1,060 research outputs found

    Three dimensional thermal analysis of rocket thrust chambers

    Get PDF
    A numerical model for the three dimensional thermal analysis of rocket thrust chambers and nozzles has been developed. The input to the model consists of the composition of the fuel/oxidant mixture and flow rates, chamber pressure, coolant entrance temperature and pressure, dimensions of the engine, materials and the number of nodes in different parts of the engine. The model allows for temperature variation in three dimensions: axial, radial and circumferential directions and by implementing an iterative scheme, it provides nodal temperature distribution, rates of heat transfer, hot gas and coolant thermal and transport properties

    Project of a superfluid He3 detector for direct detection of non-baryonic dark matter : MACHe3

    Full text link
    MACHe3 (MAtrix of Cells of superfluid Helium 3) is a project of non-baryonic Dark Matter search using superfluid He3 as sensitive medium. Simulations on a high granularity matrix show very good rejection against background events. First results on a prototype cell are very encouraging. Neutron detection has been highlighted as well as cosmic muon detection. A phenomenological study has been done with the DarkSUSY code to investigate complementarity of MACHe3 with existing Dark Matter detectors.Comment: 5 pages, 5 figures, to appear in Proceedings of the 4th Marseille International Cosmology Conferenc

    Hip and Groin Pain in the Professional Athlete

    Get PDF
    AbstractHip and groin pain is a common condition in professional athletes and may result from an acute injury or from chronic, repetitive trauma. It is responsible for significant morbidity, which leads to time away from training and competition, and may result in a career-ending injury. The anatomic and biomechanical causes for hip and groin injuries are among the most complex and controversial in the musculoskeletal system. This makes clinical differentiation and subsequent management difficult because of the considerable overlap of symptoms and signs. This review article will evaluate several pathologic conditions of the hip and groin in athletes, divided into acute (secondary to single event) and chronic (secondary to altered biomechanical load or repetitive microtrauma) injuries, with an emphasis on imaging in the diagnosis of these injuries. Appropriate use of imaging along with clinical findings can allow accurate diagnosis and subsequent appropriate management of these patients to ultimately allow return to athletic activity

    Negative HER2/neu amplification using immunohistochemistry and chromogenic in situ hybridization techniques in skin melanoma cases

    Get PDF
    Background: This study was performed to evaluate the amplification of HER-2/neu in patients with melanoma. Materials and Methods: Amplification of HER-2/neu was evaluated in a group of patients with melanoma, referred to two referral centers in Tehran, using immunohistochemistry (IHC) and chromogenic in situ hybridization (CISH) techniques. Results: Forty patients with mean age 57.9±19.5 years were enrolled in this study. The most frequent type of melanoma was acral, while lower limbs were the most frequent sites. The amplification of HER2/ neu was negative in 97.5 of patients with IHC and in 100 of patients with CISH technique. Only one case (2.5) shows weak positive staining (+2) in IHC method. Fifty five percent of melanoma was ulcerative, and the most common stages of tumors were stages 4b and 3b. More than 47 of cases were in Clark level III, while the mean of Breslow thickness was 3.56±2.87 mm. The stage of the case that showed weakly positive staining (2+) in IHC was 4b. Conclusions: The amplification of HER2/neu biomarker was negative in patients with melanoma, using both CISH and IHC techniques

    Report of the GDR working group on the R-parity violation

    Full text link
    This report summarizes the work of the "R-parity violation group" of the French Research Network (GDR) in Supersymmetry, concerning the physics of supersymmetric models without conservation of R-parity at HERA, LEP, Tevatron and LHC and limits on R-parity violating couplings from various processes. The report includes a discussion of the recent searches at the HERA experiment, prospects for new experiments, a review of the existing limits, and also theoretically motivated alternatives to R-parity and a brief discussion on the implications of R-parity violation on the neutrino masses.Comment: 60 pages, LaTeX, 22 figures, 2 table

    Conformational changes of calmodulin upon Ca2+ binding studied with a microfluidic mixer

    Get PDF
    A microfluidic mixer is applied to study the kinetics of calmodulin conformational changes upon Ca2+ binding. The device facilitates rapid, uniform mixing by decoupling hydrodynamic focusing from diffusive mixing and accesses time scales of tens of microseconds. The mixer is used in conjunction with multiphoton microscopy to examine the fast Ca2+-induced transitions of acrylodan-labeled calmodulin. We find that the kinetic rates of the conformational changes in two homologous globular domains differ by more than an order of magnitude. The characteristic time constants are ≈490 ÎŒs for the transitions in the C-terminal domain and ≈20 ms for those in the N-terminal domain of the protein. We discuss possible mechanisms for the two distinct events and the biological role of the stable intermediate, half-saturated calmodulin

    Relating a calcium indicator signal to the unperturbed calcium concentration time-course

