1,916 research outputs found

    Assessment of catheter-manometer systems used for invasive blood pressure measurement

    Get PDF
    Direct measurement of blood pressure using a fluid-filled catheter and an electromechanical transducer is widely accepted in clinical practice. However, errors associated with the measurement are often not appreciated and these catheter-manometer systems are frequently unable to accurately reproduce applied pressures. To assess the accuracy of catheter-manometer systems used for invasive arterial blood pressure measurements, in vitro and in vivo evaluations were performed. The frequency response (described in terms of damped natural frequency and damping factor) for a variety of cannulae, pressure tubing and stopcocks (and combinations thereof) and their dependence on various parameters (catheter length, lumen diameter, fluid temperature and catheter material) were measured using an hydraulic pressure generator. The design and construction details of the pressure generator are presented. It was found that the damped natural frequency of the catheter-manometer system is directly proportional to lumen diameter of the pressure tubing/catheter. Furthermore, damping factor is inversely related to the damped natural frequency and stiffer catheter material (for identical radius ratios) results in higher damped natural frequency. Catheter length is inversely related to damped natural frequency and the resonant frequency decreases for an increase in fluid operating temperature. It was established that all catheter-manometer systems tested were under-damped (0.15 < β < 0.37) and that the damped natural frequency ranged from 10.5 Hz for 1500 mm to 27.0 Hz for pressure tubing of 300 mm in length. Furthermore, catheter-manometer systems which had pressure tubing in excess of 300 mm in length did not comply with the bandwidth requirements for accurate dynamic blood pressure measurement. For the in vivo assessment of the catheter-manometer system, the blood pressure waveform was analysed in the time and frequency domains. It was established that in 60 percent of the cases, the systolic pressure peak was higher when measured by a narrow bandwidth catheter-manometer system compared to that measured by a wide bandwidth system. Furthermore, values of dp/dt maximum were lower for wide bandwidth catheter-manometer systems than those measured by narrow bandwidth systems for heart rates above 90 beats per minute. In the frequency domain analysis, artifact was sometimes found to occur at frequencies higher than the bandwidth of the catheter-manometer system. This high frequency artifact was found to distort the blood pressure waveform and resulted in false high dp/dt and peak systolic pressures

    Sintering of BaCe(sub 0.85)Y(sub 0.15)O(sub 3-delta) with/without SrTiO3 Dopant

    Get PDF
    The perovskite composition, BaCe(sub 0.85)Y(sub 0.15)O(sub 3-delta), displays excellent protonic conduction at high temperatures making it a desirable candidate for hydrogen separation membranes. This paper reports on the sintering behavior of BaCe(sub 0.85)Y(sub 0.15)O(sub 3-delta) powders doped with SrTiO3. Two methods were used to synthesize BaCe(sub 0.85)Y(sub 0.15)O(sub 3-delta) powders: (1) solid state reaction and (2) wet chemical co-precipitation. Co-precipitated powder crystallized into the perovskite phase at 1000 C for 4 hrs. Complete reaction and crystallization of the perovskite phase by solid state was achieved by calcining at 1200 C for 24 hrs. Solid state synthesis produced a coarser powder with an average particle size of 1.3 microns and surface area of 0.74 sq m/g. Co-precipitation produced a finer powder with a average particle size of 65 nm and surface area of 14.9 sq m/g. Powders were doped with 1, 2, 5, and 10 mole % SrTiO3. Samples were sintered at 1450 C, 1550 C and 1650 C. SrTiO3 enhances sintering, optimal dopant level is different for powders synthesized by solid state and co-precipitation. Both powders exhibit similar grain growth behavior. Dopant levels of 5 and 10 mole % SrTiO3 significantly enhances the grain size

    Electronic structure of warm dense copper studied by ultrafast x-ray absorption spectroscopy

    Get PDF
    We use time-resolved x-ray absorption spectroscopy to investigate the unoccupied electronic density of states of warm dense copper that is produced isochorically through the absorption of an ultrafast optical pulse. The temperature of the superheated electron-hole plasma, which ranges from 4000 to 10 000 K, was determined by comparing the measured x-ray absorption spectrum with a simulation. The electronic structure of warm dense copper is adequately described with the high temperature electronic density of state calculated by the density functional theory. The dynamics of the electron temperature is consistent with a two-temperature model, while a temperature-dependent electron-phonon coupling parameter is necessary

    A grazing incidence x-ray streak camera for ultrafast, single-shot measurements

    Get PDF
    An ultrafast x-ray streak camera has been realized using a grazing incidence reflection photocathode. X-rays are incident on a gold photocathode at a grazing angle of 20° and photoemitted electrons are focused by a large aperture magnetic solenoid lens. The streak camera has high quantum efficiency, 600 fs temporal resolution, and 6 mm imaging length in the spectral direction. Its single shot capability eliminates temporal smearing due to sweep jitter, and allows recording of the ultrafast dynamics of samples that undergo nonreversible changes

    Evaluation of Nanomaterial Approaches to Damping in Epoxy Resin and Carbon Fiber/Epoxy Composite Structures by Dynamic Mechanical Analysis

    Get PDF
    Vibration mitigation in composite structures has been demonstrated through widely varying methods which include both active and passive damping. Recently, nanomaterials have been investigated as a viable approach to composite vibration damping due to the large surface available to generate energy dissipation through friction. This work evaluates the influence of dispersed nanoparticles on the damping ratio of an epoxy matrix. Limited benefit was observed through dispersion methods, however nanoparticle application as a coating resulting in up to a three-fold increase in damping

    The carbon budget of terrestrial ecosystems at country-scale – a European case study

    Get PDF
    We summed estimates of the carbon balance of forests, grasslands, arable lands and peatlands to obtain country-specific estimates of the terrestrial carbon balance during the 1990s. Forests and grasslands were a net sink for carbon, whereas croplands were carbon sources in all European countries. Hence, countries dominated by arable lands tended to be losing carbon from their terrestrial ecosystems, whereas forest-dominated countries tended to be sequestering carbon. In some countries, draining and extraction of peatlands caused substantial reductions in the net carbon balance. Net terrestrial carbon balances were typically an order of magnitude smaller than the fossil fuel-related carbon emissions. Exceptions to this overall picture were countries where population density and industrialization are small. It is, however, of utmost importance to acknowledge that the typically small net carbon balance represents the small difference between two large but opposing fluxes: uptake by forests and grasslands and losses from arable lands and peatlands. This suggests that relatively small changes in either or both of these large component fluxes could induce large effects on the net total, indicating that mitigation schemes should not be discarded a priori. In the absence of carbon-oriented land management, the current net carbon uptake is bound to decline soon. Protecting it will require actions at three levels; a) maintaining the current sink activity of forests, b) altered agricultural management practices to reduce the emissions from arable soils or turn into carbon sinks and c) protecting current large reservoirs (wetlands and old forests), since carbon is lost more rapidly than sequestered
    corecore