197 research outputs found

    Why I tense up when you watch me: inferior parietal cortex mediates an audience’s influence on motor performance

    Get PDF
    The presence of an evaluative audience can alter skilled motor performance through changes in force output. To investigate how this is mediated within the brain, we emulated real-time social monitoring of participants’ performance of a fine grip task during functional magnetic resonance neuroimaging. We observed an increase in force output during social evaluation that was accompanied by focal reductions in activity within bilateral inferior parietal cortex. Moreover, deactivation of the left inferior parietal cortex predicted both inter- and intra-individual differences in socially-induced change in grip force. Social evaluation also enhanced activation within the posterior superior temporal sulcus, which conveys visual information about others’ actions to the inferior parietal cortex. Interestingly, functional connectivity between these two regions was attenuated by social evaluation. Our data suggest that social evaluation can vary force output through the altered engagement of inferior parietal cortex; a region implicated in sensorimotor integration necessary for object manipulation, and a component of the action-observation network which integrates and facilitates performance of observed actions. Social-evaluative situations may induce high-level representational incoherence between one’s own intentioned action and the perceived intention of others which, by uncoupling the dynamics of sensorimotor facilitation, could ultimately perturbe motor output

    Polyethylene thickness is a risk factor for wear necessitating insert exchange

    Get PDF
    PURPOSE: The aim of this observational study was to investigate the optimal minimal polyethylene (PE) thickness in total knee arthroplasty (TKA) and identify other risk factors associated with revision of the insert due to wear. METHODS: A total of 84 TKA were followed for 11-16 years. All patients received the same prosthesis design (Interax; Howmedica/ Stryker) with halfbearings: separate PE-inserts medially and laterally. Statistical analysis comprised Cox-regression to correct for confounding. RESULTS: Eight knees (9.5%) had been revised due to thinning inserts and an additional patient is scheduled for revision. PE thickness, diagnosis, BMI and weight are risk factors for insert exchange. For each millimetre decrease in PE thickness, the risk of insert exchange increases 3.0 times, which remains after correction for age, gender, weight, diagnosis and femoral-tibial angle. Insert exchange was 4.73 times more likely in OA-patients compared to RA-patients. For every unit increase in BMI and weight the risk for insert exchange increases 1.40 times and 1.14 times, respectively. CONCLUSIONS: In conclusion we therefore advise against the use of thin PE inserts in modular TKA and recommend PE inserts with a minimal 8-mm thickness.Optimising joint reconstruction management in arthritis and bone tumour patient

    Maternal Near Miss and Mortality in a Rural Referral Hospital in Northern Tanzania: A Cross-Sectional Study.

    Get PDF
    Maternal morbidity and mortality in sub-Saharan Africa remains high despite global efforts to reduce it. In order to lower maternal morbidity and mortality in the immediate term, reduction of delay in the provision of quality obstetric care is of prime importance. The aim of this study is to assess the occurrence of severe maternal morbidity and mortality in a rural referral hospital in Tanzania as proposed by the WHO near miss approach and to assess implementation levels of key evidence-based interventions in women experiencing severe maternal morbidity and mortality. A prospective cross-sectional study was performed from November 2009 until November 2011 in a rural referral hospital in Tanzania. All maternal near misses and maternal deaths were included. As not all WHO near miss criteria were applicable, a modification was used to identify cases. Data were collected from medical records using a structured data abstraction form. Descriptive frequencies were calculated for demographic and clinical variables, outcome indicators, underlying causes, and process indicators. In the two-year period there were 216 maternal near misses and 32 maternal deaths. The hospital-based maternal mortality ratio was 350 maternal deaths per 100,000 live births (95% CI 243-488). The maternal near miss incidence ratio was 23.6 per 1,000 live births, with an overall case fatality rate of 12.9%. Oxytocin for prevention of postpartum haemorrhage was used in 96 of 201 women and oxytocin for treatment of postpartum haemorrhage was used in 38 of 66 women. Furthermore, eclampsia was treated with magnesium sulphate in 87% of all cases. Seventy-four women underwent caesarean section, of which 25 women did not receive prophylactic antibiotics. Twenty-eight of 30 women who were admitted with sepsis received parenteral antibiotics. The majority of the cases with uterine rupture (62%) occurred in the hospital. Maternal morbidity and mortality remain challenging problems in a rural referral hospital in Tanzania. Key evidence-based interventions are not implemented in women with severe maternal morbidity and mortality. Progress can be made through up scaling the use of evidence-based interventions, such as the use of oxytocin for prevention and treatment of postpartum haemorrhage

    Second-look PET-CT following an initial incomplete PET-CT response to (chemo)radiotherapy for head and neck squamous cell carcinoma

