16 research outputs found

    On the application of Two-Photon Absorption for Laser Fault Injection attacks

    Get PDF
    Laser Fault Injection (LFI) is considered to be the most powerful semiinvasive fault injection method for implementation attacks on security devices. In this work we discuss for the first time the application of the nonlinear Two-Photon Absorption (TPA) effect for the purpose of LFI. Though TPA is an established technique in other areas, e.g. fluorescence microscopy, so far it did not receive any attention in the field of physical attack methods on integrated circuits. We show that TPA has several superior properties over the regular linear LFI method. The TPA effect allows to work on non-thinned devices without increasing the induced energy and hence the stress on the device. In contrast to regular LFI, the nonlinearity of the TPA effect leads to increased precision due to the steeper descent in intensity and also a vertically restricted photoelectric effect. By practical experiments, we demonstrate the general applicability of the method for a specific device and that unlike a regular LFI setup, TPA-LFI is capable to inject faults without triggering a latch-up effect. In addition we discuss the possible implications of TPA-LFI on various sensor-based countermeasures

    European association for endoscopic surgery (EAES) consensus statement on single-incision endoscopic surgery

    Get PDF
    Laparoscopic surgery changed the management of numerous surgical conditions. It was associated with many advantages over open surgery, such as decreased postoperative pain, faster recovery, shorter hospital stay and excellent cosmesis. Since two decades single-incision endoscopic surgery (SIES) was introduced to the surgical community. SIES could possibly result in even better postoperative outcomes than multi-port laparoscopic surgery, especially concerning cosmetic outcomes and pain. However, the single-incision surgical procedure is associated with quite some challenges.This article is freely available via Open Access, click on the Publisher's URL to access the full-text.Publishe

    Reducing the environmental impact of surgery on a global scale: systematic review and co-prioritization with healthcare workers in 132 countries

    Get PDF
    Abstract Background Healthcare cannot achieve net-zero carbon without addressing operating theatres. The aim of this study was to prioritize feasible interventions to reduce the environmental impact of operating theatres. Methods This study adopted a four-phase Delphi consensus co-prioritization methodology. In phase 1, a systematic review of published interventions and global consultation of perioperative healthcare professionals were used to longlist interventions. In phase 2, iterative thematic analysis consolidated comparable interventions into a shortlist. In phase 3, the shortlist was co-prioritized based on patient and clinician views on acceptability, feasibility, and safety. In phase 4, ranked lists of interventions were presented by their relevance to high-income countries and low–middle-income countries. Results In phase 1, 43 interventions were identified, which had low uptake in practice according to 3042 professionals globally. In phase 2, a shortlist of 15 intervention domains was generated. In phase 3, interventions were deemed acceptable for more than 90 per cent of patients except for reducing general anaesthesia (84 per cent) and re-sterilization of ‘single-use’ consumables (86 per cent). In phase 4, the top three shortlisted interventions for high-income countries were: introducing recycling; reducing use of anaesthetic gases; and appropriate clinical waste processing. In phase 4, the top three shortlisted interventions for low–middle-income countries were: introducing reusable surgical devices; reducing use of consumables; and reducing the use of general anaesthesia. Conclusion This is a step toward environmentally sustainable operating environments with actionable interventions applicable to both high– and low–middle–income countries

    Reducing the environmental impact of surgery on a global scale: systematic review and co-prioritization with healthcare workers in 132 countries

    Get PDF
    Background Healthcare cannot achieve net-zero carbon without addressing operating theatres. The aim of this study was to prioritize feasible interventions to reduce the environmental impact of operating theatres. Methods This study adopted a four-phase Delphi consensus co-prioritization methodology. In phase 1, a systematic review of published interventions and global consultation of perioperative healthcare professionals were used to longlist interventions. In phase 2, iterative thematic analysis consolidated comparable interventions into a shortlist. In phase 3, the shortlist was co-prioritized based on patient and clinician views on acceptability, feasibility, and safety. In phase 4, ranked lists of interventions were presented by their relevance to high-income countries and low–middle-income countries. Results In phase 1, 43 interventions were identified, which had low uptake in practice according to 3042 professionals globally. In phase 2, a shortlist of 15 intervention domains was generated. In phase 3, interventions were deemed acceptable for more than 90 per cent of patients except for reducing general anaesthesia (84 per cent) and re-sterilization of ‘single-use’ consumables (86 per cent). In phase 4, the top three shortlisted interventions for high-income countries were: introducing recycling; reducing use of anaesthetic gases; and appropriate clinical waste processing. In phase 4, the top three shortlisted interventions for low–middle-income countries were: introducing reusable surgical devices; reducing use of consumables; and reducing the use of general anaesthesia. Conclusion This is a step toward environmentally sustainable operating environments with actionable interventions applicable to both high– and low–middle–income countries

