832 research outputs found

    Scintillator-based ion beam profiler for diagnosing laser-accelerated ion beams

    Get PDF
    Next generation intense, short-pulse laser facilities require new high repetition rate diagnostics for the detection of ionizing radiation. We have designed a new scintillator-based ion beam profiler capable of measuring the ion beam transverse profile for a number of discrete energy ranges. The optical response and emission characteristics of four common plastic scintillators has been investigated for a range of proton energies and fluxes. The scintillator light output (for 1 MeV > Ep < 28 MeV) was found to have a non-linear scaling with proton energy but a linear response to incident flux. Initial measurements with a prototype diagnostic have been successful, although further calibration work is required to characterize the total system response and limitations under the high flux, short pulse duration conditions of a typical high intensity laser-plasma interaction

    Mining and analysis of audiology data to find significant factors associated with tinnitus masker

    Get PDF
    Objectives: The objective of this research is to find the factors associated with tinnitus masker from the literature, and by using the large amount of audiology data available from a large NHS (National Health Services, UK) hearing aid clinic. The factors evaluated were hearing impairment, age, gender, hearing aid type, mould and clinical comments. Design: The research includes literature survey for factors associated with tinnitus masker, and performs the analysis of audiology data using statistical and data mining techniques. Setting: This research uses a large audiology data but it also faced the problem of limited data for tinnitus. Participants: It uses 1,316 records for tinnitus and other diagnoses, and 10,437 records of clinical comments from a hearing aid clinic. Primary and secondary outcome measures: The research is looking for variables associated with tinnitus masker, and in future, these variables can be combined into a single model to develop a decision support system to predict about tinnitus masker for a patient. Results: The results demonstrated that tinnitus maskers are more likely to be fit to individuals with milder forms of hearing loss, and the factors age, gender, type of hearing aid and mould were all found significantly associated with tinnitus masker. In particular, those patients having Age<=55 years were more likely to wear a tinnitus masker, as well as those with milder forms of hearing loss. ITE (in the ear) hearing aids were also found associated with tinnitus masker. A feedback on the results of association of mould with tinnitus masker from a professional audiologist of a large NHS (National Health Services, UK) was also taken to better understand them. The results were obtained with different accuracy for different techniques. For example, the chi-squared test results were obtained with 95% accuracy, for Support and Confidence only those results were retained which had more than 1% Support and 80% Confidence. Conclusions: The variables audiograms, age, gender, hearing aid type and mould were found associated with the choice of tinnitus masker in the literature and by using statistical and data mining techniques. The further work in this research would lead to the development of a decision support system for tinnitus masker with an explanation that how that decision was obtained

    Focused Deterrence and the Prevention of Violent Gun Injuries: Practice, Theoretical Principles, and Scientific Evidence

    Get PDF
    Focused deterrence strategies are a relatively new addition to a growing portfolio of evidence-based violent gun injury prevention practices available to policy makers and practitioners. These strategies seek to change offender behavior by understanding the underlying violence-producing dynamics and conditions that sustain recurring violent gun injury problems and by implementing a blended strategy of law enforcement, community mobilization, and social service actions. Consistent with documented public health practice, the focused deterrence approach identifies underlying risk factors and causes of recurring violent gun injury problems, develops tailored responses to these underlying conditions, and measures the impact of implemented interventions. This article reviews the practice, theoretical principles, and evaluation evidence on focused deterrence strategies. Although more rigorous randomized studies are needed, the available empirical evidence suggests that these strategies generate noteworthy gun violence reduction impacts and should be part of a broader portfolio of violence prevention strategies available to policy makers and practitioners

    Learning auditory space: generalization and long-term effects

    Get PDF
    Background: Previous findings have shown that humans can learn to localize with altered auditory space cues. Here we analyze such learning processes and their effects up to one month on both localization accuracy and sound externalization. Subjects were trained and retested, focusing on the effects of stimulus type in learning, stimulus type in localization, stimulus position, previous experience, externalization levels, and time. Method: We trained listeners in azimuth and elevation discrimination in two experiments. Half participated in the azimuth experiment first and half in the elevation first. In each experiment, half were trained in speech sounds and half in white noise. Retests were performed at several time intervals: just after training and one hour, one day, one week and one month later. In a control condition, we tested the effect of systematic retesting over time with post-tests only after training and either one day, one week, or one month later. Results: With training all participants lowered their localization errors. This benefit was still present one month after training. Participants were more accurate in the second training phase, revealing an effect of previous experience on a different task. Training with white noise led to better results than training with speech sounds. Moreover, the training benefit generalized to untrained stimulus-position pairs. Throughout the post-tests externalization levels increased. In the control condition the long-term localization improvement was not lower without additional contact with the trained sounds, but externalization levels were lower. Conclusion: Our findings suggest that humans adapt easily to altered auditory space cues and that such adaptation spreads to untrained positions and sound types. We propose that such learning depends on all available cues, but each cue type might be learned and retrieved differently. The process of localization learning is global, not limited to stimulus-position pairs, and it differs from externalization processes.Foundation for Science and TechnologyFEDE

