1,230 research outputs found

    Skin necrosis in smoking patients receiving partial breast irradiation: two case reports

    Get PDF
    Partial breast irradiation has become an increasingly popular mode of treatment after excisional biopsy to treat early stage invasive breast cancer. Its main advantage is that treatment can be delivered in five days rather than 30, as is standard for whole breast irradiation. Early reports suggest good to excellent cosmesis in the vast majority of subjects. Herein we report two cases of skin necrosis in women with Stage 1 breast cancer who smoked before and after partial breast irradiation

    Recovery of renal function in dialysis patients

    Get PDF
    BACKGROUND: Although recovery of renal functions in dialysis dependent patients is estimated to be greater than 1%, there are no indicators that actually suggest such revival of renal function. Residual renal function in dialysis patients is unreliable and seldom followed. Therefore renal recovery (RR) in dialysis dependent patients may remain unnoticed. We present a group of dialysis dependent patients who regained their renal functions. The aim of this project is to determine any indicators that may identify the recovery of renal functions in dialysis dependent patients. METHODS: All the discharges from the chronic dialysis facilities were identified. Among these discharges deaths, transplants, voluntary withdrawals and transfers either to another modality or another dialysis facility were excluded in order to isolate the patients with RR. The dialysis flow sheets and medical records of these patients were subsequently reviewed. RESULTS: Eight patients with a mean age of 53.8 Âą 6.7 years (Âą SEM) were found to have RR. Dialysis was initiated due to uremic symptoms in 6 patients and fluid overload in the remaining two. The patients remained dialysis dependent for 11.1 Âą 4.2 months. All these patients had good urine output and 7 had symptoms related to dialysis. Their mean pre-initiation creatinine and BUN levels were 5.21 Âą 0.6 mg/dl and 72.12 Âą 11.12 mg/dl, respectively. Upon discontinuation, they remained dialysis free for 19.75 Âą 5.97 months. The mean creatinine and BUN levels after cessation of dialysis were 2.85 Âą 0.57 mg/dl and 29.62 Âą 5.26 mg/dl, respectively, while the mean creatinine clearance calculated by 24-hour urine collection was 29.75 Âą 4.78 ml/min. One patient died due to HIV complications. One patient resumed dialysis after nine months. Remaining continue to enjoy a dialysis free life. CONCLUSION: RR must be considered in patients with good urine output and unresolved acute renal failure. Dialysis intolerance may be an indicator of RR among such patients

    Surgical perspectives from a prospective, nonrandomized, multicenter study of breast conserving surgery and adjuvant electronic brachytherapy for the treatment of breast cancer

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Accelerated partial breast irradiation (APBI) may be used to deliver radiation to the tumor bed post-lumpectomy in eligible patients with breast cancer. Patient and tumor characteristics as well as the lumpectomy technique can influence patient eligibility for APBI. This report describes a lumpectomy procedure and examines patient, tumor, and surgical characteristics from a prospective, multicenter study of electronic brachytherapy.</p> <p>Methods</p> <p>The study enrolled 65 patients of age 45-84 years with ductal carcinoma or ductal carcinoma in situ, and 44 patients, who met the inclusion and exclusion criteria, were treated with APBI using the Axxent<sup>ÂŽ </sup>electronic brachytherapy system following lumpectomy. The prescription dose was 34 Gy in 10 fractions over 5 days.</p> <p>Results</p> <p>The lumpectomy technique as described herein varied by site and patient characteristics. The balloon applicator was implanted by the surgeon (91%) or a radiation oncologist (9%) during or up to 61 days post-lumpectomy (mean 22 days). A lateral approach was most commonly used (59%) for insertion of the applicator followed by an incision site approach in 27% of cases, a medial approach in 5%, and an inferior approach in 7%. A trocar was used during applicator insertion in 27% of cases. Local anesthetic, sedation, both or neither were administered in 45%, 2%, 41% and 11% of cases, respectively, during applicator placement. The prescription dose was delivered in 42 of 44 treated patients.</p> <p>Conclusions</p> <p>Early stage breast cancer can be treated with breast conserving surgery and APBI using electronic brachytherapy. Treatment was well tolerated, and these early outcomes were similar to the early outcomes with iridium-based balloon brachytherapy.</p

    A search for the decay modes B+/- to h+/- tau l

    Get PDF
    We present a search for the lepton flavor violating decay modes B+/- to h+/- tau l (h= K,pi; l= e,mu) using the BaBar data sample, which corresponds to 472 million BBbar pairs. The search uses events where one B meson is fully reconstructed in one of several hadronic final states. Using the momenta of the reconstructed B, h, and l candidates, we are able to fully determine the tau four-momentum. The resulting tau candidate mass is our main discriminant against combinatorial background. We see no evidence for B+/- to h+/- tau l decays and set a 90% confidence level upper limit on each branching fraction at the level of a few times 10^-5.Comment: 15 pages, 7 figures, submitted to Phys. Rev.

