10 research outputs found

    The comparative in situ hygrothermal performance of Hemp and Stone Wool insulations in vapour open timber frame wall panels

    Get PDF
    An in situ experiment in a full scale timber frame test building was carried out to compare the hygrothermal performance of Hemp and Stone Wool insulations of identical thermal conductivity. Hemp and Stone Wool insulations were installed in timber frame wall panels without vapour barrier. The comparison was made in terms of heat transfer properties, likelihood of mould growth and condensation. Step changes in internal relative humidity were performed to explore the effect of high and normal internal moisture load on the wall panels. No significant difference between the average equivalent thermal transmittance (U-values) of the panels incorporating Hemp and Stone Wool insulations was observed. The average equivalent U-values of the panels were closer to the calculated U-values of the panels based on the manufacturers’ declared thermal conductivity of Hemp and Stone Wool insulations. It was observed that the placement of heat flux sensor along the depth of the insulation had significant influence on the measured equivalent U-value of the panels during high internal moisture load. The frequency and likelihood of condensation was higher in the interface of Stone Wool and Oriented Strand Board (OSB). In terms of the parametric assessment of mould germination potential, relative humidity, temperature and exposure conditions in the insulation-OSB interfaces were found to be favourable to germination of mould spore. However, when the insulations were dismantled, no mould was visually detected

    Hygric properties of hemp bio-insulations with differing compositions

    Get PDF
    The paper presents the results of a laboratory investigation on the hygric properties of five hemp insulation materials commercially available in the UK. The hemp fibre content varies between 30% and 95% in the total fibre content of the insulation materials examined. The adsorption–desorption isotherm, moisture buffer value, vapour diffusion resistance factor and water absorption coefficient were determined for the insulation materials investigated. The results showed that the hygric properties of the hemp insulation materials could vary widely depending on the constituents and fibrous structure. The considerable differences noted in the hygric properties of the insulation materials examined could potentially influence their hygrothermal performance as part of a building thermal envelope

    Hygrothermal performance of wood-hemp insulation in timber frame wall panels with and without a vapour barrier

    Get PDF
    An in situ experiment on a full-scale timber frame test building was carried out to study the hygrothermal performance of wood-hemp composite insulation in timber frame wall panels with and without a vapour barrier. The heat transfer properties and the likelihood of mould growth and condensation in the panels were compared. Step changes in the internal relative humidity were performed to explore the effects of high, normal and low internal moisture loads on the wall panels. No significant difference in the average equivalent thermal transmittance (U-values) between the panels with and without a vapour barrier was observed. The average equivalent U-values of the panels were close to the U-values calculated from the manufacturers’ declared thermal conductivity values of the insulation. The likelihood of condensation was higher at the interface of the wood-hemp insulation and the oriented strand board (OSB) in the panel without a vapour barrier. In terms of the parametric assessment of the mould germination potential, the relative humidity, the temperature and the exposure conditions in the insulation-OSB interfaces of the panel without a vapour barrier were found to be more favourable to the germination of mould spores. Nonetheless, when the insulations were dismantled, no mould was visually detected

    Quasi steady state and dynamic hygrothermal performance of fibrous Hemp and Stone Wool insulations: Two innovative laboratory based investigations

    Get PDF
    Moisture and heat management properties of Hemp and Stone Wool insulations were studied by mounting them between a hot and a cold climate chamber. Both insulations were exposed to identical hygrothermal boundary conditions. Quasi steady state and dynamic tests were carried out at a range of relative humidity exposures. The likelihood of interstitial condensation was assessed and equivalent thermal conductivity values of the insulations were determined. The adsorption-desorption isotherms of the insulations were also determined in a dynamic vapour sorption (DVS) instrument. It was observed that the likelihood of condensation was higher in Stone Wool insulation than in Hemp insulation. Hemp insulation performed better in managing moisture due to its high hygric inertia and water absorption capacity. It was observed that the equivalent thermal conductivity of Stone Wool insulation was dependent on enthalpy flow and phase change of moisture. The equivalent thermal conductivity of Hemp insulation was close to its declared thermal conductivity in dynamic conditions when high relative humidity exposures were transient. In quasi steady state boundary conditions, when the insulation was allowed to reach the equilibrium moisture content at ranges of relative humidity, there was a moisture dependent increase of thermal conductivity in Hemp insulation

