2,191 research outputs found

    STARD for Abstracts: Essential items for reporting diagnostic accuracy studies in journal or conference abstracts

    Get PDF
    Many abstracts of diagnostic accuracy studies are currently insufficiently informative. We extended the STARD (Standards for Reporting Diagnostic Accuracy) statement by developing a list of essential items that authors should consider when reporting diagnostic accuracy studies in journal or conference abstracts. After a literature review of published guidance for reporting biomedical studies, we identified 39 items potentially relevant to report in an abstract. We then selected essential items through a two round web based survey among the 85 members of the STARD Group, followed by discussions within an executive committee. Seventy three STARD Group members responded (86%), with 100% completion rate. STARD for Abstracts is a list of 11 quintessential items, to be reported in every abstract of a diagnostic accuracy study. We provide examples of complete reporting, and developed template text for writing informative abstract

    A comparison of course-related stressors in undergraduate problem-based learning (PBL) versus non-PBL medical programmes

    Get PDF
    Background: Medical students report high levels of stress related to their medical training as well as to other personal and financial factors. The aim of this study is to investigate whether there are differences in course-related stressors reported by medical students on undergraduate problem-based learning (PBL) and non-PBL programmes in the UK. Method: A cross-sectional study of second-year medical students in two UK medical schools (one PBL and one non-PBL programme) was conducted. A 16-question self-report questionnaire, derived from the Perceived Medical Student Stress Scale and the Higher Education Stress Inventory, was used to measure course-related stressors. Following univariate analysis of each stressor between groups, multivariate logistic regression was used to determine which stressors were the best predictors of each course type, while controlling for socio-demographic differences between the groups. Results: A total of 280 students responded. Compared to the non-PBL students (N = 197), the PBL students (N = 83) were significantly more likely to agree that: they did not know what the faculty expected of them (Odds Ratio (OR) = 0.38, p = 0.03); there were too many small group sessions facilitated only by students resulting in an unclear curriculum (OR = 0.04, p < 0.0001); and that there was a lack of opportunity to explore academic subjects of interest (OR = 0.40, p = 0.02). They were significantly more likely to disagree that: there was a lack of encouragement from teachers (OR = 3.11, p = 0.02); and that the medical course fostered a sense of anonymity and feelings of isolation amongst students (OR = 3.42, p = 0.008). Conclusion: There are significant differences in the perceived course-related stressors affecting medical students on PBL and non-PBL programmes. Course designers and student support services should therefore tailor their work to minimise, or help students cope with, the specific stressors on each course type to ensure optimum learning and wellbeing among our future doctors

    Ultrafast nonlocal control of spontaneous emission

    Full text link
    Solid-state cavity quantum electrodynamics systems will form scalable nodes of future quantum networks, allowing the storage, processing and retrieval of quantum bits, where a real-time control of the radiative interaction in the cavity is required to achieve high efficiency. We demonstrate here the dynamic molding of the vacuum field in a coupled-cavity system to achieve the ultrafast nonlocal modulation of spontaneous emission of quantum dots in photonic crystal cavities, on a timescale of ~200 ps, much faster than their natural radiative lifetimes. This opens the way to the ultrafast control of semiconductor-based cavity quantum electrodynamics systems for application in quantum interfaces and to a new class of ultrafast lasers based on nano-photonic cavities.Comment: 15 pages, 4 figure

    ArteFill® Permanent Injectable for Soft Tissue Augmentation: I. Mechanism of Action and Injection Techniques

