28 research outputs found

    Significant effects in bread-making quality associated with the gene cluster Glu-D3/Gli-D1 from the bread wheat cultivar Prointa Guazú

    Get PDF
    Seed storage proteins (gliadins and glutenins) play a key role in the determination of dough and bread-making quality in bread wheat. This is due to the interaction between high and low molecular weight glutenins subunits and gliadins, via complex inter- and intramolecular bondings. In contrast to high molecular weight glutenins, low molecular weight glutenins and gliadins analysis is difficult due to the large number of expressed subunits and coding genes. For these reasons the role of individual proteins/subunits in the determination of wheat quality is less clear. In this work we studied the effect of gene clusters Glu-A3/Gli-A1 and Glu-D3/Gli-D1 in bread-making quality parameters using 20 F4-6 families from the cross Prointa Guazú × Prointa Oasis, both cultivars carrying identical high molecular weight glutenins subunits composition and presence of 1BL/1RS wheat-rye translocation, but differing in Glu-A3/Glu-D3 low molecular weight glutenins subunits and Gli-A1/Gli-D1 gliadins patterns. ANCOVA analysis showed a significant contribution of the Glu-D3/Gli-D1 gene cluster provided by Prointa Guazú to gluten strength explained by mixograph parameters MDS and PW, and Zeleny Test. Markers tagging Prointa Guazú Glu-D3/Gli-D1 alleles are available for strong gluten selection in breeding programs

    Search for 14.4 keV Solar Axions from M1 Transition of 57Fe with CUORE Crystals

    Get PDF
    We report the results of a search for axions from the 14.4 keV M1 transition from 57Fe in the core of the sun using the axio-electric effect in TeO2bolometers. The detectors are 5 × 5 × 5 cm3 crystals operated at about 10 mK in a facility used to test bolometers for the CUORE experiment at the Laboratori Nazionali del Gran Sasso in Italy. An analysis of 43.65 kg⋅d of data was made using a newly developed low energy trigger which was optimized to reduce the energy threshold of the detector. An upper limit of 0.58 c⋅kg−1⋅d−1 is established at 95% C.L., which translates into lower bounds fA ≥ 3.12 × 105 GeV 95% C.L. (DFSZ model) and fA ≥ 2.41 × 104 GeV 95% C.L. (KSVZ model) on the Peccei-Quinn symmetry-breaking scale, for a value of S = 0.5 of the flavor-singlet axial vector matrix element. These bounds can be expressed in terms of axion masses as mA ≤ 19.2 eV and mA ≤ 250 eV at 95% C.L. in the DFSZ and KSVZ models respectively. Bounds are given also for the interval 0.35 ≤ S ≤ 0.55

    Dark Matter Search with CUORE-0 and CUORE

    Get PDF
    The Cryogenic Underground Observatory for Rare Events (CUORE) is a ton-scale experiment made of TeO2 bolometers that will probe the neutrinoless double beta decay of 130Te. Excellent energy resolution, low threshold and low background make CUORE sensitive to nuclear recoils, allowing a search for dark matter interactions. With a total mass of 741 kg of TeO2, CUORE can search for an annual modulation of the counting rate at low energies. We present data obtained with CUORE-like detectors and the prospects for a dark matter search in CUORE-0, a 40-kg prototype, and CUORE

    CUORE and Beyond: Bolometric Techniques to Explore Inverted Neutrino Mass Hierarchy

    Get PDF
    The CUORE (Cryogenic Underground Observatory for Rare Events) experiment will search for neutrinoless double beta decay of 130Te. With 741 kg of TeO2 crystals and an excellent energy resolution of 5 keV (0.2%) at the region of interest, CUORE will be one of the most competitive neutrinoless double beta decay experiments on the horizon. With five years of live time, CUORE projected neutrinoless double beta decay half-life sensitivity is 1.6 × 1026 y at 1σ (9.5 × 1025 y at the 90% confidence level), which corresponds to an upper limit on the effective Majorana mass in the range 40–100 meV (50–130 meV). Further background rejection with auxiliary light detector can significantly improve the search sensitivity and competitiveness of bolometric detectors to fully explore the inverted neutrino mass hierarchy with 130Te and possibly other double beta decay candidate nuclei

