228 research outputs found

    Fascicles and the interfascicular matrix show adaptation for fatigue resistance in energy storing tendons

    Get PDF
    Tendon is composed of rope-like fascicles, bound together by interfascicular matrix (IFM). Our previous work shows that the IFM is critical for tendon function, facilitating sliding between fascicles to allow tendons to stretch. This function is particularly important in energy storing tendons, which experience extremely high strains during exercise, and therefore require the capacity for considerable inter-fascicular sliding and recoil. This capacity is not required in positional tendons. Whilst we have previously described the quasi-static properties of the IFM, the fatigue resistance of the IFM in functionally distinct tendons remains unknown. We therefore tested the hypothesis that fascicles and IFM in the energy storing equine superficial digital flexor tendon (SDFT) are more fatigue resistant than those in the positional common digital extensor tendon (CDET). Fascicles and IFM from both tendon types were subjected to cyclic fatigue testing until failure, and mechanical properties were calculated. The results demonstrated that both fascicles and IFM from the energy storing SDFT were able to resist a greater number of cycles before failure than those from the positional CDET. Further, SDFT fascicles and IFM exhibited less hysteresis over the course of testing than their counterparts in the CDET. This is the first study to assess the fatigue resistance of the IFM, demonstrating that IFM has a functional role within tendon and contributes significantly to tendon mechanical properties. These data provide important advances into fully characterising tendon structure-function relationships

    Specimen dimensions influence the measurement of material properties in tendon fascicles

    Get PDF
    Stress, strain and modulus are regularly used to characterize material properties of tissue samples. However, when comparing results from different studies it is evident the reported material properties, particularly failure strains, vary hugely. The aim of our study was to characterize how and why specimen length and cross-sectional area (CSA) appear to influence failure stress, strain and modulus in fascicles from two functionally different tendons. Fascicles were dissected from five rat tails and five bovine foot extensors, their diameters determined by a laser micrometer, and loaded to failure at a range of grip-to-grip lengths. Strain to failure significantly decreased with increasing in specimen length in both rat and bovine fascicles, while modulus increased. Specimen length did not influence failure stress in rat tail fascicles, although in bovine fascicles it was significantly lower in the longer 40 mm specimens compared to 5 and 10 mm specimens. The variations in failure strain and modulus with sample length could be predominantly explained by end-effects. However, it was also evident that strain fields along the sample length were highly variable and notably larger towards the ends of the sample than the mid-section even at distances in excess of 5 mm from the gripping points. Failure strain, stress and modulus correlated significantly with CSA at certain specimen lengths. Our findings have implications for the mechanical testing of tendon tissue: while it is not always possible to control for fascicle length and/or CSA, these parameters have to be taken into account when comparing samples of different dimensions

    Fascicles and the interfascicular matrix show decreased fatigue life with ageing in energy storing tendons

    Get PDF
    Tendon is composed of rope-like fascicles bound together by interfascicular matrix (IFM). The IFM is critical for the function of energy storing tendons, facilitating sliding between fascicles to allow these tendons to cyclically stretch and recoil. This capacity is required to a lesser degree in positional tendons. We have previously demonstrated that both fascicles and IFM in energy storing tendons have superior fatigue resistance compared with positional tendons, but the effect of ageing on the fatigue properties of these different tendon subunits has not been determined. Energy storing tendons become more injury-prone with ageing, indicating reduced fatigue resistance, hence we tested the hypothesis that the decline in fatigue life with ageing in energy storing tendons would be more pronounced in the IFM than in fascicles. We further hypothesised that tendon subunit fatigue resistance would not alter with ageing in positional tendons. Fascicles and IFM from young and old energy storing and positional tendons were subjected to cyclic fatigue testing until failure, and mechanical properties were calculated. The results show that both IFM and fascicles from the SDFT exhibit a similar magnitude of reduced fatigue life with ageing. By contrast, the fatigue life of positional tendon subunits was unaffected by ageing. The age-related decline in fatigue life of tendon subunits in energy storing tendons is likely to contribute to the increased risk of injury in aged tendons. Full understanding of the mechanisms resulting in this reduced fatigue life will aid in the development of treatments and interventions to prevent age-related tendinopathy

    The interfascicular matrix enables fascicle sliding and recovery in tendon, and behaves more elastically in energy storing tendons

    Get PDF
    While the predominant function of all tendons is to transfer force from muscle to bone and position the limbs, some tendons additionally function as energy stores, reducing the cost of locomotion. Energy storing tendons experience extremely high strains and need to be able to recoil efficiently for maximum energy storage and return. In the equine forelimb, the energy storing superficial digital flexor tendon (SDFT) has much higher failure strains than the positional common digital extensor tendon (CDET). However, we have previously shown that this is not due to differences in the properties of the SDFT and CDET fascicles (the largest tendon subunits). Instead, there is a greater capacity for interfascicular sliding in the SDFT which facilitates the greater extensions in this particular tendon (Thorpe et al., 2012). In the current study, we exposed fascicles and interfascicular matrix (IFM) from the SDFT and CDET to cyclic loading followed by a test to failure. The results show that IFM mechanical behaviour is not a result of irreversible deformation, but the IFM is able to withstand cyclic loading, and is more elastic in the SDFT than in the CDET. We also assessed the effect of ageing on IFM properties, demonstrating that the IFM is less able to resist repetitive loading as it ages, becoming stiffer with increasing age in the SDFT. These results provide further indications that the IFM is important for efficient function in energy storing tendons, and age-related alterations to the IFM may compromise function and predispose older tendons to injury

    Proteomic Analysis Reveals Age-related Changes in Tendon Matrix Composition, with Age- and Injury-specific Matrix Fragmentation

