30 research outputs found

    Discovery of the 151^{151}Eu α\alpha decay

    Full text link
    We report on the first compelling observation of α\alpha decay of 151^{151}Eu to the ground state of 147^{147}Pm. The measurement was performed using a 6.15 g Li6_6Eu(BO3_3)3_3 crystal operated as a scintillating bolometer. The Q-value and half-life measured are: Q = 1948.9±6.9(stat.)±5.1(syst.)\pm 6.9(stat.) \pm 5.1(syst.) keV, and T1/2=(4.62±0.95(stat.)±0.68(syst.))×1018_{1/2}=\left( 4.62\pm0.95(stat.)\pm0.68(syst.)\right) \times 10^{18} y . The half-life prediction of nuclear theory using the Coulomb and proximity potential model are in good agreement with this experimental result

    Validation of techniques to mitigate copper surface contamination in CUORE

    Get PDF
    In this article we describe the background challenges for the CUORE experiment posed by surface contamination of inert detector materials such as copper, and present three techniques explored to mitigate these backgrounds. Using data from a dedicated test apparatus constructed to validate and compare these techniques we demonstrate that copper surface contamination levels better than 10E-07 - 10E-08 Bq/cm2 are achieved for 238U and 232Th. If these levels are reproduced in the final CUORE apparatus the projected 90% C.L. upper limit on the number of background counts in the region of interest is 0.02-0.03 counts/keV/kg/y depending on the adopted mitigation technique.Comment: 10 pages, 6 figures, 6 table

    Search for 14.4 keV solar axions from M1 transition of Fe-57 with CUORE crystals

    Full text link
    We report the results of a search for axions from the 14.4 keV M1 transition from Fe-57 in the core of the sun using the axio-electric effect in TeO2 bolometers. The detectors are 5x5x5 cm3 crystals operated at about 10 mK in a facility used to test bolometers for the CUORE experiment at the Laboratori Nazionali del Gran Sasso in Italy. An analysis of 43.65 kg d of data was made using a newly developed low energy trigger which was optimized to reduce the detectors energy threshold. An upper limit of 0.63 c kg-1 d-1 was established at 95% C.L.. From this value, a lower bound at 95% C.L. was placed on the Peccei-Quinn energy scale of fa >= 0.76 10**6 GeV for a value of S=0.55 for the flavor-singlet axial vector matrix element. Bounds are given for the interval 0.15 < S < 0.55.Comment: 14 pages, 6 figures, submitted to JCA

    Valutazione di Health Technology Assessment del sistema di sanificazione biologico a base di probiotici del genere Bacillus (PCHS)

    Get PDF
    Le infezioni correlate all’assistenza: priorità per la salute pubblica Epidemiologia delle infezioni correlate all’assistenza in Italia e loro impatto per la salute pubblica Sistemi di sanificazione attualmente disponibili in Italia Il Probiotic Cleaning Hygiene System (PCHS): caratteristiche della tecnologia, aspetti di efficacia e sicurezza Un sistema di sanificazione a base di probiotici per la riduzione delle infezioni correlate all’assistenza e la resistenza antimicrobica: analisi dell’impatto sul budget Impatto ambientale per la salute pubblica degli attuali sistemi di sanificazione di ambienti/superfici in setting assistenziale e comunitario e potenziali benefici dei nuovi sistemi innovativi Analisi delle principali raccomandazioni nazionali su sanificazione e disinfezione degli ambienti sanitari Valutazione etica dell’utilizzo del Probiotic Cleaning Hygiene System (PCHS) in Italia Elementi chiave per il processo decisional

    The commissioning of the CUORE experiment: the mini-tower run

    Get PDF
    CUORE is a ton-scale experiment approaching the data taking phase in Gran Sasso National Laboratory. Its primary goal is to search for the neutrinoless double-beta decay in 130Te using 988 crystals of tellurim dioxide. The crystals are operated as bolometers at about 10 mK taking advantage of one of the largest dilution cryostat ever built. Concluded in March 2016, the cryostat commissioning consisted in a sequence of cool down runs each one integrating new parts of the apparatus. The last run was performed with the fully configured cryostat and the thermal load at 4 K reached the impressive mass of about 14 tons. During that run the base temperature of 6.3 mK was reached and maintained for more than 70 days. An array of 8 crystals, called mini-tower, was used to check bolometers operation, readout electronics and DAQ. Results will be presented in terms of cooling power, electronic noise, energy resolution and preliminary background measurements

    Results from the Cuore Experiment

    Get PDF
    The Cryogenic Underground Observatory for Rare Events (CUORE) is the first bolometric experiment searching for neutrinoless double beta decay that has been able to reach the 1-ton scale. The detector consists of an array of 988 TeO2 crystals arranged in a cylindrical compact structure of 19 towers, each of them made of 52 crystals. The construction of the experiment was completed in August 2016 and the data taking started in spring 2017 after a period of commissioning and tests. In this work we present the neutrinoless double beta decay results of CUORE from examining a total TeO2 exposure of 86.3kg yr, characterized by an effective energy resolution of 7.7 keV FWHM and a background in the region of interest of 0.014 counts/ (keV kg yr). In this physics run, CUORE placed a lower limit on the decay half- life of neutrinoless double beta decay of 130Te > 1.3.1025 yr (90% C. L.). Moreover, an analysis of the background of the experiment is presented as well as the measurement of the 130Te 2vo3p decay with a resulting half- life of T2 2. [7.9 :- 0.1 (stat.) :- 0.2 (syst.)] x 10(20) yr which is the most precise measurement of the half- life and compatible with previous results

