54 research outputs found

    First Direct Observation of Nanometer size Hydride Precipitations on Superconducting Niobium

    Full text link
    Superconducting niobium serves as a key enabling material for superconducting radio frequency (SRF) technology as well as quantum computing devices. At room temperature, hydrogen commonly occupies tetragonal sites in the Nb lattice as metal (M)-gas (H) phase. When the temperature is decreased, however, solid solution of Nb-H starts to be precipitated. In this study, we show the first identified topographical features associated with nanometer-size hydride phase (Nb1-xHx) precipitates on metallic superconducting niobium using cryogenic-atomic force microscopy (AFM). Further, high energy grazing incidence X-ray diffraction reveals information regarding the structure and stoichiometry that these precipitates exhibit. Finally, through time-of-flight secondary ion mass spectroscopy (ToF-SIMS), we are able to locate atomic hydrogen sources near the top surface. This systematic study further explains localized degradation of RF superconductivity by the proximity effect due to hydrogen clusters

    Desalination by forward osmosis: Identifying performance limiting parameters through module-scale modeling

    Get PDF
    In this study, we analyze the effects of membrane properties, namely water permeability, solute permeability, and structural parameter, on the overall performance of an FO membrane module to extract water from simulated seawater (0.6 M NaCl). By considering the thermodynamic limit of operation, we demonstrate that the maximum achievable water recovery is practically independent of membrane properties, and higher maximum water recovery is achievable with counter-current compared to co-current mode. Analysis of the module-scale model indicates that reducing the support layer structural parameter offers substantial reductions in the membrane area required to achieve a specified water recovery. For example, a 25% reduction of the structural parameter of a state-of-the-art thin-film composite (TFC) membrane (from 400 to 300 μm) yields a sizable 20% reduction in membrane area. In contrast, quintupling the water permeability coefficient (from 2.0 to 10.0 L m−2 h−1 bar−1) of a modern TFC membrane generates only a modest 10% saving in membrane area. In addition, because of the permeability-selectivity trade-off that governs current polymeric membranes, doubling the water permeability coefficient would cause crippling ~7-fold increases in forward and reverse solute permeation. This quantitative study models the potential performance of a module-scale FO desalination process and firmly highlights the need to prioritize the reduction of support layer mass transport resistances over water permeability increases in membrane development

    Systematic Improvements in Transmon Qubit Coherence Enabled by Niobium Surface Encapsulation

    Full text link
    We present a novel transmon qubit fabrication technique that yields systematic improvements in T1_1 coherence times. We fabricate devices using an encapsulation strategy that involves passivating the surface of niobium and thereby preventing the formation of its lossy surface oxide. By maintaining the same superconducting metal and only varying the surface structure, this comparative investigation examining different capping materials and film substrates across different qubit foundries definitively demonstrates the detrimental impact that niobium oxides have on the coherence times of superconducting qubits, compared to native oxides of tantalum, aluminum or titanium nitride. Our surface-encapsulated niobium qubit devices exhibit T1_1 coherence times 2 to 5 times longer than baseline niobium qubit devices with native niobium oxides. When capping niobium with tantalum, we obtain median qubit lifetimes above 200 microseconds. Our comparative structural and chemical analysis suggests that amorphous niobium suboxides may induce higher losses. These results are in line with high-accuracy measurements of the niobium oxide loss tangent obtained with ultra-high Q superconducting radiofrequency (SRF) cavities. This new surface encapsulation strategy enables further reduction of dielectric losses via passivation with ambient-stable materials, while preserving fabrication and scalable manufacturability thanks to the compatibility with silicon processes

    Haploidentical vs. sibling, unrelated, or cord blood hematopoietic cell transplantation for acute lymphoblastic leukemia

    Get PDF
    The role of haploidentical hematopoietic cell transplantation (HCT) using posttransplant cyclophosphamide (PTCy) for acute lymphoblastic leukemia (ALL) is being defined. We performed a retrospective, multivariable analysis comparing outcomes of HCT approaches by donor for adults with ALL in remission. The primary objective was to compare overall survival (OS) among haploidentical HCTs using PTCy and HLA-matched sibling donor (MSD), 8/8 HLAmatched unrelated donor (MUD), 7 /8 HLA-MUD, or umbilical cord blood (UCB) HCT. Comparing haploidentical HCT to MSD HCT, we found that OS, leukemia-free survival (LFS), nonrelapse mortality (NRM), relapse, and acute graft-versus-host disease (aGVHD) were not different but chronic GVHD (cGVHD) was higher in MSD HCT. Compared with MUD HCT, OS, LFS, and relapse were not different, but MUD HCT had increased NRM (hazard ratio [HR], 1.42; P = .02), grade 3 to 4 aGVHD (HR, 1.59; P = .005), and cGVHD. Compared with 7/8 UD HCT, LFS and relapse were not different, but 7/8 UD HCT had worse OS (HR, 1.38; P = .01) and increased NRM (HR, 2.13; P <_ .001), grade 3 to 4 aGVHD (HR, 1.86; P = .003), and cGVHD (HR, 1.72; P <_ .001). Compared with UCB HCT, late OS, late LFS, relapse, and cGVHD were not different but UCB HCT had worse early OS (<_18 months; HR, 1.93; P < .001), worse early LFS (HR, 1.40; P = .007) and increased incidences of NRM (HR, 2.08; P < .001) and grade 3 to 4 aGVHD (HR, 1.97; P < .001). Haploidentical HCT using PTCy showed no difference in survival but less GVHD compared with traditional MSD and MUD HCT and is the preferred alternative donor HCT option for adults with ALL in complete remission

