1,062 research outputs found
Use of MMG signals for the control of powered orthotic devices: Development of a rectus femoris measurement protocol
Copyright © 2009 Rehabilitation Engineering and Assistive Technology Society (RESNA). This is an Author's Accepted Manuscript of an article published in Assistive Technology, 21(1), 1 - 12, 2009, copyright Taylor & Francis, available online at: http://www.tandfonline.com/10.1080/10400430902945678.A test protocol is defined for the purpose of measuring rectus femoris mechanomyographic (MMG) signals. The protocol is specified in terms of the following: measurement equipment, signal processing requirements, human postural requirements, test rig, sensor placement, sensor dermal fixation, and test procedure. Preliminary tests of the statistical nature of rectus femoris MMG signals were performed, and Gaussianity was evaluated by means of a two-sided Kolmogorov-Smirnov test. For all 100 MMG data sets obtained from the testing of two volunteers, the null hypothesis of Gaussianity was rejected at the 1%, 5%, and 10%âsignificance levels. Most skewness values were found to be greater than 0.0, while all kurtosis values were found to be greater than 3.0. A statistical convergence analysis also performed on the same 100 MMG data sets suggested that 25 MMG acquisitions should prove sufficient to statistically characterize rectus femoris MMG. This conclusion is supported by the qualitative characteristics of the mean rectus femoris MMG power spectral densities obtained using 25 averages
Actin crosslinker competition and sorting drive emergent GUV size-dependent actin network architecture
The proteins that make up the actin cytoskeleton can self-assemble into a variety of structures. In vitro experiments and coarse-grained simulations have shown that the actin crosslinking proteins α-actinin and fascin segregate into distinct domains in single actin bundles with a molecular size-dependent competition-based mechanism. Here, by encapsulating actin, α-actinin, and fascin in giant unilamellar vesicles (GUVs), we show that physical confinement can cause these proteins to form much more complex structures, including rings and asters at GUV peripheries and centers; the prevalence of different structures depends on GUV size. Strikingly, we found that α-actinin and fascin self-sort into separate domains in the aster structures with actin bundles whose apparent stiffness depends on the ratio of the relative concentrations of α-actinin and fascin. The observed boundary-imposed effect on protein sorting may be a general mechanism for creating emergent structures in biopolymer networks with multiple crosslinkers
The design and characterization of a 300 channel, optimized full-band millimeter filterbank for science with SuperSpec
SuperSpec is an integrated, on-chip spectrometer for millimeter and sub-millimeter astronomy. We report the approach, design optimization, and partial characterization of a 300 channel filterbank covering the 185 to 315 GHz frequency band that targets a resolving power R ~ 310, and fits on a 3.5Ă5.5 cm chip. SuperSpec uses a lens and broadband antenna to couple radiation into a niobium microstrip that feeds a bank of niobium microstrip half-wave resonators for frequency selectivity. Each half-wave resonator is coupled to the inductor of a titanium nitride lumped-element kinetic inductance detector (LEKID) that detects the incident radiation. The device was designed for use in a demonstration instrument at the Large Millimeter Telescope (LMT)
Optimisation of variables for studying dilepton transverse momentum distributions at hadron colliders
In future measurements of the dilepton () transverse momentum,
\Qt, at both the Tevatron and LHC, the achievable bin widths and the ultimate
precision of the measurements will be limited by experimental resolution rather
than by the available event statistics. In a recent paper the variable \at,
which corresponds to the component of \Qt\ that is transverse to the dilepton
thrust axis, has been studied in this regard. In the region, \Qt\ 30 GeV,
\at\ has been shown to be less susceptible to experimental resolution and
efficiency effects than the \Qt. Extending over all \Qt, we now demonstrate
that dividing \at\ (or \Qt) by the measured dilepton invariant mass further
improves the resolution. In addition, we propose a new variable, \phistarEta,
that is determined exclusively from the measured lepton directions; this is
even more precisely determined experimentally than the above variables and is
similarly sensitive to the \Qt. The greater precision achievable using such
variables will enable more stringent tests of QCD and tighter constraints on
Monte Carlo event generator tunes.Comment: 8 pages, 5 figures, 2 table
Full-Array Noise Performance of Deployment-Grade SuperSpec mm-Wave On-Chip Spectrometers
SuperSpec is an on-chip filter bank spectrometer designed for wideband moderate-resolution spectroscopy at millimeter wavelengths, employing TiN kinetic inductance detectors. SuperSpec technology will enable large-format spectroscopic integral field units suitable for high-redshift line intensity mapping and multi-object spectrographs. In previous results, we have demonstrated noise performance in individual detectors suitable for photon noise-limited ground-based observations at excellent mm-wave sites. In these proceedings, we present the noise performance of a full RâŒ275 spectrometer measured using deployment-ready RF hardware and software. We report typical noise equivalent powers through the full device of âŒ3Ă10â»ÂčⶠW Hz^(â1/2) at expected sky loadings, which are photon noise dominated. Based on these results, we plan to deploy a six-spectrometer demonstration instrument to the Large Millimeter Telescope in early 2020