    Asymptotic Stability versus Exponential Stability in Linear Volterra Difference Equations of Convolution Type(The Functional and Algebraic Method for Differential Equations)

    Get PDF
    This article examines the effectiveness of two innovative retrofitting solutions at enhancing the seismic behaviour of a substandard reinforced concrete building tested on a shake table as part of the Pan-European funded project BANDIT. To simulate typical substandard construction, the reinforcement of columns and beam-column joints of the full-scale structure had inadequate detailing. An initial series of shake table tests were carried out to assess the seismic behaviour of the bare building and the effectiveness of a first retrofitting intervention using Post-Tensioned Metal Straps. After these tests, columns and joints were repaired and subsequently retrofitted using a retrofitting solution consisting of Carbon Fibre Reinforced Polymers and Post-Tensioned Metal Straps applied on opposite frames of the building. The building was then subjected to unidirectional and three-dimensional incremental seismic excitations to assess the effectiveness of the two retrofitting solutions at improving the global and local building performance. The article provides details of the above shake table testing programme and retrofitting solutions, and discusses the test results in terms of the observed damage, global damage indexes, performance levels and local strains. It is shown that whilst the original bare building was significantly damaged at a peak ground acceleration (PGA) of 0.15 g, the retrofitted building resisted severe three-dimensional shake table tests up to PGA = 0.60 g without failure. Moreover, the retrofitting intervention enhanced the interstorey drift ratio capacity of the 1st and 2nd floors by 160 and 110 %, respectively. Therefore, the proposed dual retrofitting system is proven to be very effective for improving the seismic performance of substandard buildings

    Data Quality Challenges in Large-Scale Cyber-Physical Systems: a Systematic Review

    No full text
    Cyber-physical systems (CPSs) are integrated systems engineered to combine computational control algorithms and physical components such as sensors and actuators, effectively using an embedded communication core. Smart cities can be viewed as large-scale, heterogeneous CPSs that utilise technologies like the Internet of Things (IoT), surveillance, social media, and others to make informed decisions and drive the innovations of automation in urban areas. Such systems incorporate multiple layers and complex structure of hardware, software, analytical algorithms, business knowledge and communication networks, and operate under noisy and dynamic conditions. Thus, large-scale CPSs are vulnerable to enormous technical and operational challenges that may compromise the quality of data of their applications and accordingly reduce the quality of their services. This paper presents a systematic literature review to investigate data quality challenges in smart-cities large-scale CPSs and to identify the most common techniques used to address these challenges. This systematic literature review showed that significant work had been conducted to address data quality management challenges in smart cities, large-scale CPS applications. However, still, more is required to provide a practical, comprehensive data quality management solution to detect errors in sensor nodes’ measurements associated with the main data quality dimensions of accuracy, timeliness, completeness, and consistency. No systematic or generic approach was demonstrated for detecting sensor nodes and sensor node networks failures in large-scale CPS applications. Moreover, further research is required to address the challenges of ensuring the quality of the spatial and temporal contextual attributes of sensor nodes’ observations

    Contribution numérique pour l’optimisation d’un mode opératoire de soudage – Identification d’une source de chaleur équivalente

    No full text
    The effectiveness of a novel Post-Tensioned Metal Strapping (PTMS) technique at enhancing the seismic behavior of a substandard RC building was investigated through full-scale, shake-table tests during the EU-funded project BANDIT. The building had inadequate reinforcement detailing in columns and joints to replicate old construction practices. After the bare building was initially damaged significantly, it was repaired and strengthened with PTMS to perform additional seismic tests. The PTMS technique improved considerably the seismic performance of the tested building. While the bare building experienced critical damage at an earthquake of PGA = 0.15 g, the PTMS-strengthened building sustained a PGA = 0.35 g earthquake without compromising stability

    Shake table tests on deficient RC buildings strengthened using post-tensioned metal straps

    No full text
    The European research project BANDIT investigated the effectiveness of a novel Post-Tensioned Metal Strapping (PTMS) strengthening technique at improving the seismic performance of deficient RC buildings using shake table tests. A full-scale two-story structure was designed with inadequate reinforcement detailing of columns and beam-column joints so as to simulate typical deficient buildings in Mediterranean and developing countries. Initial shaking table tests were carried out until significant damage was observed in the beam-column joints
    corecore