    Histological and ultra-structural effects of rapid muscle expansion through intramuscular administration of carbon dioxide: an intra-operative study in an animal model

    No full text
    INTRODUCTION: Carbon dioxide (CO2) therapy refers to trans-cutaneous or subcutaneous administration of CO2 for therapeutic purposes, and recent studies have pointed out that it produces a vasodilation effect after it is locally injected, which helps amplify the reconstructive potentiality of an expanded-muscle flap. MATERIALS AND METHODS: Thirty male Wistar rats, weighting between 350 and 400 g, were randomly divided into three groups of 10. In the first group, single intra-operative rapid expansion was carried out under the right latissimus dorsi muscle. In the second group, for five days prior to surgery, a pre-treatment with intramuscular injections of CO2 was performed. The third group served as controls. For each group, the latissimus dorsi muscle was fixed as soon possible after mice died, and ultrathin sections of it examined with transmission electron microscope. RESULTS: In the treated group, the majority of expanded muscles showed a normal striation pattern, whereas a few fibers showed mild disorganization of the myo-filaments in the sarcomeres, which appeared overstretched (average 2.37 μm). CONCLUSIONS: This evidence could demonstrate a greater capacity of muscle recovery after treatment by CO2 expansion

    Development of large-volume 130^{130}TeO2_2 bolometers for the CROSS 2β2\beta decay search experiment

    No full text
    International audienceWe report on the development of thermal detectors based on large-size tellurium dioxide crystals (45x45x45 mm), containing tellurium enriched in 130^{130}Te to ~91%, for the CROSS double-beta decay experiment. A powder used for the crystals growth was additionally purified by the directional solidification method, resulting in the reduction of the concentration of impurities by a factor 10, to a few ppm of the total concentration of residual elements (the main impurity is Fe). The purest part of the ingot (the first ~200 mm, ~80% of the total length of the cylindrical part of the ingot) was determined by scanning segregation profiles of impurities (both on the surface and in center of the ingot) and used for the 130^{130}TeO2_2 powder production with no evidence of re-contamination. The crystal growth was verified with precursors produced from powder with natural Te isotopic composition, and two small-size (20x20x10 mm) samples were tested at a sea-level laboratory showing high bolometric and spectrometric performance together with acceptable 210^{210}Po content (below 10 mBq/kg). This growth method was then applied for the production of six large cubic 130^{130}TeO2_2 crystals for the CROSS experiment and 4 of them were taken randomly to be characterized at the Canfranc underground laboratory, in the CROSS-dedicated low-background cryogenic facility. Two 130^{130}TeO2_2 samples were coated with a thin metal film in form of Al layer (on 4 sides) or AlPd grid (on a single side) to investigate the possibility to tag surface events by pulse-shape discrimination. Similarly to the small natural precursors, large-volume 130^{130}TeO2_2 bolometers show high performance and even better internal purity (210^{210}Po activity ~ 1 mBq/kg, while activities of 228^{228}Th and 226^{226}Ra are below 0.01 mBq/kg), satisfying requirements for the CROSS and, potentially, next-generation experiments

    CUORE crystal validation runs: Results on radioactive contamination and extrapolation to CUORE background

    No full text
    The CUORE Crystal Validation Runs (CCVRs) have been carried out since the end of 2008 at the Gran Sasso National Laboratories, in order to test the performance and the radiopurity of the TeO 2 crystals produced at SICCAS (Shanghai Institute of Ceramics, Chinese Academy of Sciences) for the CUORE experiment. In this work the results of the first 5 validation runs are presented. Results have been obtained for bulk contaminations and surface contaminations from several nuclides. An extrapolation to the CUORE background has been performed. © 2012 Elsevier B.V. All rights reserved
    corecore