86 research outputs found

    Inter- and intra-observer agreement of BI-RADS-based subjective visual estimation of amount of fibroglandular breast tissue with magnetic resonance imaging: comparison to automated quantitative assessment.

    Get PDF
    PURPOSE: To evaluate the inter-/intra-observer agreement of BI-RADS-based subjective visual estimation of the amount of fibroglandular tissue (FGT) with magnetic resonance imaging (MRI), and to investigate whether FGT assessment benefits from an automated, observer-independent, quantitative MRI measurement by comparing both approaches. MATERIALS AND METHODS: Eighty women with no imaging abnormalities (BI-RADS 1 and 2) were included in this institutional review board (IRB)-approved prospective study. All women underwent un-enhanced breast MRI. Four radiologists independently assessed FGT with MRI by subjective visual estimation according to BI-RADS. Automated observer-independent quantitative measurement of FGT with MRI was performed using a previously described measurement system. Inter-/intra-observer agreements of qualitative and quantitative FGT measurements were assessed using Cohen's kappa (k). RESULTS: Inexperienced readers achieved moderate inter-/intra-observer agreement and experienced readers a substantial inter- and perfect intra-observer agreement for subjective visual estimation of FGT. Practice and experience reduced observer-dependency. Automated observer-independent quantitative measurement of FGT was successfully performed and revealed only fair to moderate agreement (k = 0.209-0.497) with subjective visual estimations of FGT. CONCLUSION: Subjective visual estimation of FGT with MRI shows moderate intra-/inter-observer agreement, which can be improved by practice and experience. Automated observer-independent quantitative measurements of FGT are necessary to allow a standardized risk evaluation. KEY POINTS: • Subjective FGT estimation with MRI shows moderate intra-/inter-observer agreement in inexperienced readers. • Inter-observer agreement can be improved by practice and experience. • Automated observer-independent quantitative measurements can provide reliable and standardized assessment of FGT with MRI

    Computer-aided detection in breast MRI: a systematic review and meta-analysis

    Get PDF
    To evaluate the additional value of computer-aided detection (CAD) in breast MRI by assessing radiologists' accuracy in discriminating benign from malignant breast lesions. A literature search was performed with inclusion of relevant studies using a commercially available CAD system with automatic colour mapping. Two independent researchers assessed the quality of the studies. The accuracy of the radiologists' performance with and without CAD was presented as pooled sensitivity and specificity. Of 587 articles, 10 met the inclusion criteria, all of good methodological quality. Experienced radiologists reached comparable pooled sensitivity and specificity before and after using CAD (sensitivity: without CAD: 89%; 95% CI: 78-94%, with CAD: 89%; 95%CI: 81-94%) (specificity: without CAD: 86%; 95% CI: 79-91%, with CAD: 82%; 95% CI: 76-87%). For residents the pooled sensitivity increased from 72% (95% CI: 62-81%) without CAD to 89% (95% CI: 80-94%) with CAD, however, not significantly. Concerning specificity, the results were similar (without CAD: 79%; 95% CI: 69-86%, with CAD: 78%; 95% CI: 69-84%). CAD in breast MRI has little influence on the sensitivity and specificity of experienced radiologists and therefore their interpretation remains essential. However, residents or inexperienced radiologists seem to benefit from CAD concerning breast MRI evaluation

    Quantitative breast MRI: 2D histogram analysis of diffusion tensor parameters in normal tissue

    Full text link
    OBJECT: Diffusion tensor imaging (DTI) of the breast may provide a powerful new approach for the detection of intraductal processes. The aim of this investigation was to characterize the relation between diffusion tensor parameters [fractional anisotropy (FA), mean diffusivity (MD)] in normal breast tissue to obtain information on the microenvironment of the diffusing water molecules and to provide a systematic approach for DTI analysis. MATERIALS AND METHODS: Seven female, healthy volunteers underwent prospective double-spin-echo prepared echo-planar diffusion-weighted sequence (TR/TE 8,250 ms/74 ms, b values 0 and 500 s/mm (2), six encoding directions, 12 averages, 35 slices) in 4 consecutive weeks (3.0 T). Quantitative maps of diffusion tensor parameters were computed offline with custom routines. The interdependence of MD and FA in different voxels was analysed by linear and exponential regression. RESULTS: All MD and FA maps were of excellent quality. A consistent pattern was observed in that lower fractional anisotropy values were more likely associated with higher mean diffusivity values. The dependence exhibited an exponential behavior with a correlation coefficient R = 0.60 (R linear = 0.57). CONCLUSION: The likelihood with which FA and MD values are observed in a voxel within normal breast tissue is characterized by a specific pattern, which can be described by an exponential model. Moreover, we could show that the proposed technique does not depend on the menstrual cycle

    Consensus guidelines for the use and interpretation of angiogenesis assays

    Get PDF
    The formation of new blood vessels, or angiogenesis, is a complex process that plays important roles in growth and development, tissue and organ regeneration, as well as numerous pathological conditions. Angiogenesis undergoes multiple discrete steps that can be individually evaluated and quantified by a large number of bioassays. These independent assessments hold advantages but also have limitations. This article describes in vivo, ex vivo, and in vitro bioassays that are available for the evaluation of angiogenesis and highlights critical aspects that are relevant for their execution and proper interpretation. As such, this collaborative work is the first edition of consensus guidelines on angiogenesis bioassays to serve for current and future reference

    The utility of fast evolving molecular markers for studying speciation in the Antarctic benthos

    Get PDF
    The Southern Ocean is surprisingly rich in species that coexist in one of the most extreme environments on Earth yet the processes leading to speciation in this ecosystem are not well understood. To remedy this, tools that measure the genetic connectedness within a species are needed. Although useful for phylogenetic purposes, the readily available mitochondrial markers (e.g. 16S, COI) suffer from numerous shortcomings for population genetics. Therefore, molecular markers are needed that are sufficiently variable, unlinked, biparentally inherited, and distributed over the whole genome. We argue that microsatellites are suitable markers that have not been widely used in exploratory studies due to their difficult initial set-up. Working with the Ceratoserolis trilobitoides species complex (Isopoda), we demonstrate that using a novel protocol many microsatellites can be identified quickly. An increased availability of these highly sensitive markers will be useful for studies addressing the origin of species in the Southern Ocean and their response to future climate change
    corecore