    Get PDF
    Energy storing tendons, such as the human Achilles and equine superficial digital flexor tendon (SDFT), are highly prone to injury, the incidence of which increases with aging. The cellular and molecular mechanisms that result in increased injury in aged tendons are not well established but are thought to result in altered matrix turnover. However, little attempt has been made to fully characterize the tendon proteome nor determine how the abundance of specific tendon proteins changes with aging and/or injury. The aim of this study was, therefore, to assess the protein profile of normal SDFTs from young and old horses using label-free relative quantification to identify differentially abundant proteins and peptide fragments between age groups. The protein profile of injured SDFTs from young and old horses was also assessed. The results demonstrate distinct proteomic profiles in young and old tendon, with alterations in the levels of proteins involved in matrix organization and regulation of cell tension. Furthermore, we identified several new peptide fragments (neopeptides) present in aged tendons, suggesting that there are age-specific cleavage patterns within the SDFT. Proteomic profile also differed between young and old injured tendon, with a greater number of neopeptides identified in young injured tendon. This study has increased the knowledge of molecular events associated with tendon aging and injury, suggesting that maintenance and repair of tendon tissue may be reduced in aged individuals and may help to explain why the risk of injury increases with aging

    Measurements of the Ratios B(Ds+η+ν)/B(Ds+ϕ+ν){\cal B}(D_s^+\to \eta\ell^+\nu)/{\cal B}(D_s^+\to \phi\ell^+\nu) and B(Ds+η+ν)/B(Ds+ϕ+ν){\cal B}(D_s^+\to \eta'\ell^+\nu)/{\cal B}(D_s^+\to \phi\ell^+\nu)

    Full text link
    Using the CLEO~II detector we measure B(Ds+ηe+ν)/B(Ds+ϕe+ν)=1.24±0.12±0.15{\cal B}(D_s^+\to \eta e^+\nu)/{\cal B}(D_s^+\to \phi e^+\nu) =1.24\pm0.12\pm0.15, B(Ds+ηe+ν)/B(Ds+ϕe+ν)=0.43±0.11±0.07{\cal B}(D_s^+\to \eta' e^+\nu)/{\cal B}(D_s^+\to \phi e^+\nu) =0.43\pm0.11\pm0.07 and B(Ds+ηe+ν)/B(Ds+ηe+ν)=0.35±0.09±0.07{\cal B}(D_s^+\to \eta' e^+\nu)/{\cal B}(D_s^+\to \eta e^+\nu) =0.35\pm0.09\pm0.07. We find the vector to pseudoscalar ratio, B(Ds+ϕe+ν)/B(Ds+(η+η)e+ν)=0.60±0.06±0.06{\cal B}(D_s^+\to \phi e^+\nu)/{\cal B}(D_s^+\to (\eta+\eta') e^+\nu) =0.60\pm0.06\pm0.06, which is similar to the ratio found in non strange DD decays.Comment: 11 page uuencoded postscript file, postscript file also available through http://w4.lns.cornell.edu/public/CLN

    Balanço do nitrogênio e fósforo em solo com cultivo orgânico de hortaliças após a incorporação de biomassa de guandu.

    Get PDF
    Os objetivos deste trabalho foram avaliar os efeitos de faixas de guandu (Cajanus cajan) e da incorporação da biomassa proveniente de sua poda na fertilidade do solo e na produtividade de três hortaliças sob cultivo orgânico. O delineamento usado foi de blocos casualizados completos em esquema de parcelas subsubdivididas com três repetições. As produtividades de beterraba, cenoura e feijão-de-vagem não foram afetadas pelos tratamentos. Nas parcelas onde não houve incorporação da biomassa de guandu, o balanço de nitrogênio no sistema foi negativo, ao passo que com a incorporação, esse balanço foi positivo. Embora tenha ocorrido balanço positivo para o fósforo nas parcelas sem a incorporação de biomassa de guandu, houve um aumento significativo na absorção desse elemento pelas hortaliças quando o material foi incorporado. O sistema de cultivo em aléias de guandu pode representar uma prática vantajosa para os produtores orgânicos, por contribuir na manutenção da fertilidade do solo

    An experimental investigation of the effect of age and sex/gender on pain sensitivity in healthy human participants

    Get PDF
    © 2018 El-Tumi et al. Background: Ageing is associated with alterations of the structure and function of somatosensory tissue that can impact on pain perception. The aim of this study was to investigate the relationship between age and pain sensitivity responses to noxious thermal and mechanical stimuli in healthy adults. Methods: 56 unpaid volunteers (28 women) aged between 20 and 55 years were categorised according to age into one of seven possible groups. The following measurements were taken: thermal detection thresholds, heat pain threshold and tolerance using a TSA-II NeuroSensory Analyzer; pressure pain threshold using a handheld electronic pressure algometer; and cold pressor pain threshold, tolerance, intensity and unpleasantness. Results: There was a positive correlation between heat pain tolerance and age (r = 0.228, P = 0.046), but no statistically significant differences between age groups for cold or warm detection thresholds, or heat pain threshold or tolerance. Forward regression found increasing age to be a predictor of increased pressure pain threshold (B = 0.378, P = 0.002), and sex/gender to be a predictor of cold pressor pain tolerance, with women having lower tolerance than men (B =-0.332, P = 0.006). Conclusion: The findings of this experimental study provide further evidence that pressure pain threshold increases with age and that women have lower thresholds and tolerances to innocuous and noxious thermal stimuli. Significance: The findings demonstrate that variations in pain sensitivity response to experimental stimuli in adults vary according to stimulus modality, age and sex and gender
    corecore