4,170 research outputs found

    A mathematical model of interleukin-6 dynamics during exercise

    Get PDF
    Physical exercise is known to reduce the chronic inflammatory status that leads to Type 2 Diabetes. Its beneficial effects seem to be exerted trough a primary production of the cytokine Interleukin-6 (IL-6) which triggers a cascade of anti-inflammatory cytokines. Consequently, IL-6 has a central role in the description of the metabolic effects of exercise. The aim of this study was to develop a model of IL-6 dynamics during exercise. A model constituted by two non-linear differential equations is proposed. Since IL-6 production seems to be dependent not only on exercise duration but also on exercise intensity, input to the model is represented by heart rate, which is known to correlate well with exercise intensity. Model implementation in a Matlab-based parametric identification procedure allowed optimization of adjustable characteristic coefficients of IL-6 dynamics during exercise. From the reported results, it can be concluded that this model is a suitable tool to reproduce IL-6 time course during the execution of a physical exercise. This model was the first step of a project aimed at describing the complete immune system response to exercise and at giving a comprehensive sight of the effects that exercise has on the metabolic system

    A system model of the effects of exercise on plasma Interleukin-6 dynamics in healthy individuals: Role of skeletal muscle and adipose tissue

    Get PDF
    Interleukin-6 (IL-6) has been recently shown to play a central role in glucose homeostasis, since it stimulates the production and secretion of Glucagon-like Peptide-1 (GLP-1) from intestinal L-cells and pancreas, leading to an enhanced insulin response. In resting conditions, IL-6 is mainly produced by the adipose tissue whereas, during exercise, skeletal muscle contractions stimulate a marked IL-6 secretion as well. Available mathematical models describing the effects of exercise on glucose homeostasis, however, do not account for this IL-6 contribution. This study aimed at developing and validating a system model of exercise’s effects on plasma IL-6 dynamics in healthy humans, combining the contributions of both adipose tissue and skeletal muscle. A two-compartment description was adopted to model plasma IL-6 changes in response to oxygen uptake’s variation during an exercise bout. The free parameters of the model were estimated by means of a cross-validation procedure performed on four different datasets. A low coefficient of variation (<10%) was found for each parameter and the physiologically meaningful parameters were all consistent with literature data. Moreover, plasma IL-6 dynamics during exercise and post-exercise were consistent with literature data from exercise protocols differing in intensity, duration and modality. The model successfully emulated the physiological effects of exercise on plasma IL-6 levels and provided a reliable description of the role of skeletal muscle and adipose tissue on the dynamics of plasma IL-6. The system model here proposed is suitable to simulate IL-6 response to different exercise modalities. Its future integration with existing models of GLP-1-induced insulin secretion might provide a more reliable description of exercise’s effects on glucose homeostasis and hence support the definition of more tailored interventions for the treatment of type 2 diabetes

    correction formula approach to evaluate fatigue damage induced by non gaussian stress state

    Get PDF
    Abstract In the present paper the authors define an original analytical expression of a corrective coefficient to evaluate fatigue damage induced by a non-Gaussian stress state affected by high Kurtosis (values higher than 5) and by zero Skewness. This approach starts from a previous activity in which the authors solved an analogous problem but for light non-Gaussian stress states (Kurtosis value less than 5). The proposed procedure assumes to know the fatigue damage induced by Gaussian equivalent stress state time domain process. This characteristic allows the proposed procedure to be easily adopted inside the so-called Frequency Domain Fatigue Methods but in parallel with the statistical analysis of the system time domain response (Kurtosis and Skewness evaluation). Interesting considerations about its applicability will be proposed as concerns the non-Gaussianity and non-Stationarity of the inputs when the system is a flexible component excited in its frequency range

    evaluation of fatigue damage with an energy criterion of simple implementation

    Get PDF
    Abstract Many theoretical methods for multiaxial fatigue life prediction are present in literature, most of them based on their effectiveness on knowledge of the entire stress time history. This represents the great applicative limit. The incapacity to study real situations, not only deterministic one, let the authors to develop a simple and rigorous criterion, which helps the designer who works in this area. The criterion is presented focusing the attention on the basic premise, highlighting its applicability, its practicality and its computational power. To do that, the Authors take into account the deterministic or random character of the individual constraint components and their degree of correlation. In order to verify the method, simulations of multiaxial loads conditions, developed in the time domain, will be carried out with various correlation levels between the stress components on which the method will be applied