    Get PDF
    OBJECTIVES: The limited positive predictive value of an incomplete response on PET-CT following (chemo)radiotherapy for head and neck squamous cell carcinoma (HNSCC) means that the optimal management strategy remains uncertain. The aim of the study is to assess the utility of a 'second-look' interval PET-CT. METHODS: Patients with HNSCC who were treated with (chemo)radiotherapy between 2008 and 2017 and underwent (i) baseline and (ii) response assessment PET-CT and (iii) second-look PET-CT following incomplete (positive or equivocal scan) response were included. Endpoints were conversion rate to complete response (CR) and test characteristics of the second-look PET-CT. RESULTS: Five hundred sixty-two patients with HNSCC underwent response assessment PET-CT at a median of 17 weeks post-radiotherapy. Following an incomplete response on PET-CT, 40 patients underwent a second-look PET-CT at a median of 13 weeks (range 6-25) from the first response PET-CT. Thirty-four out of 40 (85%) patients had oropharyngeal carcinoma. Twenty-four out of 40 (60%) second-look PET-CT scans converted to a complete locoregional response. The primary tumour conversion rate was 15/27 (56%) and the lymph node conversion rate was 14/19 (74%). The sensitivity, specificity, positive predictive value and negative predictive value (NPV) of the second-look PET-CT were 75%, 75%, 25% and 96% for the primary tumour and 100%, 92%, 40% and 100% for lymph nodes. There were no cases of progression following conversion to CR in the primary site or lymph nodes. CONCLUSIONS: The majority of patients who undergo a second-look PET-CT convert to a CR. The NPV of a second-look PET-CT is high, suggesting the potential to avoid surgical intervention. KEY POINTS: • PET-CT is a useful tool for response assessment following (chemo)radiotherapy for head and neck squamous cell carcinoma. • An incomplete response on PET-CT has a limited positive predictive value and optimal management is uncertain. • These data show that with a 'second-look' interval PET-CT, the majority of patients convert to a complete metabolic response. When there is doubt about clinical and radiological response, a 'second-look' PET-CT can be used to spare patients unnecessary surgical intervention

    A retrospective analysis of bilateral fractures over sixteen years: localisation and variation in treatment of second hip fractures

    Get PDF
    The aim of this study was the evaluation of contralateral hip fractures after a previous hip fracture. For this retrospective analysis patients were selected from the database of the LUMC, a teaching hospital in the south-west of the Netherlands. We analyzed all patients with a second fracture of a hip between 1992 and 2007. The exclusion criteria were high impact trauma and patients with diseases or medication known to have a negative effect on bone metabolism. A total of 1,604 hip fractures were identified. The possible predictive factors for the second fracture and descriptive statistics related to surgery (Hb and HT before and after the operation, total amount of intra- and postoperative blood loss, type of osteosynthesis, complications, time of death after the last fracture, time between arrival in the hospital and operation and hospital stay for both fractures) were recorded. A total of 32 second hip fractures were identified (2%) at a mean of 27.5 (SD 28.9) months after the initial hip fracture. The mean age at the first fracture was 77.2 years (SD 11.7), and 27 of 32 patients were female. Of these 32 patients (64 bilateral hip fractures), 32 fractures were intracapsular (1 femoral neck, 31 subcapital) and 32 were extracapsular fractures (6 subtrochanteric, 26 transtrochanteric). Although 24 of the 32 patients had identical first and second hip fractures, only eight out of 32 hips were treated with the same implants. There was a significant difference in Singh index between both hips at the time of the first fracture. There was also a significant difference in Singh index between the hip which was not fractured compared with its subsequent index when it was broken. All other studied patient and fracture characteristics were not significantly different. In this population the percentage of second hip fractures was relatively low compared to other studies. The choice of implants in this study shows that implants were chosen randomly. Because there is a significant difference in the Singh index during first and second hip fracture, osteoporosis medication might help reduce the incidence of second hip fractures

    Automatic radiographic quantification of hand osteoarthritis; accuracy and sensitivity to change in joint space width in a phantom and cadaver study

    Get PDF
    This is the final version of the article. Available from Springer Verlag via the DOI in this record.OBJECTIVE: To validate a newly developed quantification method that automatically detects and quantifies the joint space width (JSW) in hand radiographs. Repeatability, accuracy and sensitivity to changes in JSW were determined. The influence of joint location and joint shape on the measurements was tested. METHODS: A mechanical micrometer set-up was developed to define and adjust the true JSW in an acrylic phantom joint and in human cadaver-derived phalangeal joints. Radiographic measurements of the JSW were compared to the true JSW. Repeatability, systematic error (accuracy) and sensitivity (defined as the smallest detectable difference (SDD)) were determined. The influence of joint position on the JSW measurement was assessed by varying the location of the acrylic phantom on the X-ray detector with respect to the X-ray beam and the influence of joint shape was determined by using morphologically different human cadaver joints. RESULTS: The mean systematic error was 0.052 mm in the phantom joint and 0.210 mm in the cadaver experiment. In the phantom experiments, the repeatability was high (SDD = 0.028 mm), but differed slightly between joint locations (p = 0.046), and a change in JSW of 0.037 mm could be detected. Dependent of the joint shape in the cadaver hand, a change in JSW between 0.018 and 0.047 mm could be detected. CONCLUSIONS: The automatic quantification method is sensitive to small changes in JSW. Considering the published data of JSW decline in the normal and osteoarthritic population, the first signs of OA progression with this method can be detected within 1 or 2 years.This work was funded by the Dutch Arthritis Association (Reumafonds). The study sponsor had no involvement in study design, data collection, data analysis, or interpretation of the results

