419 research outputs found

    Mechano‐Optical Characterization of Extrusion Flow Instabilities in Styrene‐Butadiene Rubbers: Investigating the Influence of Molecular Properties and Die Geometry

    Get PDF
    The extrusion flow instabilities of two commercial styrene-butadiene rubbers are investigated as they vary in isomer content (1,4-cis, 1,4-trans, and 1,2 con- formation) of the butadiene monomer and the molecular architecture (linear, branched). The investigated samples have similar multimodal molecular weight distribution. Two geometries of extrusion dies, slit and round capillary, are compared in terms of the type and the spatial characteristics of the flow instabilities. The latter are quantified using three methods: a highly pressure sensitive slit die, online and offline optical analysis. The highly pressure- sensitive slit die has three piezoelectric pressure transducers (Δt ≈ 10−3 s and Δp ≈ 10−5 bar) placed along the die length. The characteristic frequency (fChar.) of the flow instabilities follows a power law behavior as a function of shear\ua0rate to a 0.5 power for both materials, f Char. ∝ γ app.. A qualitative model is used\ua0to predict the spatial characteristic wavelength (λ) of the flow instabilities from round capillary to slit dies and vice versa. Slip velocities (Vs) are used to quantify the slippage at slit and round capillary dies as well

    Simulations of extensional flow in microrheometric devices

    Get PDF
    We present a detailed numerical study of the flow of a Newtonian fluid through microrheometric devices featuring a sudden contraction–expansion. This flow configuration is typically used to generate extensional deformations and high strain rates. The excess pressure drop resulting from the converging and diverging flow is an important dynamic measure to quantify if the device is intended to be used as a microfluidic extensional rheometer. To explore this idea, we examine the effect of the contraction length, aspect ratio and Reynolds number on the flow kinematics and resulting pressure field. Analysis of the computed velocity and pressure fields show that, for typical experimental conditions used in microfluidic devices, the steady flow is highly three-dimensional with open spiraling vortical structures in the stagnant corner regions. The numerical simulations of the local kinematics and global pressure drop are in good agreement with experimental results. The device aspect ratio is shown to have a strong impact on the flow and consequently on the excess pressure drop, which is quantified in terms of the dimensionless Couette and Bagley correction factors. We suggest an approach for calculating the Bagley correction which may be especially appropriate for planar microchannels

    Defining Metrics for Short Term Success After LVAD Implant: An Analysis of the Society of Thoracic Surgeons Intermacs Registry

    Get PDF
    Purpose: While clinical trials evaluating left ventricular assist device (LVAD) technology typically use composite outcomes to assess efficacy, composite outcomes including patient reported outcomes (PROs) have not been utilized as benchmarks for LVAD implant center performance improvement initiatives or quality ranking. The objective of the study was to assess the feasibility of generating a patient composite outcome measure including PROs from a real world registry. Methods: Short term (ST, 180 days) adverse events (AEs) and mortality were tallied for Intermacs patients undergoing LVAD implant between 1/2012 and 12/2019. ST postoperative events included mortality on first device and frequencies of stroke, reoperation (device malfunction/other), right heart failure (RHF), prolonged respiratory failure, and/or dialysis on first device. Logistic regression was used to generate odds ratios for mortality for each AE. Separately, the EuroQOL visual analog scale (VAS) was assessed at baseline and 180 days in ST survivors. Results: Of 20,115 patients, 37% suffered at least one event, most commonly death, reoperation and stroke (Table, column A). Stroke, prolonged respiratory failure, and dialysis attributed the most to ST mortality (Table, column B). Of the 16725 patients alive at 180 days, 43% completed a VAS with 82.0% showing VAS improvement. Renal failure and RHF contributed most to failure to improve VAS (Figure). Conclusion: Assessment of a ST composite outcome metric after LVAD implant from a real world data source is feasible but limited by incomplete PRO reporting. ST adverse events display differential effects on mortality and PROs that can be used in development of global rank outcome scores. While reoperation is common, stroke, prolonged respiratory failure and renal failure conferred highest risks of ST deaths within Intermacs. Assessment of PROs should become a priority for LVAD centers to allow the field to generate a complete assessment of patient-centered outcomes

    Hadron Energy Reconstruction for the ATLAS Calorimetry in the Framework of the Non-parametrical Method

    Get PDF
    This paper discusses hadron energy reconstruction for the ATLAS barrel prototype combined calorimeter (consisting of a lead-liquid argon electromagnetic part and an iron-scintillator hadronic part) in the framework of the non-parametrical method. The non-parametrical method utilizes only the known e/he/h ratios and the electron calibration constants and does not require the determination of any parameters by a minimization technique. Thus, this technique lends itself to an easy use in a first level trigger. The reconstructed mean values of the hadron energies are within ±1\pm 1% of the true values and the fractional energy resolution is [(58±3)/E+(2.5±0.3)[(58\pm3)% /\sqrt{E}+(2.5\pm0.3)%]\oplus (1.7\pm0.2)/E. The value of the e/he/h ratio obtained for the electromagnetic compartment of the combined calorimeter is 1.74±0.041.74\pm0.04 and agrees with the prediction that e/h>1.7e/h > 1.7 for this electromagnetic calorimeter. Results of a study of the longitudinal hadronic shower development are also presented. The data have been taken in the H8 beam line of the CERN SPS using pions of energies from 10 to 300 GeV.Comment: 33 pages, 13 figures, Will be published in NIM

    The driver landscape of sporadic chordoma

    Get PDF
    Chordoma is a malignant, often incurable bone tumour showing notochordal differentiation. Here, we defined the somatic driver landscape of 104 cases of sporadic chordoma. We reveal somatic duplications of the notochordal transcription factor brachyury (T) in up to 27% of cases. These variants recapitulate the rearrangement architecture of the pathogenic germline duplications of T that underlie familial chordoma. In addition, we find potentially clinically actionable PI3K signalling mutations in 16% of cases. Intriguingly, one of the most frequently altered genes, mutated exclusively by inactivating mutation, was LYST (10%), which may represent a novel cancer gene in chordoma

    Thinking outside the curve, part I: modeling birthweight distribution

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Greater epidemiologic understanding of the relationships among fetal-infant mortality and its prognostic factors, including birthweight, could have vast public health implications. A key step toward that understanding is a realistic and tractable framework for analyzing birthweight distributions and fetal-infant mortality. The present paper is the first of a two-part series that introduces such a framework.</p> <p>Methods</p> <p>We propose describing a birthweight distribution via a normal mixture model in which the number of components is determined from the data using a model selection criterion rather than fixed <it>a priori</it>.</p> <p>Results</p> <p>We address a number of methodological issues, including how the number of components selected depends on the sample size, how the choice of model selection criterion influences the results, and how estimates of mixture model parameters based on multiple samples from the same population can be combined to produce confidence intervals. As an illustration, we find that a 4-component normal mixture model reasonably describes the birthweight distribution for a population of white singleton infants born to heavily smoking mothers. We also compare this 4-component normal mixture model to two competitors from the existing literature: a contaminated normal model and a 2-component normal mixture model. In a second illustration, we discover that a 6-component normal mixture model may be more appropriate than a 4-component normal mixture model for a general population of black singletons.</p> <p>Conclusions</p> <p>The framework developed in this paper avoids assuming the existence of an interval of birthweights over which there are no compromised pregnancies and does not constrain birthweights within compromised pregnancies to be normally distributed. Thus, the present framework can reveal heterogeneity in birthweight that is undetectable via a contaminated normal model or a 2-component normal mixture model.</p
    corecore