10 research outputs found

    State of the art in bile analysis in forensic toxicology

    Get PDF
    AbstractIn forensic toxicology, alternative matrices to blood are useful in case of limited, unavailable or unusable blood sample, suspected postmortem redistribution or long drug intake-to-sampling interval. The present article provides an update on the state of knowledge for the use of bile in forensic toxicology, through a review of the Medline literature from 1970 to May 2015. Bile physiology and technical aspects of analysis (sampling, storage, sample preparation and analytical methods) are reported, to highlight specificities and consequences from an analytical and interpretative point of view. A table summarizes cause of death and quantification in bile and blood of 133 compounds from more than 200 case reports, providing a useful tool for forensic physicians and toxicologists involved in interpreting bile analysis. Qualitative and quantitative interpretation is discussed. As bile/blood concentration ratios are high for numerous molecules or metabolites, bile is a matrix of choice for screening when blood concentrations are low or non-detectable: e.g., cases of weak exposure or long intake-to-death interval. Quantitative applications have been little investigated, but small molecules with low bile/blood concentration ratios seem to be good candidates for quantitative bile-based interpretation. Further experimental data on the mechanism and properties of biliary extraction of xenobiotics of forensic interest are required to improve quantitative interpretation

    Postmortem measurement of human chorionic gonadotropin in vitreous humor and bile.

    No full text
    Postmortem human chorionic gonadotrophin (HCG) blood assay can confirm postmortem diagnosis of pregnancy or document situations in which HCG levels are elevated. In some cases, however, blood sampling is not possible at autopsy. In this study, HCG was quantified by enzyme-linked fluorescent assay (ELFA) in the bile (n = 5), vitreous humor (n = 4), and postmortem blood (n = 4) of five pregnant women. There were no false negatives in the pregnant subjects (n = 5) or false positives in controls (n = 34), enabling this test to be recommended for routine use in forensic contexts in which the detection of elevated HCG levels could be of interest

    Development and validation of a method for quantification of human insulin and its synthetic analogues in plasma and post-mortem sera by LC-MS/HRMS.

    No full text
    Analysis of human insulin and its synthetic analogues is increasingly requested for clinical monitoring, for anti-doping purposes, but also for forensic cases. Indeed, insulin analogues may be abused for suicide or homicide - whence their forensic interest. Collection and storage conditions, as well as the phenomenon of degradation make post-mortem serum samples analytically challenging and consequently, the rate of exogenous insulin administration as cause of death is undoubtedly underestimated. However, with recent technological advances and the development of new extraction techniques particularly for anti-doping analyses, detection of insulins in post-mortem samples seems to be achievable. This study describes the first validated quantitative method for analysis human insulin and its six analogues (lispro, aspart, glulisine, glargine, detemir and degludec) in plasma and post-mortem sera. Various extraction processes, namely precipitation + solid phase extraction (SPE), filtration + SPE, precipitation + SPE + immunopurification, and filtration + immunopurification, were assessed to evaluate the lowest limit of detection for all target analogues. The selected sample preparation consists of filtration step followed by immunopurification extraction with an anti-body precoated ELISA plate for plasma. For post-mortem sera, the first step of precipitation was added to remove matrix interferences. The extracts were analyzed by ultra-high-performance liquid chromatography-high resolution mass spectrometry (LC-HRMS), interfaced by electrospray (ESI). The method was validated with respect linearity, precision, accuracy, recovery, matrix effect, dilution and carryover. The limit of quantification (LOQ) in plasma was 0.5 ng/mL for human insulin and rapid-acting insulins, 1.0 ng/mL for glargine, 2.5 ng/mL for degludec and 10 ng/mL for detemir. Two types of post-mortem sera were studied based on the post-mortem interval (PMI): inferior or superior to 48 h. The obtained LOQ were the same for each analogue, independent from the PMI: 1.0 ng/mL for human insulin and rapid-acting insulins, 1.0 ng/mL for glargine, 2.5 ng/mL for degludec and 10 ng/mL for detemir. At the LOQ level, for all insulins and all samples, accuracy was between 70 and 130% and precision inferior to 30%. The validated method was applied to five subjects participating in therapeutic monitoring of insulin and to seven post-mortem cases

    Study of a large scale powdered activated carbon pilot: Removals of a wide range of emerging and priority micropollutants from wastewater treatment plant effluents

    No full text
    International audienceThe efficacy of a fluidized powdered activated carbon (PAC) pilot (CarboPlus®) was studied in both nominal (total nitrification + post denitrification) and degraded (partial nitrification + no denitrification) configuration of the Seine Centre WWTP (Colombes, France). In addition to conventional wastewater parameters 54 pharmaceuticals and hormones (PhPHs) and 59 other emerging pollutants were monitored in influents and effluents of the pilot. Thus, the impacts of the WWTP configuration, the process operation and the physico-chemical properties of the studied compounds were assessed in this article.Among the 26 PhPHs quantified in nominal WWTP configuration influents, 8 have high dissolved concentrations (>100 ng/L), 11 have an intermediary concentration (10–100 ng/L) and 7 are quantified below 10 ng/L. Sulfamethoxazole is predominant (about 30% of the sum of the PhPHs). Overall, 6 PhPHs are poorly to moderately removed (80%), i.e. beta blockers, carbamazepine or trimethoprim, and 11 are well eliminated (60–80%), i.e. diclofenac, naproxen or sulfamethoxazole.In degraded WWTP configuration, higher levels of organic matter and higher concentrations of most pollutants are observed. Consequently, most PhPHs are substantially less removed in percentages but the removed flux is higher. Thus, the PAC dose required to achieve a given removal percentage is higher in degraded WWTP configuration. For the other micropollutants (34 quantified), artificial sweeteners and phthalates are found at particularly high concentrations in degraded WWTP configuration influents, up to μg/L range. Only pesticides, bisphenol A and parabens are largely eliminated (50–95%), while perfluorinated acids, PAHs, triclosan and sweeteners are not or weakly removed (<50%). The remaining compounds exhibit a very variable fate from campaign to campaign.The fresh PAC dose was identified as the most influencing operation parameter and is strongly correlated to performances. Charge and hydrophobicity of compounds have been recognized as crucial for the micropollutant adsorption on PAC, as well as the molecular weight. Finally, a PAC dose of 10 mg/L allows an average removal of 72–80% of the sum of the PhPHs in nominal WWTP configuration. The comparaison of the results with those from the scarce other studies tends to indicate that an extrapolation of them to different PAC processes and to other WWTPs could be possible and relevant, taking into account the differences of water quality from WWTP to WWTP

    State of the art in bile analysis in forensic toxicology

    No full text

    Vitreous humor analysis for the detection of xenobiotics in forensic toxicology: a review

    No full text
    corecore