    Estimation of Tidal Volume during Exercise Stress Test from Wearable-Device Measures of Heart Rate and Breathing Rate

    Get PDF
    Tidal volume (TV), defined as the amount of air that moves in or out of the lungs with each respiratory cycle, is important in evaluating the respiratory function. Although TV can be reliably measured in laboratory settings, this information is hardly obtainable under everyday living conditions. Under such conditions, wearable devices could provide valuable support to monitor vital signs, such as heart rate (HR) and breathing rate (BR). The aim of this study was to develop a model to estimate TV from wearable-device measures of HR and BR during exercise. HR and BR were acquired through the Zephyr Bioharness 3.0 wearable device in nine subjects performing incremental cycling tests. For each subject, TV during exercise was obtained with a metabolic cart (Cosmed). A stepwise regression algorithm was used to create the model using as possible predictors HR, BR, age, and body mass index; the model was then validated using a leave-one-subject-out cross-validation procedure. The performance of the model was evaluated using the explained variance (R-2), obtaining values ranging from 0.65 to 0.72. The proposed model is a valid method for TV estimation with wearable devices and can be considered not subject-specific and not instrumentation-specific

    Initial investigation of athletes’ electrocardiograms acquired by wearable sensors during the pre-exercise phase

    Get PDF
    Aim: The aim of this study is to support large-scale prevention programs fighting sport-related sudden cardiac death by providing a set of electrocardiographic features representing a starting point in the development of normal reference values for the pre-exercise phase. Background: In people with underlying, often unknown, cardiovascular abnormalities, increased cardiovascular load during exercise can trigger sport-related sudden cardiac death. Prevention remains the only weapon to contrast sport-related sudden cardiac death. So far, no reference values have been proposed for electrocardiograms of athletes acquired with wearable sensors in the pre-exercise phase, consisting of the few minutes immediately before the beginning of the training session. Objective: To perform an initial investigation of athletes’ electrocardiograms acquired by wearable sensors during the pre-exercise phase. Methods: The analyzed electrocardiograms, acquired through BioHarness 3.0 by Zephyr, belong to 51 athletes (Sport Database and Cycling Database of the Cardiovascular Bioengineering Lab of the Università Politecnica delle Marche, Italy). Preliminary values consist of interquartile ranges of six electrocardiographic features which are heart rate, heart-rate variability, QRS duration, ST level, QT interval, and corrected QT interval. Results: For athletes 35 years old or younger, preliminary values were [72;91]bpm, [26;47]ms, [85;104]ms, [-0.08;0.08]mm, [326;364]ms and [378;422]ms, respectively. For athletes older than 35 years old, preliminary values were [71;94]bpm, [16;65]ms, [85;100]ms, [-0.11;0.07]mm, [330;368]ms and [394;414]ms, respectively. Conclusion: Availability of preliminary reference values could help identify those athletes who, due to electrocardiographic features out of normal ranges, are more likely to develop cardiac complications that may lead to sport-related sudden cardiac death

    Ruolo della chirurgia endovascolare nelle rotture aortiche del politraumatizzato con lesioni polidistrettuali di pertinenza chirurgica

