9 research outputs found

    Postintravitreal Injection Endophthalmitis: Incidence, Characteristics, Management, and Outcome

    No full text
    Purpose. Postintravitreal injection (IVI) endophthalmitis is a rare but devastating complication. Herein, we report the incidence ,and clinical and microbiological characteristics, as well as the visual outcome, in IVIs endophthalmitis in two medical centers. Methods. All patients undergoing intravitreal injections between 1/2018 and 12/2019 in two large medical centers were analyzed for post-IVI endophthalmitis. Results. Of the total of 51,356 IVIs performed, 23 cases of post-IVI endophthalmitis were diagnosed, yielding an overall incidence of 0.045%. The median interval from IVI to symptoms onset was 2 days (IQR: 1–5). Cultures were positive in 56% of the cases (100% Gram-positive bacteria and 76% coagulase-negative staphylococcus). Parameters associated with higher culture-positive rates included samples taken during vitrectomy, WBC on vitreous smear, the number of IVIs in the 12 months prior to presentation, and the time interval from last IVI to diagnostic sampling. At 6- and 12-month follow-up, the median change in VA (logMAR) was −1.10 (IQR: (−1.32)–(−0.40)) and −1.02 (IQR: (−1.10)–(−0.30)), respectively. Younger age and better BCVA at presentation were associated with better VA outcome, while positive culture result and systemic steroids treatment were each associated with the worse visual outcome. We found no difference in visual outcomes between PPV and TAI as a primary procedure. Conclusion. Post-IVI endophthalmitis is a rare complication, and most patients do not regain their initial VA. Certain parameters (clinical, microbiological, and therapeutic) may help anticipate the outcome and guide decision making regarding diagnosis and treatment

    Choroidal neovascular area and vessel density comparison between two swept-source optical coherence tomography angiography devices

    No full text
    PURPOSE: To compare choroidal neovascularization (CNV) area and vessel density (VD) measurements between two different swept-source optical coherence tomography angiography (SS-OCTA) devices. METHODS: En face optical coherence tomography angiography (OCTA) images of patients affected by neovascular age-related macular degeneration were collected prospectively from two devices: Zeiss PLEX Elite 9000 (Carl Zeiss Meditec, Dublin, CA) and Topcon DRI OCT Triton SS-OCTA (Topcon, Tokyo, Japan). Choroidal neovascularization area and VD of images were measured and analyzed with ImageJ software by two readers to evaluate the agreement between two devices, with respect to different image size (3 7 3 and 6 7 6 mm) and different image segmentation (automatic vs. manual), and a Topcon equivalent Zeiss segmentation as control (i.e., the equivalent anatomical slab given by Topcon device on the Zeiss device). RESULTS: A total of 30 eyes (30 patients) were analyzed. There was an excellent agreement between the two readers in CNV area measurements intraclass correlation coefficient >0.9 in all analyses. We found excellent agreement in CNV area measurements (manual and automatic segmentations) when comparing 3 7 3-mm or 6 7 6-mm images both for each single device and between the two devices (overall intraclass correlation coefficient > 0.9). Vessel density measurements between manual to automatic segmentation within the same device and same image size had a high intraclass correlation coefficient value, but there was a poor agreement in VD between different image sizes (3 7 3 mm vs. 6 7 6 mm) in the same device and also comparing the two devices (3 7 3 Topcon vs. 3 7 3 Zeiss; 6 7 6 Topcon vs. 6 7 6 Zeiss). There was a poor agreement between the Topcon equivalent Zeiss segmentation and all other segmentations. CONCLUSION: There was an excellent agreement in CNV area measurements for both swept-source optical coherence tomography angiography devices in automatic and manual segmentations. However, the Topcon equivalent Zeiss segmentation was not comparable with any of the preset segmentations of Topcon and Zeiss devices. There was a poor agreement in CNV VD between different image size and different devices. For these reasons, it seems that, for accurate longitudinal analysis of VD, it is better to use the same device for each individual, even if both devices can be used interchangeably for CNV area measurements using automatic or manual segmentations

    Progesterone Increases Bifidobacterium Relative Abundance during Late Pregnancy

    No full text
    Summary: Gestation is accompanied by alterations in the microbial repertoire; however, the mechanisms driving these changes are unknown. Here, we demonstrate a dramatic shift in the gut microbial composition of women and mice during late pregnancy, including an increase in the relative abundance of Bifidobacterium. Using in-vivo-transplanted pellets, we found that progesterone, the principal gestation hormone, affects the microbial community. The effect of progesterone on the richness of several bacteria species, including Bifidobacterium, was also demonstrated in vitro, indicating a direct effect. Altogether, our results delineate a model in which progesterone promotes Bifidobacterium growth during late pregnancy. : Nuriel-Ohayon et al. demonstrate a dramatic shift in the gut microbial composition of women and mice during late pregnancy, including an increase in the relative abundance of Bifidobacterium. Using in vitro and in vivo experiments, they show that supplementation of progesterone affects the microbial communities, including increasing the relative abundance of Bifidobacterium. Keywords: progesterone, Bifidobacterium, pregnancy, gut microbiota, 16S rRNA, microbiom
    corecore