63 research outputs found
Near infrared detectors for SNAP
Large format (1k x 1k and 2k x 2k) near infrared detectors manufactured by Rockwell Scientific Center and Raytheon Vision Systems are characterized as part of the near infrared R&D effort for SNAP (the Super-Nova/Acceleration Probe). These are hybridized HgCdTe focal plane arrays with a sharp high wavelength cut-off at 1.7 um. This cut-off provides a sufficiently deep reach in redshift while it allows at the same time low dark current operation of the passively cooled detectors at 140 K. Here the baseline SNAP near infrared system is briefly described and the science driven requirements for the near infrared detectors are summarized. A few results obtained during the testing of engineering grade near infrared devices procured for the SNAP project are highlighted. In particular some recent measurements that target correlated noise between adjacent detector pixels due to capacitive coupling and the response uniformity within individual detector pixels are discussed
Correlated Supernova Systematics and Ground Based Surveys
Supernova distances provide a direct probe of cosmic acceleration,
constraining dark energy. This leverage increases with survey redshift depth at
a rate bounded by the systematic uncertainties. We investigate the impact of a
wavelength-dependent, global correlation model of systematics in comparison to
the standard local-redshift correlation model. This can arise from subclass
uncertainties as features in the supernova spectrum redshift out of the
observer photometric filters or spectral range. We explore the impact of such a
systematic on ground-based supernova surveys such as Dark Energy Survey and
LSST, finding distinctive implications. Extending the wavelength sensitivity to
1.05 microns through "extreme red" CCDs can improve the dark energy figure of
merit by up to a factor 2.Comment: 8 pages, 5 figure
The M31 Globular Cluster Luminosity Function
We combine our compilation of photometry of M31 globular cluster and probable
cluster candidates with new near-infrared photometry for 30 objects. Using
these data we determine the globular cluster luminosity function (GCLF) in
multiple filters for the M31 halo clusters. We find a GCLF peak and dispersion
of V_0^0=16.84 +/-0.11, sigma_t=0.93 +/- 0.13 (Gaussian sigma = 1.20 +/- 0.14),
consistent with previous results. The halo GCLF peak colors (e.g., B^0_0 -
V^0_0) are consistent with the average cluster colors. We also measure V-band
GCLF parameters for several other subsamples of the M31 globular cluster
population. The inner third of the clusters have a GCLF peak significantly
brigher than that of the outer clusters (delta V =~ 0.5mag). Dividing the
sample by both galacticentric distance and metallicity, we find that the GCLF
also varies with metallicity, as the metal-poor clusters are on average 0.36
mag fainter than the metal-rich clusters. Our modeling of the catalog selection
effects suggests that they are not the cause of the measured differences, but a
more complete, less-contaminated M31 cluster catalog is required for
confirmation. Our results imply that dynamical destruction is not the only
factor causing variation in the M31 GCLF: metallicity, age, and cluster initial
mass function may also be important.Comment: AJ, in press. 36 pages, including 7 figure
Reducing Zero-point Systematics in Dark Energy Supernova Experiments
We study the effect of filter zero-point uncertainties on future supernova
dark energy missions. Fitting for calibration parameters using simultaneous
analysis of all Type Ia supernova standard candles achieves a significant
improvement over more traditional fit methods. This conclusion is robust under
diverse experimental configurations (number of observed supernovae, maximum
survey redshift, inclusion of additional systematics). This approach to
supernova fitting considerably eases otherwise stringent mission calibration
requirements. As an example we simulate a space-based mission based on the
proposed JDEM satellite; however the method and conclusions are general and
valid for any future supernova dark energy mission, ground or space-based.Comment: 30 pages,8 figures, 5 table, one reference added, submitted to
Astroparticle Physic
Weak Lensing from Space I: Instrumentation and Survey Strategy
A wide field space-based imaging telescope is necessary to fully exploit the
technique of observing dark matter via weak gravitational lensing. This first
paper in a three part series outlines the survey strategies and relevant
instrumental parameters for such a mission. As a concrete example of hardware
design, we consider the proposed Supernova/Acceleration Probe (SNAP). Using
SNAP engineering models, we quantify the major contributions to this
telescope's Point Spread Function (PSF). These PSF contributions are relevant
to any similar wide field space telescope. We further show that the PSF of SNAP
or a similar telescope will be smaller than current ground-based PSFs, and more
isotropic and stable over time than the PSF of the Hubble Space Telescope. We
outline survey strategies for two different regimes - a ``wide'' 300 square
degree survey and a ``deep'' 15 square degree survey that will accomplish
various weak lensing goals including statistical studies and dark matter
mapping.Comment: 25 pages, 8 figures, 1 table, replaced with Published Versio
Supernova / Acceleration Probe: A Satellite Experiment to Study the Nature of the Dark Energy
The Supernova / Acceleration Probe (SNAP) is a proposed space-based
experiment designed to study the dark energy and alternative explanations of
the acceleration of the Universe's expansion by performing a series of
complementary systematics-controlled measurements. We describe a
self-consistent reference mission design for building a Type Ia supernova
Hubble diagram and for performing a wide-area weak gravitational lensing study.