    Get PDF
    After more than 25 years of research and development, in October 2006 ArteFill® became the first and only permanent injectable wrinkle filler to receive FDA approval. ArteFill is a third-generation polymeric microsphere-based filler, following its predecessor Artecoll®, which was marketed outside the United States between 1994 and 2006. ArteFill is approved for the correction of nasolabial folds and has been used in over 15,000 patients since its U.S. market introduction in February 2007. No serious side effects have been reported to date according to the FDA’s MAUDE reporting database. ArteFill consists of polymethylmethacrylate (PMMA) microspheres (20% by volume), 30–50 μm in diameter, suspended in 3.5% bovine collagen solution (80% by volume) and 0.3% lidocaine. The collagen carrier is absorbed within 1 month after injection and completely replaced by the patient’s own connective tissue within 3 months. Each cc of ArteFill contains approximately six million microspheres and histological studies have shown that long-term wrinkle correction consists of 80% of the patient’s own connective tissue and 20% microspheres. The standard injection technique is subdermal tunneling that delivers a strand of ArteFill at the dermal–subdermal junction. This strand beneath a wrinkle or fold acts like a support structure that protects against further wrinkling and allows the diminished thickness of the dermis to recover to its original thickness

    Life satisfaction and resilience in medical school – a six-year longitudinal, nationwide and comparative study

    Get PDF
    BACKGROUND: This study examined the relationship between life satisfaction among medical students and a basic model of personality, stress and coping. Previous studies have shown relatively high levels of distress, such as symptoms of depression and suicidal thoughts in medical undergraduates. However despite the increased focus on positive psychological health and well-being during the past decades, only a few studies have focused on life satisfaction and coping in medical students. This is the first longitudinal study which has identified predictors of sustained high levels of life satisfaction among medical students. METHODS: This longitudinal, nationwide questionnaire study examined the course of life satisfaction during medical school, compared the level of satisfaction of medical students with that of other university students, and identified resilience factors. T-tests were used to compare means of life satisfaction between and within the population groups. K-means cluster analyses were applied to identify subgroups among the medical students. Analysis of Variance (ANOVA) and logistic regression analyses were used to compare the subgroups. RESULTS: Life satisfaction decreased during medical school. Medical students were as satisfied as other students in the first year of study, but reported less satisfaction in their graduation year. Medical students who sustained high levels of life satisfaction perceived medical school as interfering less with their social and personal life, and were less likely to use emotion focused coping, such as wishful thinking, than their peers. CONCLUSION: Medical schools should encourage students to spend adequate time on their social and personal lives and emphasise the importance of health-promoting coping strategies

    A Light Stop with Flavor in Natural SUSY

    Full text link
    The discovery of a SM-like Higgs boson near 125 GeV and the flavor texture of the Standard Model motivate the investigation of supersymmetric quiver-like BSM extensions. We study the properties of such a minimal class of models which deals naturally with the SM parameters. Considering experimental bounds as well as constraints from flavor physics and Electro-Weak Precision Data, we find the following. In a self-contained minimal model - including the full dynamics of the Higgs sector - top squarks below a TeV are in tension with b->s{\gamma} constraints. Relaxing the assumption concerning the mass generation of the heavy Higgses, we find that a stop not far from half a TeV is allowed. The models have some unique properties, e.g. an enhancement of the h-> b\bar{b},\tau\bar{{\tau}} decays relative to the h->\gamma{\gamma} one, a gluino about 3 times heavier than the stop, an inverted hierarchy of about 3-20 between the squarks of the first two generations and the stop, relatively light Higgsino neutralino or stau NLSP, as well as heavy Higgses and a W' which may be within reach of the LHC.Comment: LaTeX, 22 pages, 4 figures; V2: references adde

    Mental Health Diagnoses and Utilization of VA Non-Mental Health Medical Services Among Returning Iraq and Afghanistan Veterans

    Get PDF
    Over 35% of returned Iraq and Afghanistan veterans in VA care have received mental health diagnoses; the most prevalent is post-traumatic stress disorder (PTSD). Little is known about these patients’ use of non-mental health medical services and the impact of mental disorders on utilization. To compare utilization across three groups of Iraq and Afghanistan veterans: those without mental disorders, those with mental disorders other than PTSD, and those with PTSD. National, descriptive study of 249,440 veterans newly utilizing VA healthcare between October 7, 2001 and March 31, 2007, followed until March 31, 2008. We used ICD9-CM diagnostic codes to classify mental health status. We compared utilization of outpatient non-mental health services, primary care, medical subspecialty, ancillary services, laboratory tests/diagnostic procedures, emergency services, and hospitalizations during veterans’ first year in VA care. Results were adjusted for demographics and military service and VA facility characteristics. Veterans with mental disorders had 42–146% greater utilization than those without mental disorders, depending on the service category (all P &lt; 0.001). Those with PTSD had the highest utilization in all categories: 71–170% greater utilization than those without mental disorders (all P &lt; 0.001). In adjusted analyses, compared with veterans without mental disorders, those with mental disorders other than PTSD had 55% higher utilization of all non-mental health outpatient services; those with PTSD had 91% higher utilization. Female sex and lower rank were also independently associated with greater utilization. Veterans with mental health diagnoses, particularly PTSD, utilize significantly more VA non-mental health medical services. As more veterans return home, we must ensure resources are allocated to meet their outpatient, inpatient, and emergency needs