    Evidence for an excess of B -> D(*) Tau Nu decays

    Get PDF
    Based on the full BaBar data sample, we report improved measurements of the ratios R(D(*)) = B(B -> D(*) Tau Nu)/B(B -> D(*) l Nu), where l is either e or mu. These ratios are sensitive to new physics contributions in the form of a charged Higgs boson. We measure R(D) = 0.440 +- 0.058 +- 0.042 and R(D*) = 0.332 +- 0.024 +- 0.018, which exceed the Standard Model expectations by 2.0 sigma and 2.7 sigma, respectively. Taken together, our results disagree with these expectations at the 3.4 sigma level. This excess cannot be explained by a charged Higgs boson in the type II two-Higgs-doublet model. We also report the observation of the decay B -> D Tau Nu, with a significance of 6.8 sigma.Comment: Expanded section on systematics, text corrections, improved the format of Figure 2 and included the effect of the change of the Tau polarization due to the charged Higg

    Search for the decay modes D^0 → e^+e^-, D^0 → μ^+μ^-, and D^0 → e^±μ∓

    Get PDF
    We present searches for the rare decay modes D^0→e^+e^-, D^0→μ^+μ^-, and D^0→e^±μ^∓ in continuum e^+e^-→cc events recorded by the BABAR detector in a data sample that corresponds to an integrated luminosity of 468  fb^(-1). These decays are highly Glashow–Iliopoulos–Maiani suppressed but may be enhanced in several extensions of the standard model. Our observed event yields are consistent with the expected backgrounds. An excess is seen in the D^0→μ^+μ^- channel, although the observed yield is consistent with an upward background fluctuation at the 5% level. Using the Feldman–Cousins method, we set the following 90% confidence level intervals on the branching fractions: B(D^0→e^+e^-)<1.7×10^(-7), B(D^0→μ^+μ^-) within [0.6,8.1]×10^(-7), and B(D^0→e^±μ^∓)<3.3×10^(-7)

    Observation and study of baryonic B decays: B -> D(*) p pbar, D(*) p pbar pi, and D(*) p pbar pi pi

    Get PDF
    We present a study of ten B-meson decays to a D(*), a proton-antiproton pair, and a system of up to two pions using BaBar's data set of 455x10^6 BBbar pairs. Four of the modes (B0bar -> D0 p anti-p, B0bar -> D*0 p anti-p, B0bar -> D+ p anti-p pi-, B0bar -> D*+ p anti-p pi-) are studied with improved statistics compared to previous measurements; six of the modes (B- -> D0 p anti-p pi-, B- -> D*0 p anti-p pi-, B0bar -> D0 p anti-p pi- pi+, B0bar -> D*0 p anti-p pi- pi+, B- -> D+ p anti-p pi- pi-, B- -> D*+ p anti-p pi- pi-) are first observations. The branching fractions for 3- and 5-body decays are suppressed compared to 4-body decays. Kinematic distributions for 3-body decays show non-overlapping threshold enhancements in m(p anti-p) and m(D(*)0 p) in the Dalitz plots. For 4-body decays, m(p pi-) mass projections show a narrow peak with mass and full width of (1497.4 +- 3.0 +- 0.9) MeV/c2, and (47 +- 12 +- 4) MeV/c2, respectively, where the first (second) errors are statistical (systematic). For 5-body decays, mass projections are similar to phase space expectations. All results are preliminary.Comment: 28 pages, 90 postscript figures, submitted to LP0

    Study of the reaction e^{+}e^{-} -->J/psi\pi^{+}\pi^{-} via initial-state radiation at BaBar

    Get PDF
    We study the process e+e−→J/ψπ+π−e^+e^-\to J/\psi\pi^{+}\pi^{-} with initial-state-radiation events produced at the PEP-II asymmetric-energy collider. The data were recorded with the BaBar detector at center-of-mass energies 10.58 and 10.54 GeV, and correspond to an integrated luminosity of 454 fb−1\mathrm{fb^{-1}}. We investigate the J/ψπ+π−J/\psi \pi^{+}\pi^{-} mass distribution in the region from 3.5 to 5.5 GeV/c2\mathrm{GeV/c^{2}}. Below 3.7 GeV/c2\mathrm{GeV/c^{2}} the ψ(2S)\psi(2S) signal dominates, and above 4 GeV/c2\mathrm{GeV/c^{2}} there is a significant peak due to the Y(4260). A fit to the data in the range 3.74 -- 5.50 GeV/c2\mathrm{GeV/c^{2}} yields a mass value 4244±54244 \pm 5 (stat) ±4 \pm 4 (syst)MeV/c2\mathrm{MeV/c^{2}} and a width value 114−15+16114 ^{+16}_{-15} (stat)±7 \pm 7(syst)MeV\mathrm{MeV} for this state. We do not confirm the report from the Belle collaboration of a broad structure at 4.01 GeV/c2\mathrm{GeV/c^{2}}. In addition, we investigate the π+π−\pi^{+}\pi^{-} system which results from Y(4260) decay

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
    • …
    corecore