12 research outputs found

    Quality Coding by Neural Populations in the Early Olfactory Pathway: Analysis Using Information Theory and Lessons for Artificial Olfactory Systems

    Get PDF
    In this article, we analyze the ability of the early olfactory system to detect and discriminate different odors by means of information theory measurements applied to olfactory bulb activity images. We have studied the role that the diversity and number of receptor neuron types play in encoding chemical information. Our results show that the olfactory receptors of the biological system are low correlated and present good coverage of the input space. The coding capacity of ensembles of olfactory receptors with the same receptive range is maximized when the receptors cover half of the odor input space - a configuration that corresponds to receptors that are not particularly selective. However, the ensemble’s performance slightly increases when mixing uncorrelated receptors of different receptive ranges. Our results confirm that the low correlation between sensors could be more significant than the sensor selectivity for general purpose chemo-sensory systems, whether these are biological or biomimetic

    Modifying effect of dual antiplatelet therapy on incidence of stent thrombosis according to implanted drug-eluting stent type

    Get PDF
    Aim To investigate the putative modifying effect of dual antiplatelet therapy (DAPT) use on the incidence of stent thrombosis at 3 years in patients randomized to Endeavor zotarolimus-eluting stent (E-ZES) or Cypher sirolimus-eluting stent (C-SES). Methods and results Of 8709 patients in PROTECT, 4357 were randomized to E-ZES and 4352 to C-SES. Aspirin was to be given indefinitely, and clopidogrel/ticlopidine for ≥3 months or up to 12 months after implantation. Main outcome measures were definite or probable stent thrombosis at 3 years. Multivariable Cox regression analysis was applied, with stent type, DAPT, and their interaction as the main outcome determinants. Dual antiplatelet therapy adherence remained the same in the E-ZES and C-SES groups (79.6% at 1 year, 32.8% at 2 years, and 21.6% at 3 years). We observed a statistically significant (P = 0.0052) heterogeneity in treatment effect of stent type in relation to DAPT. In the absence of DAPT, stent thrombosis was lower with E-ZES vs. C-SES (adjusted hazard ratio 0.38, 95% confidence interval 0.19, 0.75; P = 0.0056). In the presence of DAPT, no difference was found (1.18; 0.79, 1.77; P = 0.43). Conclusion A strong interaction was observed between drug-eluting stent type and DAPT use, most likely prompted by the vascular healing response induced by the implanted DES system. These results suggest that the incidence of stent thrombosis in DES trials should not be evaluated independently of DAPT use, and the optimal duration of DAPT will likely depend upon stent type (Clinicaltrials.gov number NCT00476957

    Solid-State, Dye-Labeled DNA Detects Volatile Compounds in the Vapor Phase

    No full text
    This paper demonstrates a previously unreported property of deoxyribonucleic acid—the ability of dye-labeled, solid-state DNA dried onto a surface to detect odors delivered in the vapor phase by changes in fluorescence. This property is useful for engineering systems to detect volatiles and provides a way for artificial sensors to emulate the way cross-reactive olfactory receptors respond to and encode single odorous compounds and mixtures. Recent studies show that the vertebrate olfactory receptor repertoire arises from an unusually large gene family and that the receptor types that have been tested so far show variable breadths of response. In designing biomimetic artificial noses, the challenge has been to generate a similarly large sensor repertoire that can be manufactured with exact chemical precision and reproducibility and that has the requisite combinatorial complexity to detect odors in the real world. Here we describe an approach for generating and screening large, diverse libraries of defined sensors using single-stranded, fluorescent dye–labeled DNA that has been dried onto a substrate and pulsed with brief exposures to different odors. These new solid-state DNA-based sensors are sensitive and show differential, sequence-dependent responses. Furthermore, we show that large DNA-based sensor libraries can be rapidly screened for odor response diversity using standard high-throughput microarray methods. These observations describe new properties of DNA and provide a generalized approach for producing explicitly tailored sensor arrays that can be rationally chosen for the detection of target volatiles with different chemical structures that include biologically derived odors, toxic chemicals, and explosives
    corecore