860 research outputs found

    Novel Silicon n-in-p Pixel Sensors for the future ATLAS Upgrades

    Full text link
    In view of the LHC upgrade phases towards HL-LHC the ATLAS experiment plans to upgrade the Inner Detector with an all silicon system. The n-in-p silicon technology is a promising candidate for the pixel upgrade thanks to its radiation hardness and cost effectiveness, that allow for enlarging the area instrumented with pixel detectors. We present the characterization and performance of novel n-in-p planar pixel sensors produced by CiS (Germany) connected by bump bonding to the ATLAS readout chip FE-I3. These results are obtained before and after irradiation up to a fluence of 10^16 1-MeV n_eq/cm^2, and prove the operability of this kind of sensors in the harsh radiation environment foreseen for the pixel system at HL-LHC. We also present an overview of the new pixel production, which is on-going at CiS for sensors compatible with the new ATLAS readout chip FE-I4.Comment: Preprint submitted to NIM-A Proceedings (Elba 2012

    Status of a DEPFET pixel system for the ILC vertex detector

    Get PDF
    We have developed a prototype system for the ILC vertex detector based on DEPFET pixels. The system operates a 128x64 matrix (with ~35x25 square micron large pixels) and uses two dedicated microchips, the SWITCHER II chip for matrix steering and the CURO II chip for readout. The system development has been driven by the final ILC requirements which above all demand a detector thinned to 50 micron and a row wise read out with line rates of 20MHz and more. The targeted noise performance for the DEPFET technology is in the range of ENC=100 e-. The functionality of the system has been demonstrated using different radioactive sources in an energy range from 6 to 40keV. In recent test beam experiments using 6GeV electrons, a signal-to-noise ratio of S/N~120 has been achieved with present sensors being 450 micron thick. For improved DEPFET systems using 50 micron thin sensors in future, a signal-to-noise of 40 is expected.Comment: Invited poster at the International Symposium on the Development of Detectors for Particle, AstroParticle and Synchrotron Radiation Experiments, Stanford CA (SNIC06) 6 pages, 12 eps figure

    Optimum spectral window for imaging of art with optical coherence tomography

    Get PDF
    Optical Coherence Tomography (OCT) has been shown to have potential for important applications in the field of art conservation and archaeology due to its ability to image subsurface microstructures non-invasively. However, its depth of penetration in painted objects is limited due to the strong scattering properties of artists’ paints. VIS-NIR (400 nm – 2400 nm) reflectance spectra of a wide variety of paints made with historic artists’ pigments have been measured. The best spectral window with which to use optical coherence tomography (OCT) for the imaging of subsurface structure of paintings was found to be around 2.2 μm. The same spectral window would also be most suitable for direct infrared imaging of preparatory sketches under the paint layers. The reflectance spectra from a large sample of chemically verified pigments provide information on the spectral transparency of historic artists’ pigments/paints as well as a reference set of spectra for pigment identification. The results of the paper suggest that broadband sources at ~2 microns are highly desirable for OCT applications in art and potentially material science in general

    CIX - A Detector for Spectral Enhanced X-ray Imaging by Simultaneous Counting and Integrating

    Full text link
    A hybrid pixel detector based on the concept of simultaneous charge integration and photon counting will be presented. The second generation of a counting and integrating X-ray prototype CMOS chip (CIX) has been operated with different direct converting sensor materials (CdZnTe and CdTe) bump bonded to its 8x8 pixel matrix. Photon counting devices give excellent results for low to medium X-ray fluxes but saturate at high rates while charge integration allows the detection of very high fluxes but is limited at low rates by the finite signal to noise ratio. The combination of both signal processing concepts therefore extends the resolvable dynamic range of the X-ray detector. In addition, for a large region of the dynamic range, where counter and integrator operate simultaneously, the mean energy of the detected X-ray spectrum can be calculated. This spectral information can be used to enhance the contrast of the X-ray image. The advantages of the counting and integrating signal processing concept and the performance of the imaging system will be reviewed. The properties of the system with respect to dynamic range and sensor response will be discussed and examples of imaging with additional spectral information will be presented.Comment: 12 pages, 14 figures, SPIE Medical Imaging Conference, San Diego, 200

    Analysis of 19 Minerals and Cortisol in Red Deer Hair in Two Different Areas of the Stelvio National Park: A Preliminary Study