    Get PDF
    Nel politraumatizzato con gravi lesioni polidistrettuali di interesse chirurgico il trattamento endovascolare (TEV) della rottura posttraumatica dell’ aorta toracica (RPAT) rappresenta oggi una valida alternativa terapeutica al trattamento chirurgico convenzionale. Nella nostra esperienza (ottobre 2001-novembre 2004) abbiamo osservato 5 casi di RPAT (3 rotture istmiche, 2 rotture aorta toracica discendente) in gravi politraumatizzati, tutti di sesso maschile, di etĂ  compresa fra i 23 ed i 42 anni (media 32,4), trattate con successo con TEV. Il Glasgow Coma Score (GCS) era compreso fra 5 e 13. Tutti i pazienti sono stati sottoposti, dopo adeguata stabilizzazione del quadro clinico-emodinamico, ad angio-TC total body al fine di valutare la lesione aortica ed identificare le altre lesioni associate. In 4 casi erano coinvolti piĂč distretti corporei di pertinenza chirurgica (3 casi: trauma osseo, addominale e neurochirurgico; 1 caso: trauma osseo, addominale, neurochirurgico e toracico). Il TEV Ăš stato eseguito sempre in sala operatoria previa arteriografia digitale. La durata media della procedura angio-radiologica Ăš stata di 105 minuti (range 80 - 125). Non si Ăš verificata nessuna complicanza nĂ© immediata nĂ© a distanza (follow-up = medio 24 mesi; range 12-36). In conclusione il TEV delle RPAT offre in pazienti ‘critici’ una valida opzione terapeutica alla chirurgia tradizionale in grado di stabilizzare il quadro clinico e trattare successivamente ‘in sicurezza’ le altre gravi lesioni chirurgiche associate

    Long-range correlation and multifractality in Bach's Inventions pitches

    Full text link
    We show that it can be considered some of Bach pitches series as a stochastic process with scaling behavior. Using multifractal deterend fluctuation analysis (MF-DFA) method, frequency series of Bach pitches have been analyzed. In this view we find same second moment exponents (after double profiling) in ranges (1.7-1.8) in his works. Comparing MF-DFA results of original series to those for shuffled and surrogate series we can distinguish multifractality due to long-range correlations and a broad probability density function. Finally we determine the scaling exponents and singularity spectrum. We conclude fat tail has more effect in its multifractality nature than long-range correlations.Comment: 18 page, 6 figures, to appear in JSTA

    Enhanced adaptive matched filter for automated identification and measurement of electrocardiographic alternans

    Get PDF
    Electrocardiographic alternans, consisting of P-wave alternans (PWA), QRS-complex alternans (QRSA) and Twave alternans (TWA), is an index of cardiac risk. However, only automated TWA measurement methods have been proposed so far. Here, we presented the enhanced adaptive matched filter (EAMF) method and tested its reliability in both simulated and experimental conditions. Our methodological novelty consists in the introduction of a signal enhancement procedure according to which all sections of the electrocardiogram (ECG) but the wave of interest are set to baseline, and in the extraction of the alternans area (AAr) in addition to the standard alternans amplitude (AAm). Simulated data consisted of 27 simulated ECGs representing all combinations of PWA, QRSA and TWA of low (10 mu V) and high (100 mu V) amplitude. Experimental data consisted of exercise 12-lead ECGs from 266 heart failure patients with an implanted cardioverter defibrillator for primary prevention. EAMF was able to accurately identify and measure all kinds of simulated alternans (absolute maximum error equal to 2%). Moreover, different alternans kinds were simultaneously present in the experimental data and EAMF was able to identify and measure all of them (AAr: 545 mu V x ms, 762 mu V x ms and 1382 mu V x ms; AAm: 5 mu V, 9 mu V and 7 mu V; for PWA, QRSA and TWA, respectively) and to discriminate TWA as the prevalent one (with the highest AAr). EAMF accurately identifies and measures all kinds of electrocardiographic alternans. EAMF may support determination of incremental clinical utility of PWA and QRSA with respect to TWA only.Cardiolog

    Prototype ATLAS IBL Modules using the FE-I4A Front-End Readout Chip

    Get PDF
    The ATLAS Collaboration will upgrade its semiconductor pixel tracking detector with a new Insertable B-layer (IBL) between the existing pixel detector and the vacuum pipe of the Large Hadron Collider. The extreme operating conditions at this location have necessitated the development of new radiation hard pixel sensor technologies and a new front-end readout chip, called the FE-I4. Planar pixel sensors and 3D pixel sensors have been investigated to equip this new pixel layer, and prototype modules using the FE-I4A have been fabricated and characterized using 120 GeV pions at the CERN SPS and 4 GeV positrons at DESY, before and after module irradiation. Beam test results are presented, including charge collection efficiency, tracking efficiency and charge sharing.Comment: 45 pages, 30 figures, submitted to JINS
    • 

    corecore