previous studies suggested potential ethnic differences in the management and outcomes of atrial fibrillation (AF). We aim to analyse oral anticoagulant (OAC) prescription, discontinuation, and risk of adverse outcomes in Asian patients with AF, using data from a global prospective cohort study. Methods: From the GLORIA-AF Registry Phase II-III (November 2011-December 2014 for Phase II, and January 2014-December 2016 for Phase III), we analysed patients according to their self-reported ethnicity (Asian vs. non-Asian), as well as according to Asian subgroups (Chinese, Japanese, Korean and other Asian). Logistic regression was used to analyse OAC prescription, while the risk of OAC discontinuation and adverse outcomes were analysed through Cox-regression model. Our primary outcome was the composite of all-cause death and major adverse cardiovascular events (MACE). The original studies were registered with ClinicalTrials.gov, NCT01468701, NCT01671007, and NCT01937377. Findings: 34,421 patients were included (70.0&nbsp;±&nbsp;10.5 years, 45.1% females, 6900 (20.0%) Asian: 3829 (55.5%) Chinese, 814 (11.8%) Japanese, 1964 (28.5%) Korean and 293 (4.2%) other Asian). Most of the Asian patients were recruited in Asia (n&nbsp;=&nbsp;6701, 97.1%), while non-Asian patients were mainly recruited in Europe (n&nbsp;=&nbsp;15,449, 56.1%) and North America (n&nbsp;=&nbsp;8378, 30.4%). Compared to non-Asian individuals, prescription of OAC and non-vitamin K antagonist oral anticoagulant (NOAC) was lower in Asian patients (Odds Ratio [OR] and 95% Confidence Intervals (CI): 0.23 [0.22-0.25] and 0.66 [0.61-0.71], respectively), but higher in the Japanese subgroup. Asian ethnicity was also associated with higher risk of OAC discontinuation (Hazard Ratio [HR] and [95% CI]: 1.79 [1.67-1.92]), and lower risk of the primary composite outcome (HR [95% CI]: 0.86 [0.76-0.96]). Among the exploratory secondary outcomes, Asian ethnicity was associated with higher risks of thromboembolism and intracranial haemorrhage, and lower risk of major bleeding. Interpretation: Our results showed that Asian patients with AF showed suboptimal thromboembolic risk management and a specific risk profile of adverse outcomes; these differences may also reflect differences in country-specific factors. Ensuring integrated and appropriate treatment of these patients is crucial to improve their prognosis. Funding: The GLORIA-AF Registry was funded by Boehringer Ingelheim GmbH