Mouse transcriptome reveals potential signatures of protection and pathogenesis in human tuberculosis
Although mouse infection models have been extensively used to study the host response to Mycobacterium tuberculosis, their validity in revealing determinants of human tuberculosis (TB) resistance and disease progression has been heavily debated. Here, we show that the modular transcriptional signature in the blood of susceptible mice infected with a clinical isolate of M. tuberculosis resembles that of active human TB disease, with dominance of a type I interferon response and neutrophil activation and recruitment, together with a loss in B lymphocyte, natural killer and T cell effector responses. In addition, resistant but not susceptible strains of mice show increased lung B cell, natural killer and T cell effector responses in the lung upon infection. Notably, the blood signature of active disease shared by mice and humans is also evident in latent TB progressors before diagnosis, suggesting that these responses both predict and contribute to the pathogenesis of progressive M. tuberculosis infection
Radiation damage in the LHCb vertex locator
The LHCb Vertex Locator (VELO) is a silicon strip detector designed to reconstruct charged particle trajectories and vertices produced at the LHCb interaction region. During the first two years of data collection, the 84 VELO sensors have been exposed to a range of fluences up to a maximum value of approximately 45 Ă 1012 1 MeV neutron equivalent (1 MeV neq). At the operational sensor temperature of approximately â7 °C, the average rate of sensor current increase is 18 ÎŒA per fbâ1, in excellent agreement with predictions. The silicon effective bandgap has been determined using current versus temperature scan data after irradiation, with an average value of Eg = 1.16±0.03±0.04 eV obtained. The first observation of n+-on-n sensor type inversion at the LHC has been made, occurring at a fluence of around 15 Ă 1012 of 1 MeV neq. The only n+-on-p sensors in use at the LHC have also been studied. With an initial fluence of approximately 3 Ă 1012 1 MeV neq, a decrease in the Effective Depletion Voltage (EDV) of around 25 V is observed. Following this initial decrease, the EDV increases at a comparable rate to the type inverted n+-on-n type sensors, with rates of (1.43±0.16) Ă 10â12 V/ 1 MeV neq and (1.35±0.25) Ă 10â12 V/ 1 MeV neq measured for n+-on-p and n+-on-n type sensors, respectively. A reduction in the charge collection efficiency due to an unexpected effect involving the second metal layer readout lines is observed
Precision luminosity measurements at LHCb
Measuring cross-sections at the LHC requires the luminosity to be determined accurately at each centre-of-mass energy âs. In this paper results are reported from the luminosity calibrations carried out at the LHC interaction point 8 with the LHCb detector for âs = 2.76, 7 and 8 TeV (proton-proton collisions) and for âsNN = 5 TeV (proton-lead collisions). Both the "van der Meer scan" and "beam-gas imaging" luminosity calibration methods were employed. It is observed that the beam density profile cannot always be described by a function that is factorizable in the two transverse coordinates. The introduction of a two-dimensional description of the beams improves significantly the consistency of the results. For proton-proton interactions at âs = 8 TeV a relative precision of the luminosity calibration of 1.47% is obtained using van der Meer scans and 1.43% using beam-gas imaging, resulting in a combined precision of 1.12%. Applying the calibration to the full data set determines the luminosity with a precision of 1.16%. This represents the most precise luminosity measurement achieved so far at a bunched-beam hadron collider
Measurement of the CKM angle Îł from a combination of B±âDh± analyses
A combination of three LHCb measurements of the CKM angle Îł is presented. The decays B±âD K± and
B±âDϱ are used, where D denotes an admixture of D0 and D0 mesons, decaying into K+Kâ, Ï+Ïâ, K±Ïâ, K±ÏâϱÏâ, K0SÏ+Ïâ, or K0S K+Kâ ïŹnal states. All measurements use a dataset corresponding to 1.0 fbâ1 of integrated luminosity. Combining results from B±âD K± decays alone a best-ïŹt value of
Îł =72.0⊠is found, and conïŹdence intervals are set
Îł â [56.4,86.7]⊠at 68% CL,
Îł â [42.6,99.6]⊠at 95% CL.
The best-ïŹt value of Îł found from a combination of results from B±âDϱ decays alone, is Îł =18.9âŠ,
and the conïŹdence intervals
Îł â [7.4,99.2]⊠âȘ [167.9,176.4]⊠at 68% CL
are set, without constraint at 95% CL. The combination of results from B± â D K± and B± â Dϱ
decays gives a best-ïŹt value of Îł =72.6⊠and the conïŹdence intervals
Îł â [55.4,82.3]⊠at 68% CL,
Îł â [40.2,92.7]⊠at 95% CL
are set. All values are expressed modulo 180âŠ, and are obtained taking into account the effect of D0âD0
mixing
Measurement of the ratio of branching fractions BR(B0 -> K*0 gamma)/BR(Bs0 -> phi gamma)
The ratio of branching fractions of the radiative B decays B0 -> K*0 gamma
and Bs0 -> phi gamma has been measured using 0.37 fb-1 of pp collisions at a
centre of mass energy of sqrt(s) = 7 TeV, collected by the LHCb experiment. The
value obtained is BR(B0 -> K*0 gamma)/BR(Bs0 -> phi gamma) = 1.12 +/- 0.08
^{+0.06}_{-0.04} ^{+0.09}_{-0.08}, where the first uncertainty is statistical,
the second systematic and the third is associated to the ratio of fragmentation
fractions fs/fd. Using the world average for BR(B0 -> K*0 gamma) = (4.33 +/-
0.15) x 10^{-5}, the branching fraction BR(Bs0 -> phi gamma) is measured to be
(3.9 +/- 0.5) x 10^{-5}, which is the most precise measurement to date.Comment: 15 pages, 1 figure, 2 table
- âŠ