    Get PDF
    BACKGROUND: Optical indicators of cytosolic calcium levels have become important experimental tools in systems and cellular neuroscience. Indicators are known to interfere with intracellular calcium levels by acting as additional buffers, and this may strongly alter the time-course of various dynamical variables to be measured. RESULTS: By investigating the underlying reaction kinetics, we show that in some ranges of kinetic parameters one can explicitly link the time dependent indicator signal to the time-course of the calcium influx, and thus, to the unperturbed calcium level had there been no indicator in the cell

    Detection of splenic microabscesses with ultrasound as a marker for extrapulmonary tuberculosis in patients with HIV: A systematic review

    Get PDF
    Background. In 2015, 1.2 million new cases of tuberculosis (TB) were diagnosed in patients with HIV. Diagnostic limitations and resource shortages in endemic areas can delay diagnosis and treatment, particularly with extrapulmonary TB (EPTB). Research suggests that ultrasound can identify splenic microabscesses caused by EPTB, but data are limited on the frequency of this finding in patients with culture-proven EPTB.Objectives. To estimate the frequency of splenic EPTB microabscesses detected with ultrasound in patients with HIV and TB co-infection.Methods. Studies published in six major databases as of November 2017 were systematically reviewed based on the PRISMA guidelines. Cohen’s kappa test was used to determine inter-rater agreement. Articles included for data abstraction passed the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) evaluation. Freeman-Tukey transformation was used to calculate weighted proportions. Heterogeneity was evaluated by Forest plot and I2 calculation.Results. After abstract screening, article review and QUADAS-2 evaluation, five studies were selected for data extraction. A total of 774 patients in these studies were infected with HIV. Splenic lesions were seen with ultrasound in 21.0% of patients with HIV (95% confidence interval (CI) 10.6 - 33.8). TB diagnosed by culture, biopsy, smear, or molecular methods was found to be the cause of 88.3% (95% CI 72.3 - 97.9) of splenic microabscesses seen on ultrasound in patients with HIV.Conclusions. Ultrasound evaluation of the spleen in patients with HIV and symptoms suggestive of TB in endemic regions is a viable diagnostic adjunct. Ultrasound detection of splenic microabscesses in HIV patients is probably sufficient indication to initiate TB treatment prior to obtaining culture data. Strong conclusions cannot be drawn owing to the high heterogeneity of this small number of studies.

    First Detection of Polarization of the Submillimetre Diffuse Galactic Dust Emission by Archeops

    Get PDF
    We present the first determination of the Galactic polarized emission at 353 GHz by Archeops. The data were taken during the Arctic night of February 7, 2002 after the balloon--borne instrument was launched by CNES from the Swedish Esrange base near Kiruna. In addition to the 143 GHz and 217 GHz frequency bands dedicated to CMB studies, Archeops had one 545 GHz and six 353 GHz bolometers mounted in three polarization sensitive pairs that were used for Galactic foreground studies. We present maps of the I, Q, U Stokes parameters over 17% of the sky and with a 13 arcmin resolution at 353 GHz (850 microns). They show a significant Galactic large scale polarized emission coherent on the longitude ranges [100, 120] and [180, 200] deg. with a degree of polarization at the level of 4-5%, in agreement with expectations from starlight polarization measurements. Some regions in the Galactic plane (Gem OB1, Cassiopeia) show an even stronger degree of polarization in the range 10-20%. Those findings provide strong evidence for a powerful grain alignment mechanism throughout the interstellar medium and a coherent magnetic field coplanar to the Galactic plane. This magnetic field pervades even some dense clouds. Extrapolated to high Galactic latitude, these results indicate that interstellar dust polarized emission is the major foreground for PLANCK-HFI CMB polarization measurement.Comment: Submitted to Astron. & Astrophys., 14 pages, 12 Fig., 2 Table

    Barriers to Diffusion in Dendrites and Estimation of Calcium Spread Following Synaptic Inputs

    Get PDF
    The motion of ions, molecules or proteins in dendrites is restricted by cytoplasmic obstacles such as organelles, microtubules and actin network. To account for molecular crowding, we study the effect of diffusion barriers on local calcium spread in a dendrite. We first present a model based on a dimension reduction approach to approximate a three dimensional diffusion in a cylindrical dendrite by a one-dimensional effective diffusion process. By comparing uncaging experiments of an inert dye in a spiny dendrite and in a thin glass tube, we quantify the change in diffusion constants due to molecular crowding as Dcyto/Dwater = 1/20. We validate our approach by reconstructing the uncaging experiments using Brownian simulations in a realistic 3D model dendrite. Finally, we construct a reduced reaction-diffusion equation to model calcium spread in a dendrite under the presence of additional buffers, pumps and synaptic input. We find that for moderate crowding, calcium dynamics is mainly regulated by the buffer concentration, but not by the cytoplasmic crowding, dendritic spines or synaptic inputs. Following high frequency stimulations, we predict that calcium spread in dendrites is limited to small microdomains of the order of a few microns (<5 ÎŒm)
    • 

    corecore