417 research outputs found

    The correlation between C-reactive protein and toxic granulation of neutrophils in the peripheral blood

    Get PDF
    Background. During inflammation, the serum concentrations of granulocyte colony-stimulating factor (G-CSF), plasma interleukin-6 (IL-6), and C-reactive protein (CRP) increase. A positive correlation between CRP and the percentages of neutrophils exhibiting toxic granulation during inflammation has been demonstrated, and that the fluctuations of CRP and toxic granulation of neutrophils were similar. Objectives. We studied whether grading of toxic granulated neutrophils can be used as a surrogate marker for infection or inflammation, and also be an easier method than previously described methods. Materials and methods. We graded 357 consecutive peripheral blood slides from patients on whom a full blood count with differential count and CRP level was performed, according to intensity of toxic granulation in the neutrophil population, according to a newly proposed grading system. Results. The CRP range was between 1 and 530.3 mg/l. The results confirm the association between a rise in CRP and progressive intensity of toxic granulation in neutrophils in peripheral blood. Kruskal-Wallis equality of populations rank test showed a statistically significant difference between the graded categories (p=0.0001). The Trend test was also statistically significant (p=0.000). Conclusion. The proposed system can be applied to patients with inflammatory or infectious conditions, where grading of toxic granulation of neutrophils can possibly be used as a surrogate marker to assess infection or inflammation and their response to treatment. It may be of particular use in cases where traditional infectious or inflammatory markers cannot be used, owing to inherent problems associated with the respective conditions

    Q(2) dependence of nuclear transparency for exclusive rho(0) production

    Get PDF
    Exclusive coherent and incoherent electroproduction of the rho(0) meson from H-1 and N-14 targets has been studied at the HERMES experiment as a function of coherence length (l(c)), corresponding to the lifetime of hadronic fluctuations of the virtual photon, and squared four-momentum of the virtual photon (-Q(2)). The ratio of N-14 to H-1 cross sections per nucleon, called nuclear transparency, was found to increase (decrease) with increasing l(c) for coherent (incoherent) rho(0) electroproduction. For fixed l(c), a rise of nuclear transparency with Q(2) is observed for both coherent and incoherent rho(0) production, which is in agreement with theoretical calculations of color transparency

    Surveillance or self-surveillance? Behavioral cues can increase the rate of drivers' pro-environmental behavior at a long wait stop

    Get PDF
    By leaving their engines idling for long periods, drivers contribute unnecessarily to air pollution, waste fuel, and produce noise and fumes that harm the environment. Railway level crossings are sites where many cars idle, many times a day. In this research, testing two psychological theories of influence, we examine the potential to encourage drivers to switch off their ignition while waiting at rail crossings. Two field studies presented different signs at a busy rail crossing site with a 2-min average wait. Inducing public self-focus (via a “Watching Eyes” stimulus) was not effective, even when accompanied by a written behavioral instruction. Instead, cueing a private-self focus (“think of yourself”) was more effective, doubling the level of behavioral compliance. These findings confirm the need to engage the self when trying to instigate self-regulatory action, but that cues evoking self-surveillance may sometimes be more effective than cues that imply external surveillance

    Evidence for quark-hadron duality in the proton spin asymmetry A(1)

    Get PDF
    Spin-dependent lepton-nucleon scattering data have been used to investigate the validity of the concept of quark-hadron duality for the spin asymmetry A(1). Longitudinally polarized positrons were scattered off a longitudinally polarized hydrogen target for values of Q(2) between 1.2 and 12 GeV2 and values of W-2 between 1 and 4 GeV2. The average double-spin asymmetry in the nucleon resonance region is found to agree with that measured in deep-inelastic scattering at the same values of the Bjorken scaling variable x. This finding implies that the description of A(1) in terms of quark degrees of freedom is valid also in the nucleon resonance region for values of Q(2) above 1.6 GeV2

    Pregnancy and diabetic ketoacidosis: fetal jeopardy and windows of opportunity

    Get PDF
    BackgroundDiabetic ketoacidosis (DKA) during pregnancy poses significant risks to both the mother and fetus, with an increased risk of fetal demise. Although more prevalent in women with Type I diabetes (T1D); those with Type 2 diabetes (T2D) and gestational diabetes mellitus (GDM) can also develop DKA. A lack of information about DKA during pregnancy exists worldwide, including in South Africa.ObjectiveThis study examined the characteristics and outcomes associated with DKA during pregnancy.MethodsThe study took place between 1 April 2020 and 1 October 2022. Pregnant women with DKA, admitted to Tygerberg Hospital’s Obstetric Critical Care Unit (OCCU) were included. Maternal characteristics, precipitants of DKA, adverse events during treatment, and maternal-fetal outcomes were examined.ResultsThere were 54 episodes of DKA among 47 women. Most DKA’s were mild and occurred in the third trimester. Pregestational diabetes dominated (31/47; 60%), with 47% having T1D and 94% requiring insulin. Seven women (7/47, 15%; T2D:6, T1D:1) had two episodes of DKA during the same pregnancy. Most women (32/47; 68%) were either overweight or obese. Yet, despite the T2D phenotype, biomarkers indicated that auto-immune diabetes was prevalent among women without any prior history of T1D (6/21; 29%). Twelve women (26%) developed gestational hypertension during pregnancy, and 17 (36%) pre-eclampsia. Precipitating causes of DKA included infection (14/54; 26%), insulin disruption (14/54; 26%) and betamethasone administration (10/54; 19%). More than half of the episodes of DKA involved hypokalemia (35/54, 65%) that was associated with fetal death (P=0.042) and hypoglycemia (28/54, 52%). Preterm birth (<37 weeks’ gestation) occurred in 85% of women. No maternal deaths were recorded. A high fetal mortality rate (13/47; 28%) that included 11 spontaneous intrauterine deaths and two medical terminations, was observed.ConclusionWomen with DKA have a high risk of fetal mortality as well as undiagnosed auto-immune diabetes. There is a strong link between maternal hypokalemia and fetal loss, suggesting an opportunity to address management gaps in pregnant women with DKA

    Monte Carlo simulation of virtual Compton scattering below pion threshold

    Get PDF
    This paper describes the Monte Carlo simulation developed specifically for the VCS experiments below pion threshold that have been performed at MAMI and JLab. This simulation generates events according to the (Bethe-Heitler + Born) cross section behaviour and takes into account all relevant resolution-deteriorating effects. It determines the `effective' solid angle for the various experimental settings which are used for the precise determination of photon electroproduction absolute cross section.Comment: 24 pages, 6 figures, to be published in Nuclear Instruments and Methods in Physics Research, A One author adde

    The HERMES Dual-Radiator Ring Imaging Cerenkov Detector

    Full text link
    The construction and use of a dual radiator Ring Imaging Cerenkov(RICH) detector is described. This instrument was developed for the HERMES experiment at DESY which emphasizes measurements of semi-inclusive deep-inelastic scattering. It provides particle identification for pions, kaons, and protons in the momentum range from 2 to 15 GeV, which is essential to these studies. The instrument uses two radiators, C4F10, a heavy fluorocarbon gas, and a wall of silica aerogel tiles. The use of aerogel in a RICH detector has only recently become possible with the development of clear, large homogeneous and hydrophobic aerogel. A lightweight mirror was constructed using a newly perfected technique to make resin-coated carbon-fiber surfaces of optical quality. The photon detector consists of 1934 photomultiplier tubes for each detector half, held in a soft steel matrix to provide shielding against the residual field of the main spectrometer magnet.Comment: 25 pages, 23 figure
    • …
    corecore