    Validating the Eating Disorder Inventory-3 (EDI-3): A Comparison Between 561 Female Eating Disorders Patients and 878 Females from the General Population

    Get PDF
    The Eating Disorder Inventory (EDI) is used worldwide in research and clinical work. The 3rd version (EDI-3) has been used in recent research, yet without any independent testing of its psychometric properties. The aim of the present study was twofold: 1) to establish national norms and to compare them with the US and international norms, and 2) to examine the factor structure, the internal consistency, the sensitivity and the specificity of subscale scores. Participants were Danish adult female patients (N = 561) from a specialist treatment centre and a control group (N = 878) was women selected from the Danish Civil Registration system. Small but significant differences were found between Danish and international, as well as US norms. Overall, the factor structure was confirmed, the internal consistency of the subscales was satisfactory, the discriminative validity was good, and sensitivity and specificity were excellent. The implications from these results are discussed

    An affordable, quality-assured community-based system for high-resolution entomological surveillance of vector mosquitoes that reflects human malaria infection risk patterns.

    Get PDF
    ABSTRACT: BACKGROUND: More sensitive and scalable entomological surveillance tools are required to monitor low levels of transmission that are increasingly common across the tropics, particularly where vector control has been successful. A large-scale larviciding programme in urban Dar es Salaam, Tanzania is supported by a community-based (CB) system for trapping adult mosquito densities to monitor programme performance. Methodology An intensive and extensive CB system for routine, longitudinal, programmatic surveillance of malaria vectors and other mosquitoes using the Ifakara Tent Trap (ITT-C) was developed in Urban Dar es Salaam, Tanzania, and validated by comparison with quality assurance (QA) surveys using either ITT-C or human landing catches (HLC), as well as a cross-sectional survey of malaria parasite prevalence in the same housing compounds. RESULTS: Community-based ITT-C had much lower sensitivity per person-night of sampling than HLC (Relative Rate (RR) [95% Confidence Interval (CI)] = 0.079 [0.051, 0.121], P < 0.001 for Anopheles gambiae s.l. and 0.153 [0.137, 0.171], P < 0.001 for Culicines) but only moderately differed from QA surveys with the same trap (0.536 [0.406,0.617], P = 0.001 and 0.747 [0.677,0.824], P < 0.001, for An. gambiae or Culex respectively). Despite the poor sensitivity of the ITT per night of sampling, when CB-ITT was compared with QA-HLC, it proved at least comparably sensitive in absolute terms (171 versus 169 primary vectors caught) and cost-effective (153USversus187US versus 187US per An. gambiae caught) because it allowed more spatially extensive and temporally intensive sampling (4284 versus 335 trap nights distributed over 615 versus 240 locations with a mean number of samples per year of 143 versus 141). Despite the very low vectors densities (Annual estimate of about 170 An gambiae s.l bites per person per year), CB-ITT was the only entomological predictor of parasite infection risk (Odds Ratio [95% CI] = 4.43[3.027,7. 454] per An. gambiae or Anopheles funestus caught per night, P =0.0373). Discussion and conclusion CB trapping approaches could be improved with more sensitive traps, but already offer a practical, safe and affordable system for routine programmatic mosquito surveillance and clusters could be distributed across entire countries by adapting the sample submission and quality assurance procedures accordingly
    corecore