A 2-m wide-field telescope feeds a focal plane consisting of a 0.7
square-degree imager tiled with equal areas of optical CCDs and near infrared
sensors, and a high-efficiency low-resolution integral field spectrograph. The
SNAP mission will obtain high-signal-to-noise calibrated light-curves and
spectra for several thousand supernovae at redshifts between z=0.1 and 1.7. A
wide-field survey covering one thousand square degrees resolves ~100 galaxies
per square arcminute. If we assume we live in a cosmological-constant-dominated
Universe, the matter density, dark energy density, and flatness of space can
all be measured with SNAP supernova and weak-lensing measurements to a
systematics-limited accuracy of 1%. For a flat universe, the
density-to-pressure ratio of dark energy can be similarly measured to 5% for
the present value w0 and ~0.1 for the time variation w'. The large survey area,
depth, spatial resolution, time-sampling, and nine-band optical to NIR
photometry will support additional independent and/or complementary dark-energy
measurement approaches as well as a broad range of auxiliary science programs.
(Abridged)Comment: 40 pages, 18 figures, submitted to PASP, http://snap.lbl.go
In Search of ISO: An Institutional Perspective on the Adoption of International Management Standards
Effects of Anacetrapib in Patients with Atherosclerotic Vascular Disease
BACKGROUND:
Patients with atherosclerotic vascular disease remain at high risk for cardiovascular events despite effective statin-based treatment of low-density lipoprotein (LDL) cholesterol levels. The inhibition of cholesteryl ester transfer protein (CETP) by anacetrapib reduces LDL cholesterol levels and increases high-density lipoprotein (HDL) cholesterol levels. However, trials of other CETP inhibitors have shown neutral or adverse effects on cardiovascular outcomes.
METHODS:
We conducted a randomized, double-blind, placebo-controlled trial involving 30,449 adults with atherosclerotic vascular disease who were receiving intensive atorvastatin therapy and who had a mean LDL cholesterol level of 61 mg per deciliter (1.58 mmol per liter), a mean non-HDL cholesterol level of 92 mg per deciliter (2.38 mmol per liter), and a mean HDL cholesterol level of 40 mg per deciliter (1.03 mmol per liter). The patients were assigned to receive either 100 mg of anacetrapib once daily (15,225 patients) or matching placebo (15,224 patients). The primary outcome was the first major coronary event, a composite of coronary death, myocardial infarction, or coronary revascularization.
RESULTS:
During the median follow-up period of 4.1 years, the primary outcome occurred in significantly fewer patients in the anacetrapib group than in the placebo group (1640 of 15,225 patients [10.8%] vs. 1803 of 15,224 patients [11.8%]; rate ratio, 0.91; 95% confidence interval, 0.85 to 0.97; P=0.004). The relative difference in risk was similar across multiple prespecified subgroups. At the trial midpoint, the mean level of HDL cholesterol was higher by 43 mg per deciliter (1.12 mmol per liter) in the anacetrapib group than in the placebo group (a relative difference of 104%), and the mean level of non-HDL cholesterol was lower by 17 mg per deciliter (0.44 mmol per liter), a relative difference of -18%. There were no significant between-group differences in the risk of death, cancer, or other serious adverse events.
CONCLUSIONS:
Among patients with atherosclerotic vascular disease who were receiving intensive statin therapy, the use of anacetrapib resulted in a lower incidence of major coronary events than the use of placebo. (Funded by Merck and others; Current Controlled Trials number, ISRCTN48678192 ; ClinicalTrials.gov number, NCT01252953 ; and EudraCT number, 2010-023467-18 .)
Imprint of DESI fiber assignment on the anisotropic power spectrum of emission line galaxies
- …