    Get PDF
    The aim of the study was to perform an investigation on the concentration of 19 minerals and cortisol in red deer (Cervuselaphus) hair, a matrix that is easy to collect with non-invasive and painless sampling, able to represent an integrative values of long-term substance concentrations, and able to give useful information, also when performed on dead animals, given its extreme stability over time. In the study thirty-five animals were included, coming from two different sides of a valley in the Stelvio National Park, where official water analysis had pointed out elevated concentrations of As in one of the two orographic sides. Hair cortisol concentrations were measured using a RIA(Radio Immuno Assay), while minerals were detected using ICP-MS (Inductively Coupled Plasma- Mass Spectrometry). Results showed a negative relationship between cortisol and some mineral concentrations (Li, Co, As, Cd, Cr and Tl) and significant differences in some mineral concentrations between park areas (Al, Co, Cu, Cd and Ni). As, Cr and cortisol differences approached statistical significance. This preliminary study represents a step forward in the study of wildlife allostatic load and a valid method for applications in wildlife management programs, in environmental studies and in public health programs

    Transceiver ASIC in HVCMOS Technology for 3D Ultrasound Computer Tomography

    Get PDF
    Abstract3D Ultrasound Computer Tomography (3D USCT) is an imaging method for the early de-tection of breast cancer. It provides three-dimensional multimodal images of the breast. Thenew 3D USCT device developed currently at Karlsruhe Institute of Technology containsmore than two thousand ultrasound transducers placed in a water-filled aperture where thepatient submerges one breast. The ultrasound transducers are grouped as transducer arraysystems (TAS) of 18 receiver (RX) and transmitter (TX) elements. The transducer front-end electronics contain high-voltage (HV) and low-voltage (LV) amplifiers and switcheswhich are implemented as an application-specific integrated circuit (ASIC). This contribu-tion presents a patented mixed signal, multichannel, transceiver ASIC developed in a com-mercial 350 nm high-voltage CMOS (HV-CMOS) process. The HV-CMOS process provideslow-voltage and high-voltage transistors that can be combined on the same substrate. TheHV transistors can sustain voltages up to 120 V

    Radiation-hard active pixel sensors for HL-LHC detector upgrades based on HV-CMOS technology

    Get PDF
    Luminosity upgrades are discussed for the LHC (HL-LHC) which would make updates to the detectors necessary, requiring in particular new, even more radiation-hard and granular, sensors for the inner detector region. A proposal for the next generation of inner detectors is based on HV-CMOS: a new family of silicon sensors based on commercial high-voltage CMOS technology, which enables the fabrication of part of the pixel electronics inside the silicon substrate itself. The main advantages of this technology with respect to the standard silicon sensor technology are: low material budget, fast charge collection time, high radiation tolerance, low cost and operation at room temperature. A traditional readout chip is still needed to receive and organize the data from the active sensor and to handle high-level functionality such as trigger management. HV-CMOS has been designed to be compatible with both pixel and strip readout. In this paper an overview of HV2FEI4, a HV-CMOS prototype in 180 nm AMS technology, will be given. Preliminary results after neutron and X-ray irradiation are shown

    Angiographic outcome of coronary artery bypass grafts: Radial Artery Database International Alliance

    Get PDF
    BACKGROUND: We used a large patient-level dataset including six angiographic randomized trials (RCTs) on coronary artery bypass conduits to explore incidence and determinants of coronary graft failure. METHODS: Patient-level angiographic data of six RCTs comparing long-term outcomes of the radial artery and other conduits were joined. Primary outcome was graft occlusion at maximum follow-up. The analysis was divided as follows: 1) left anterior descending coronary (LAD) distribution, 2) non-LAD distribution (circumflex and right coronary artery). To identify predictors of graft occlusion, mixed model multivariable Cox regression including all baseline characteristics with stratification by individual trials was used. RESULTS: 1091 patients and 2281 grafts were included (921 left internal mammary arteries, 74 right internal mammary arteries, 710 radial artery and 576 saphenous veins; all left internal mammary arteries were used on the LAD, the other conduits were used on the non-LAD distribution; mean angiographic follow up: 65±29 months). Occlusion rate was 2.3%, 13.5%, 9.4%, 17.5% for the left internal mammary arteries, right internal mammary arteries, radial artery and saphenous veins, respectively. At multivariable analysis type of conduit used, age, female gender, left ventricular ejection fraction<50% and use of the Y graft were significantly associated with graft occlusion in the non-LAD distribution. CONCLUSIONS: Our analyses showed that failure of the left internal mammary arteries to LAD bypass is a very uncommon event. For the non-LAD distribution, the non-use of radial artery, age, female gender, left ventricular ejection fraction<50% and use of the Y graft configuration were significantly associated with mid-term graft failure
    • …
    corecore