    Systematic review of outcome domains and instruments used in clinical trials of tinnitus treatments in adults

    Get PDF
    BACKGROUND: There is no evidence-based guidance to facilitate design decisions for confirmatory trials or systematic reviews investigating treatment efficacy for adults with tinnitus. This systematic review therefore seeks to ascertain the current status of trial designs by identifying and evaluating the reporting of outcome domains and instruments in the treatment of adults with tinnitus. METHODS: Records were identified by searching PubMed, EMBASE CINAHL, EBSCO, and CENTRAL clinical trial registries (ClinicalTrials.gov, ISRCTN, ICTRP) and the Cochrane Database of Systematic Reviews. Eligible records were those published from 1 July 2006 to 12 March 2015. Included studies were those reporting adults aged 18 years or older who reported tinnitus as a primary complaint, and who were enrolled into a randomised controlled trial, a before and after study, a non-randomised controlled trial, a case-controlled study or a cohort study, and written in English. Studies with fewer than 20 participants were excluded. RESULTS: Two hundred and twenty-eight studies were included. Thirty-five different primary outcome domains were identified spanning seven categories (tinnitus percept, impact of tinnitus, co-occurring complaints, quality of life, body structures and function, treatment-related outcomes and unclear or not specified). Over half the studies (55 %) did not clearly define the complaint of interest. Tinnitus loudness was the domain most often reported (14 %), followed by tinnitus distress (7 %). Seventy-eight different primary outcome instruments were identified. Instruments assessing multiple attributes of the impact of tinnitus were most common (34 %). Overall, 24 different patient-reported tools were used, predominantly the Tinnitus Handicap Inventory (15 %). Loudness was measured in diverse ways including a numerical rating scale (8 %), loudness matching (4 %), minimum masking level (1 %) and loudness discomfort level (1 %). Ten percent of studies did not clearly report the instrument used. CONCLUSIONS: Our findings indicate poor appreciation of the basic principles of good trial design, particularly the importance of specifying what aspect of therapeutic benefit is the main outcome. No single outcome was reported in all studies and there was a broad diversity of outcome instruments. PROSPERO REGISTRATION: The systematic review protocol is registered on PROSPERO (International Prospective Register of Systematic Reviews): CRD42015017525. Registered on 12 March 2015 revised on 15 March 2016. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s13063-016-1399-9) contains supplementary material, which is available to authorized users

    The effect of cataract on early stage glaucoma detection using spatial and temporal contrast sensitivity tests

    Get PDF
    Background: To investigate the effect of cataract on the ability of spatial and temporal contrast sensitivity tests used to detect early glaucoma. Methods: Twenty-seven glaucoma subjects with early cataract (mean age 60 ±10.2 years) which constituted the test group were recruited together with twenty-seven controls (cataract only) matched for age and cataract type from a primary eye care setting. Contrast sensitivity to flickering gratings at 20 Hz and stationary gratings with and without glare, were measured for 0.5, 1.5 and 3 cycles per degree (cpd) in central vision. Perimetry and structural measurements with the Heidelberg Retinal Tomograph (HRT) were also performed. Results: After considering the effect of cataract, contrast sensitivity to stationary gratings was reduced in the test group compared with controls with a statistically significant mean difference of 0.2 log units independent of spatial frequency. The flicker test showed a significant difference between test and control group at 1.5 and 3 cpd (p = 0.019 and p = 0.011 respectively). The percentage of glaucoma patients who could not see the temporal modulation was much higher compared with their cataract only counterparts. A significant correlation was found between the reduction of contrast sensitivity caused by glare and the Glaucoma Probability Score (GPS) as measured with the HRT (p<0.005). Conclusions: These findings indicate that both spatial and temporal contrast sensitivity tests are suitable for distinguishing between vision loss as a consequence of glaucoma and vision loss caused by cataract only. The correlation between glare factor and GPS suggests that there may be an increase in intraocular stray light in glaucoma