    On the application of Two-Photon Absorption for Laser Fault Injection attacks: Pushing the physical boundaries for Laser-based Fault Injection

    No full text
    Laser Fault Injection (LFI) is considered to be the most powerful semiinvasive fault injection method for implementation attacks on security devices. In this work we discuss for the first time the application of the nonlinear Two-Photon Absorption (TPA) effect for the purpose of LFI. Though TPA is an established technique in other areas, e.g. fluorescence microscopy, so far it did not receive any attention in the field of physical attack methods on integrated circuits. We show that TPA has several superior properties over the regular linear LFI method. The TPA effect allows to work on non-thinned devices without increasing the induced energy and hence the stress on the device. In contrast to regular LFI, the nonlinearity of the TPA effect leads to increased precision due to the steeper descent in intensity and also a vertically restricted photoelectric effect. By practical experiments, we demonstrate the general applicability of the method for a specific device and that unlike a regular LFI setup, TPA-LFI is capable to inject faults without triggering a latch-up effect. In addition we discuss the possible implications of TPA-LFI on various sensor-based countermeasures

    The Shift from Multiport to Single Port Increases the Amount of Bleeding in Laparoscopic Major Hepatectomy

    No full text
    Background: Bleeding is a negative outcome predictor in liver surgery. Reduction in the abdominal wall trauma in major hepatectomy is challenging but might offer possible benefits for the patient. This study was conducted to assess hemostasis techniques in single-port major hepatectomies (SP-MajH) as compared to multiport major hepatectomies (MP-MajH). Methods: The non-randomized study comprised 34 SP-MajH in selected patients; 14 MP-MajH served as the control group. Intraoperative blood loss and number of blood units transfused served as the primary endpoints. Secondary endpoints were complications and oncologic five-year outcome. Results: All resections were completed without converting to open surgery. Time for hepatectomy did not differ between SP-MajH and MP-MajH. Blood loss and number of patients with blood loss > 25 mL were significantly larger in MP-MajH (p = 0.001). In contrast, bleeding control was more difficult in SP-MajH, resulting in more transfusions (p = 0.008). One intestinal laceration (SP-MajH) accounted for the only intraoperative complication; 90-day mortality was zero. Postoperative complications were noted in total in 20.6% and 21.4% of patients for SP-MajH and MP-MajH, respectively. No incisional hernia occurred. During a median oncologic follow-up at 61 and 56 months (SP-MajH and MP-MajH), no local tumor recurrence was observed. Conclusions: SP-MajH requires sophisticated techniques to ensure operative safety. Substantial blood loss requiring transfusion is more likely to occur in SP-MajH than in MP-MajH

    Water jet space charge spectroscopy: route to direct measurement of electron dynamics for organic systems in their natural environment

    No full text
    The toolbox for time-resolved direct measurements of electron dynamics covers a variety of methods. Since the experimental effort is increasing rapidly with achievable time resolution, there is an urge for simple and robust measurement techniques. Within this paper prove-of-concept experiments and numerical simulations are utilized to investigate the applicability of a new setup for the generation of ultrashort electron pulses in the energy range of 300 eV up to 1.6 keV. The experimental approach combines an in-vacuum liquid microjet and a few-cycle femtosecond laser system, while the threshold for electron impact ionization serves as a gate for the effective electron pulse duration. The experiments prove that electrons in the keV regime are accessible and that the electron spectrum can be easily tuned by laser intensity and focal position alignment with respect to the water jet. Numerical simulations show that a sub-picosecond temporal resolution is achievable

    Ultrafast quantum control of ionization dynamics

    No full text
    The unprecedented combination of transient absorption and ion mass spectroscopy with attosecond resolution is used to study and control the complex multidimensional excitation and decay cascade of an ultrafast Auger process in krypton

    Ultrafast quantum control of ionization dynamics in krypton

    Get PDF
    Photoionization of atoms and molecules is a complex process and requires sensitive probes to explore the ultrafast dynamics. Here the authors combine transient absorption and photo-ion spectroscopy methods to explore and control the attosecond pulse initiated excitation, ionization and Auger decay in Kr atoms
    corecore