    Risk Factors for Graft-versus-Host Disease in Haploidentical Hematopoietic Cell Transplantation Using Post-Transplant Cyclophosphamide

    Get PDF
    Post-transplant cyclophosphamide (PTCy) has significantly increased the successful use of haploidentical donors with a relatively low incidence of graft-versus-host disease (GVHD). Given its increasing use, we sought to determine risk factors for GVHD after haploidentical hematopoietic cell transplantation (haplo-HCT) using PTCy. Data from the Center for International Blood and Marrow Transplant Research on adult patients with acute myeloid leukemia, acute lymphoblastic leukemia, myelodysplastic syndrome, or chronic myeloid leukemia who underwent PTCy-based haplo-HCT (2013 to 2016) were analyzed and categorized into 4 groups based on myeloablative (MA) or reduced-intensity conditioning (RIC) and bone marrow (BM) or peripheral blood (PB) graft source. In total, 646 patients were identified (MA-BM = 79, MA-PB = 183, RIC-BM = 192, RIC-PB = 192). The incidence of grade 2 to 4 acute GVHD at 6 months was highest in MA-PB (44%), followed by RIC-PB (36%), MA-BM (36%), and RIC-BM (30%) (P = .002). The incidence of chronic GVHD at 1 year was 40%, 34%, 24%, and 20%, respectively (P < .001). In multivariable analysis, there was no impact of stem cell source or conditioning regimen on grade 2 to 4 acute GVHD; however, older donor age (30 to 49 versus <29 years) was significantly associated with higher rates of grade 2 to 4 acute GVHD (hazard ratio [HR], 1.53; 95% confidence interval [CI], 1.11 to 2.12; P = .01). In contrast, PB compared to BM as a stem cell source was a significant risk factor for the development of chronic GVHD (HR, 1.70; 95% CI, 1.11 to 2.62; P = .01) in the RIC setting. There were no differences in relapse or overall survival between groups. Donor age and graft source are risk factors for acute and chronic GVHD, respectively, after PTCy-based haplo-HCT. Our results indicate that in RIC haplo-HCT, the risk of chronic GVHD is higher with PB stem cells, without any difference in relapse or overall survival

    Allogeneic Hematopoietic Cell Transplantation for Blastic Plasmacytoid Dendritic Cell Neoplasm: A CIBMTR Analysis

    Get PDF
    Blastic plasmacytoid dendritic cell neoplasm (BPDCN) is a rare hematological malignancy with a poor prognosis and considered incurable with conventional chemotherapy. Small observational studies reported allogeneic hematopoietic cell transplantation (allo-HCT) offers durable remissions in patients with BPDCN. We report an analysis of patients with BPDCN who received an allo-HCT, using data reported to the Center for International Blood and Marrow Transplant Research (CIBMTR). We identified 164 patients with BPDCN from 78 centers who underwent allo-HCT between 2007 and 2018. The 5-year overall survival (OS), disease-free survival (DFS), relapse, and nonrelapse mortality (NRM) rates were 51.2% (95% confidence interval [CI], 42.5-59.8), 44.4% (95% CI, 36.2-52.8), 32.2% (95% CI, 24.7-40.3), and 23.3% (95% CI, 16.9-30.4), respectively. Disease relapse was the most common cause of death. On multivariate analyses, age of ≥60 years was predictive for inferior OS (hazard ratio [HR], 2.16; 95% CI, 1.35-3.46; P = .001), and higher NRM (HR, 2.19; 95% CI, 1.13-4.22; P = .02). Remission status at time of allo-HCT (CR2/primary induction failure/relapse vs CR1) was predictive of inferior OS (HR, 1.87; 95% CI, 1.14-3.06; P = .01) and DFS (HR, 1.75; 95% CI, 1.11-2.76; P = .02). Use of myeloablative conditioning with total body irradiation (MAC-TBI) was predictive of improved DFS and reduced relapse risk. Allo-HCT is effective in providing durable remissions and long-term survival in BPDCN. Younger age and allo-HCT in CR1 predicted for improved survival, whereas MAC-TBI predicted for less relapse and improved DFS. Novel strategies incorporating allo-HCT are needed to further improve outcomes

    Probing Static and Dynamic Phenomena in Two-Dimensionally Confined Systems

    No full text

    An IoT and Machine Learning Approach for Site-specific Irrigation in Residential Irrigation Systems

    Get PDF
    Irrigation schedules on traditional irrigation controllers tend to disperse too much water by design and cause runoff, which results in wastage of water and pollution of water sources. Previous attempts at tackling this problem used expensive sensors that aren’t applicable to the residential landscape. In this thesis, we propose Weather-aware Runoff Prevention Irrigation Control (WaRPIC), a low-cost, practical solution that optimally applies water, while preventing runoff for each sprinkler zone. WaRPIC involves experiments conducted by homeowners on their landscape as part of a two-week data collection phase. The gathered data is used to build machine learning models that can accurately predict the Maximum Allowable Runtime (MAR) for each sprinkler zone given weather data obtained from a network of weather stations. We have also developed a low-cost module that can retrofit irrigation controllers in order to modify its irrigation schedule. We built a neural network-based model that predicts the MAR for any set of antecedent conditions, using data collected from a sprinkler zone. The model’s prediction is compared with a state-of-theart irrigation controller and the volume of water wasted by WaRPIC was only 2.6% of that of the state-of-the-art. We have deployed our modules at residences and estimate that the average homeowner can save 38,826 gallons of water over the course of May-Oct 2019, resulting in savings of $192
    • …
    corecore