    The social psychology of protest

    Get PDF
    Social psychological research has taught us a lot about why people protest. This article provides a theoretical and empirical overview. Discussed are grievances, efficacy, identification, emotions and social embeddedness, followed by the most recent approaches, which combine these concepts into dual pathway models. Finally, two future directions are discussed: (1) to shed light on the paradox of persistent participation, and (2) to clarify how perceptions of sociopolitical context affects protest participation. © The Author(s) 2013

    Comparison of the benefits of cochlear implantation versus contra-lateral routing of signal hearing aids in adult patients with single-sided deafness: study protocol for a prospective within-subject longitudinal trial

    Get PDF
    Background Individuals with a unilateral severe-to-profound hearing loss, or single-sided deafness, report difficulty with listening in many everyday situations despite having access to well-preserved acoustic hearing in one ear. The standard of care for single-sided deafness available on the UK National Health Service is a contra-lateral routing of signals hearing aid which transfers sounds from the impaired ear to the non-impaired ear. This hearing aid has been found to improve speech understanding in noise when the signal-to-noise ratio is more favourable at the impaired ear than the non-impaired ear. However, the indiscriminate routing of signals to a single ear can have detrimental effects when interfering sounds are located on the side of the impaired ear. Recent published evidence has suggested that cochlear implantation in individuals with a single-sided deafness can restore access to the binaural cues which underpin the ability to localise sounds and segregate speech from other interfering sounds. Methods/Design The current trial was designed to assess the efficacy of cochlear implantation compared to a contra-lateral routing of signals hearing aid in restoring binaural hearing in adults with acquired single-sided deafness. Patients are assessed at baseline and after receiving a contra-lateral routing of signals hearing aid. A cochlear implant is then provided to those patients who do not receive sufficient benefit from the hearing aid. This within-subject longitudinal design reflects the expected care pathway should cochlear implantation be provided for single-sided deafness on the UK National Health Service. The primary endpoints are measures of binaural hearing at baseline, after provision of a contra-lateral routing of signals hearing aid, and after cochlear implantation. Binaural hearing is assessed in terms of the accuracy with which sounds are localised and speech is perceived in background noise. The trial is also designed to measure the impact of the interventions on hearing- and health-related quality of life. Discussion This multi-centre trial was designed to provide evidence for the efficacy of cochlear implantation compared to the contra-lateral routing of signals. A purpose-built sound presentation system and established measurement techniques will provide reliable and precise measures of binaural hearing. Trial registration Current Controlled Trials http://www.controlled-trials.com/ISRCTN33301739 (05/JUL/2013

    Relationship between Audiometric Slope and Tinnitus Pitch in Tinnitus Patients: Insights into the Mechanisms of Tinnitus Generation

    Get PDF
    BACKGROUND: Different mechanisms have been proposed to be involved in tinnitus generation, among them reduced lateral inhibition and homeostatic plasticity. On a perceptual level these different mechanisms should be reflected by the relationship between the individual audiometric slope and the perceived tinnitus pitch. Whereas some studies found the tinnitus pitch corresponding to the maximum hearing loss, others stressed the relevance of the edge frequency. This study investigates the relationship between tinnitus pitch and audiometric slope in a large sample. METHODOLOGY: This retrospective observational study analyzed 286 patients. The matched tinnitus pitch was compared to the frequency of maximum hearing loss and the edge of the audiogram (steepest hearing loss) by t-tests and correlation coefficients. These analyses were performed for the whole group and for sub-groups (uni- vs. bilateral (117 vs. 338 ears), pure-tone vs. narrow-band (340 vs. 115 ears), and low and high audiometric slope (114 vs. 113 ears)). FINDINGS: For the right ear, tinnitus pitch was in the same range and correlated significantly with the frequency of maximum hearing loss, but differed from and did not correlate with the edge frequency. For the left ear, similar results were found but the correlation between tinnitus pitch and maximum hearing loss did not reach significance. Sub-group analyses (bi- and unilateral, tinnitus character, slope steepness) revealed identical results except for the sub-group with high audiometric slope which revealed a higher frequency of maximum hearing loss as compared to the tinnitus pitch. CONCLUSION: The study-results confirm a relationship between tinnitus pitch and maximum hearing loss but not to the edge frequency, suggesting that tinnitus is rather a fill-in-phenomenon resulting from homeostatic mechanisms, than the result of deficient lateral inhibition. Sub-group analyses suggest that audiometric steepness and the side of affected ear affect this relationship. Future studies should control for these potential confounding factors
    corecore