    Initial performance of the CUORE-0 experiment

    Get PDF
    CUORE-0 is a cryogenic detector that uses an array of tellurium dioxide bolometers to search for neutrinoless double-beta decay of ^{130}Te. We present the first data analysis with 7.1 kg y of total TeO_2 exposure focusing on background measurements and energy resolution. The background rates in the neutrinoless double-beta decay region of interest (2.47 to 2.57 MeV) and in the {\alpha} background-dominated region (2.70 to 3.90 MeV) have been measured to be 0.071 \pm 0.011 and 0.019 \pm 0.002 counts/keV/kg/y, respectively. The latter result represents a factor of 6 improvement from a predecessor experiment, Cuoricino. The results verify our understanding of the background sources in CUORE-0, which is the basis of extrapolations to the full CUORE detector. The obtained energy resolution (full width at half maximum) in the region of interest is 5.7 keV. Based on the measured background rate and energy resolution in the region of interest, CUORE-0 half-life sensitivity is expected to surpass the observed lower bound of Cuoricino with one year of live time.Comment: 8 pages, 5 figures, version 2 as published in Eur. Phys. J.

    Neutrinoless double-beta decay search with CUORE and CUORE-0 experiments

    Get PDF
    The Cryogenic Underground Observatory for Rare Events (CUORE) is an upcoming experiment designed to search for the neutrinoless double-beta decays. Observation of the process would unambiguously establish that neutrinos are Majorana particles and provide information on their absolute mass scale hierarchy. CUORE is now under construction and will consist of an array of 988 TeO2 crystal bolometers operated at 10 mK, but the first tower (CUORE-0) is already taking data. The experimental techniques used will be presented as well as the preliminary CUORE-0 results. The current status of the full-mass experiment and its expected sensitivity will then be discussed

    Il pensiero giuridico di Piero Calamandrei

    No full text
    La tesi analizza il pensiero giuridico di Calamandrei: in particolare le posizioni più importanti da lui sostenute durante i lavori dell'Assemblea costituente. Con riferimento alla struttura costituzionale della Repubblica, Calamandrei propugnava l'adozione di una Repubblica presidenziale sul modello americano, al fine di rafforzare l'autorità del capo del governo e rimediare alla frammentazione partitica. In tema di laicità dello Stato e con riferimento ai rapporti tra Stato e Chiesa cattolica, si oppose all'inserimento in Costituzione di quello che diverrà l'art. 7 Costituzione. Sempre su tale tema, importanti furono i suoi scritti sulla libertà della scuola e dell'insegnamento. S'impegnò per garantire l'indipendenza della magistratura e liberare la giustizia dalle influenze esercitate dalla politica. Più complessa la posizione che assunse in ordine all'introduzione nella Costituzione dei diritti sociali accanto ai diritti di libertà. Si analizzano le ragioni per cui egli, che credeva profondamente nella giustizia sociale, voleva porre i diritti sociali al di fuori della Carta costituzionale. Si esamina il pensiero del giurista sul principio di legalità a cui egli faceva riferimento costante nei suoi scritti ed interventi. Si riporta la denuncia che Calamandrei fece allo stato delle carceri e s'espone la sua posizione sulla pena di morte

    Health professionals of prevention in Italy. The value of expertise during COVID-19 pandemic

    No full text
    There are 22 different degree courses related to the Healthcare Professions in the Italian university system, which are divided into four areas. "Healthcare Professions of Prevention" is the fourth area and it is fundamental for the National Health Service. In particular, in this pandemic emergency situation, the contribution of the Prevention Technicians in the Environment and Workplaces (PTEW) is essential in the field and workplace management. The "Core Competence" of the PTEW is to carry out, with professional autonomy, prevention, verification, and control activities in the field of hygiene and safety of living and working environments. In the hospitals, the indications provided by national and/or regional authorities are implemented through procedures on good hygiene practices developed by PTEW (e.g., hand hygiene, "respiratory tract hygiene," environmental hygiene, social distancing, and use of Personal Protective Equipment). One of the activities is the health surveillance on the field by population monitoring. The protocols foreseen for the "in-flow of workers" involve a wider control between social life and work. The PTEW will use a Check List divided into 3 macro phases: Entry, Activity Context, and Exit, defining each behavior of the work phases with a constant presence of verification of the procedures. The PTEW will be a Leader on the topics of education, training, and persuasion, considering a New Principle that "transforms the worker as active part in the application and diffusion of the safety measures"
    corecore