162 research outputs found
Recommended from our members
Results from the STAR TPC system test
A system test of various components of the Solenoidal Tracker at RHIC (STAR) detector, operating in concern, has recently come on-line. Communication between a major sub-detector, a sector of the Time Projection Chamber (TPC), and the trigger, data acquisition and slow controls systems has been established, enabling data from cosmic ray muons to be collected. First results from an analysis of the TPC data are presented. These include measurements of system noise, electronic parameters such as amplifier gains and pedestal values, and tracking resolution for cosmic ray muons and laser induced ionization tracks. A discussion on the experience gained in integrating the different components for the system test is also given
A Readout System for the STAR Time Projection Chamber
We describe the readout electronics for the STAR Time Projection Chamber. The
system is made up of 136,608 channels of waveform digitizer, each sampling 512
time samples at 6-12 Mega-samples per second. The noise level is about 1000
electrons, and the dynamic range is 800:1, allowing for good energy loss
() measurement for particles with energy losses up to 40 times minimum
ionizing. The system is functioning well, with more than 99% of the channels
working within specifications.Comment: 22 pages + 8 separate figures; 2 figures are .jpg photos to appear in
Nuclear Instruments and Method
Dielectron Cross Section Measurements in Nucleus-Nucleus Reactions at 1.0 A GeV
We present measured dielectron production cross sections for Ca+Ca, C+C,
He+Ca, and d+Ca reactions at 1.0 A GeV. Statistical uncertainties and
systematic effects are smaller than in previous DLS nucleus-nucleus data. For
pair mass < 0.35 GeV/c2 : 1) the Ca+Ca cross section is larger than the
previous DLS measurement and current model results, 2) the mass spectra suggest
large contributions from pi0 and eta Dalitz decays, and 3) dsigma/dM is
proportional to ApAt. For M > 0.5 GeV/c2 the Ca+Ca to C+C cross section ratio
is significantly larger than the ratio of ApAt values.Comment: Submitted to Physical Review Letters. Further analysis information
will be posted on our web pages -- http://macdls.lbl.gov Figure 1 has been
redrawn to make more legible. Text modified to support redrawn figur
The STAR Time Projection Chamber: A Unique Tool for Studying High Multiplicity Events at RHIC
The STAR Time Projection Chamber (TPC) is used to record collisions at the
Relativistic Heavy Ion Collider (RHIC). The TPC is the central element in a
suite of detectors that surrounds the interaction vertex. The TPC provides
complete coverage around the beam-line, and provides complete tracking for
charged particles within +- 1.8 units of pseudo-rapidity of the center-of-mass
frame. Charged particles with momenta greater than 100 MeV/c are recorded.
Multiplicities in excess of 3,000 tracks per event are routinely reconstructed
in the software. The TPC measures 4 m in diameter by 4.2 m long, making it the
largest TPC in the world.Comment: 28 pages, 11 figure
Inclusive Dielectron Cross Sections in p+p and p+d Interactions at Beam Energies from 1.04 to 4.88 GeV
Measurements of dielectron production in p+p and p+d collisions with beam
kinetic energies from 1.04 to 4.88 GeV are presented. The differential cross
section is presented as a function of invariant pair mass, transverse momentum,
and rapidity. The shapes of the mass spectra and their evolution with beam
energy provide information about the relative importance of the various
dielectron production mechanisms in this energy regime. The p+d to p+p ratio of
the dielectron yield is also presented as a function of invariant pair mass,
transverse momentum, and rapidity. The shapes of the transverse momentum and
rapidity spectra from the p+d and p+p systems are found to be similar to one
another for each of the beam energies studied. The beam energy dependence of
the integrated cross sections is also presented.Comment: 15 pages and 16 figure
Multiplicity distribution and spectra of negatively charged hadrons in Au+Au collisions at sqrt(s_nn) = 130 GeV
The minimum bias multiplicity distribution and the transverse momentum and
pseudorapidity distributions for central collisions have been measured for
negative hadrons (h-) in Au+Au interactions at sqrt(s_nn) = 130 GeV. The
multiplicity density at midrapidity for the 5% most central interactions is
dNh-/deta|_{eta = 0} = 280 +- 1(stat)+- 20(syst), an increase per participant
of 38% relative to ppbar collisions at the same energy. The mean transverse
momentum is 0.508 +- 0.012 GeV/c and is larger than in central Pb+Pb collisions
at lower energies. The scaling of the h- yield per participant is a strong
function of pt. The pseudorapidity distribution is almost constant within
|eta|<1.Comment: 6 pages, 3 figure
Water-loss (intracellular) dehydration assessed using urinary tests, how well do they work? Diagnostic accuracy in older people
Background: Water-loss dehydration (hypertonic, hyperosmotic or intra-cellular dehydration) is due to insufficient fluid intake and distinct from hypovolemia due to excess fluid losses. It is associated with poor health outcomes such as disability and mortality in older people. Urine specific gravity (USG), color and urine osmolality have been widely advocated for screening for dehydration in older adults. Objective: To assess the diagnostic accuracy of urinary measures to screen for water-loss dehydration in older people.Design: This was a diagnostic accuracy study of people aged ≥65years taking part in the Dehydration Recognition In our Elders (DRIE, living in long-term care) or Dietary Strategies for Healthy Ageing in Europe (NU-AGE, living in the community) studies. The reference standard was serum osmolality, index tests included USG, urine color, osmolality, cloudiness, additional dipstick measures, ability to provide a urine sample, and volume of a random urine sample. Minimum useful diagnostic accuracy was set at sensitivity and specificity ≥70% or receiver operating characteristics plot area under the curve ≥0.70. Results: DRIE participants (67% women, mean age 86 years, n=162) had more limited cognitive and functional abilities than NU-AGE participants (64% women, mean age 70 years, n=151). 19% of DRIE and 22% of NU-AGE participants were dehydrated (serum osmolality >300mOsm/kg). Neither USG nor any other potential urinary tests were usefully diagnostic for water-loss dehydration. Conclusions: Although USG, urine color and urinary osmolality have been widely advocated for screening for dehydration in older adults, we show in the largest study to date that their diagnostic accuracy is too low to be useful and these measures should not be used to indicate hydration status in older people (either alone or as part of a wider tranche of tests). There is a need to develop simple, inexpensive and non-invasive tools for the assessment of dehydration in older people
Pion Interferometry of GeV Au+Au Collisions at RHIC
Two-pion correlation functions in Au+Au collisions at
GeV have been measured by the STAR (Solenoidal Tracker at RHIC) detector. The
source size extracted by fitting the correlations grows with event multiplicity
and decreases with transverse momentum. Anomalously large sizes or emission
durations, which have been suggested as signals of quark-gluon plasma formation
and rehadronization, are not observed. The HBT parameters display a weak energy
dependence over a broad range in .Comment: 6 pages, 3 figures; accepted to Phys Rev Lett; data tables available
at STAR web site http://www.star.bnl.gov/ Click on "Publications" in menu ba
Identified Particle Elliptic Flow in Au+Au Collisions at GeV}
We report first results on elliptic flow of identified particles at
mid-rapidity in Au+Au collisions at GeV using the STAR
TPC at RHIC. The elliptic flow as a function of transverse momentum and
centrality differs significantly for particles of different masses. This
dependence can be accounted for in hydrodynamic models, indicating that the
system created shows a behavior consistent with collective hydrodynamical flow.
The fit to the data with a simple model gives information on the temperature
and flow velocities at freeze-out.Comment: REVTeX style include
- …