    The African Cichlid Fish Astatotilapia burtoni Uses Acoustic Communication for Reproduction: Sound Production, Hearing, and Behavioral Significance

    Get PDF
    Sexual reproduction in all animals depends on effective communication between signalers and receivers. Many fish species, especially the African cichlids, are well known for their bright coloration and the importance of visual signaling during courtship and mate choice, but little is known about what role acoustic communication plays during mating and how it contributes to sexual selection in this phenotypically diverse group of vertebrates. Here we examined acoustic communication during reproduction in the social cichlid fish, Astatotilapia burtoni. We characterized the sounds and associated behaviors produced by dominant males during courtship, tested for differences in hearing ability associated with female reproductive state and male social status, and then tested the hypothesis that female mate preference is influenced by male sound production. We show that dominant males produce intentional courtship sounds in close proximity to females, and that sounds are spectrally similar to their hearing abilities. Females were 2–5-fold more sensitive to low frequency sounds in the spectral range of male courtship sounds when they were sexually-receptive compared to during the mouthbrooding parental phase. Hearing thresholds were also negatively correlated with circulating sex-steroid levels in females but positively correlated in males, suggesting a potential role for steroids in reproductive-state auditory plasticity. Behavioral experiments showed that receptive females preferred to affiliate with males that were associated with playback of courtship sounds compared to noise controls, indicating that acoustic information is likely important for female mate choice. These data show for the first time in a Tanganyikan cichlid that acoustic communication is important during reproduction as part of a multimodal signaling repertoire, and that perception of auditory information changes depending on the animal's internal physiological state. Our results highlight the importance of examining non-visual sensory modalities as potential substrates for sexual selection contributing to the incredible phenotypic diversity of African cichlid fishes

    Politeness and compassion differentially predict adherence to fairness norms and interventions to norm violations in economic games

    Get PDF
    Adherence to norms and interventions to norm violations are two important forms of social behaviour modelled in economic games. While both appear to serve a prosocial function, they may represent separate mechanisms corresponding with distinct emotional and psychological antecedents, and thus may be predicted by different personality traits. In this study, we compared adherence to fairness norms in the dictator game with responses to violations of the same norms in third-party punishment and recompensation games with respect to prosocial traits from the Big Five and HEXACO models of personality. The results revealed a pattern of differential relations between prosocial traits and game behaviours. While norm adherence in the dictator game was driven by traits reflecting good manners and non-aggression (i.e., the politeness aspect of Big Five agreeableness and HEXACO honesty-humility), third-party recompensation of victims—and to a lesser extent, punishment of offenders—was uniquely driven by traits reflecting emotional concern for others (the compassion aspect of Big Five agreeableness). These findings demonstrate the discriminant validity between similar prosocial constructs and highlight the different prosocial motivations underlying economic game behaviours

    A computed tomography based study on rotational alignment accuracy of the femoral component in total knee arthroplasty using computer-assisted orthopaedic surgery

    Get PDF
    Rotation of the femoral component in total knee arthroplasty (TKA) is of high importance in respect of the balancing of the knee and the patellofemoral joint. Though it is shown that computer assisted surgery (CAOS) improves the anteroposterior (AP) alignment in TKA, it is still unknown whether navigation helps in finding the accurate rotation or even improving rotation. Therefore the aim of our study was to evaluate the postoperative femoral component rotation on computed tomography (CT) with the intraoperative data of the navigation system. In 20 navigated TKAs the difference between the intraoperative stored rotation data of the femoral component and the postoperative rotation on CT was measured using the condylar twist angle (CTA). This is the angle between the epicondylar axis and the posterior condylar axis. Statistical analysis consisted of the intraclass correlation coefficient (ICC) and Bland-Altman plot. The mean intraoperative rotation CTA based on CAOS was 3.5° (range 2.4–8.6°). The postoperative CT scan showed a mean CTA of 4.0° (1.7–7.2). The ICC between the two observers was 0.81, and within observers this was 0.84 and 0.82, respectively. However, the ICC of the CAOS CTA versus the postoperative CT CTA was only 0.38. Though CAOS is being used for optimising the position of a TKA, this study shows that the (virtual) individual rotational position of the femoral component using a CAOS system is significantly different from the position on a postoperative CT scan
    • …
    corecore