57 research outputs found

    Ariel - Volume 9 Number 1

    Get PDF
    Executive Editor Emily Wofford Business Manager Fredric Jay Matlin University News John Patrick Welch World News George Robert Coar Editorial Editor Steve Levine Feature Brad Feldstein Mark Rubin Graphics Steve Hulkower Photo Rick Spaide Circulation Lee Wugofsk

    A double-reprocessing high-level disinfection protocol does not eliminate positive cultures from the elevators of duodenoscopes

    Get PDF
    Background and study aim Duodenoscopes have been the source of serious infection, despite correct performance of high-level disinfection (HLD). This study aimed to observe the impact of performing HLD twice on the rate of positive cultures from duodenoscope elevators. Methods We performed double HLD (DHLD; i. e. complete manual cleaning followed by automated reprocessing, with the entire process repeated) and then randomly cultured the elevators of our duodenoscopes on about 30 % of occasions. Results DHLD was associated with positive elevator cultures for any microorganism in 9.4 % of cases, with a 0.8 % rate of known pathogens (627 cultures) between May 2015 and February 2016. After February 2016, and in association with changing the precleaning fluid, as well as use of a new FDA-recommended cleaning brush, the rate of positive cultures for any microorganism after DHLD was 4.8 % and 0.2 % for known pathogens (420 cultures). In a third phase, characterized by a change in personnel performing DHLD and retirement of a duodenoscope with a high rate of positive cultures, the rate of positive cultures for any microorganism was 4.9 % (783 cultures) and the rate of positive culture for known pathogens was 0.3 %. To our knowledge, no duodenoscope transmission of infection occurred during the study interval. Conclusions DHLD resulted in a low rate of positive cultures for known pathogens and for organisms of low pathogenic potential, but did not eliminate these, from duodenoscope elevators. Additional improvements in HLD protocols and/or duodenoscope design are needed

    Digital Simulation for Automobile Maneuvers

    Full text link
    A new all-digital simulation of automobile handling allows severe maneuvers involving braking or accel eration and cornering. A novel feature is the in corporation of closed-loop control based on a mathematical model of the human driver. The program is modular and well-documented. The model includes provisions for nonlinear tire and suspension forces and moments; it also allows the user to switch off the nonlinearities and to include an antilock brake system.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/68886/2/10.1177_003754978103700304.pd

    Narrow-band imaging versus white light for the detection of proximal colon serrated lesions: a randomized, controlled trial

    Get PDF
    Background The value of narrow-band imaging (NBI) for detecting serrated lesions is unknown. Objective To assess NBI for the detection of proximal colon serrated lesions. Design Randomized, controlled trial. Setting Two academic hospital outpatient units. Patients Eight hundred outpatients 50 years of age and older with intact colons undergoing routine screening, surveillance, or diagnostic examinations. Interventions Randomization to colon inspection in NBI versus white-light colonoscopy. Main Outcome Measurements The number of serrated lesions (sessile serrated polyps plus hyperplastic polyps) proximal to the sigmoid colon. Results The mean inspection times for the whole colon and proximal colon were the same for the NBI and white-light groups. There were 204 proximal colon lesions in the NBI group and 158 in the white light group (P = .085). Detection of conventional adenomas was comparable in the 2 groups. Limitations Lack of blinding, endoscopic estimation of polyp location. Conclusion NBI may increase the detection of proximal colon serrated lesions, but the result in this trial did not reach significance. Additional study of this issue is warranted. (Clinical trial registration number: NCT01572428.

    Impact of a ring fitted cap on insertion time and adenoma detection: a randomized controlled trial

    Get PDF
    Background and Aims: Devices for flattening colon folds can improve polyp detection at colonoscopy. However, there are few data on the endoscopic ring fitted cap (EndoRings, EndoAid, Caesarea, Israel). We sought to compare adenoma detection with EndoRings with that of standard high-definition colonoscopy. Methods: A single-center randomized controlled trial of 562 patients (284 randomized to EndoRings and 278 to standard colonoscopy) at 2 outpatient endoscopy units in the Indiana University Hospital system. Adenoma detection was the primary outcome measured as adenoma detection rate (ADR) and adenomas per colonoscopy (APC). We also compared sessile serrated polyp detection rate (SSPDR), insertion times, withdrawal times, and ease of passage through the sigmoid colon. Results: EndoRings was superior to standard colonoscopy in terms of APC (1.46 vs 1.06, p=0.025) but there were no statistically significant differences in ADR or SSPDR. Mean withdrawal time (in patients with no polyps) was shorter and insertion time (all patients) was longer in the EndoRings arm by 1.8 minutes and 0.75 minutes, respectively. One provider had significantly higher detection with EndoRings and contributed substantially to the overall results. Conclusions: EndoRings can increase adenoma detection without significant increase in procedure time, but the effect varies between operators. EndoRings slows colonoscope insertion

    Rectal Indomethacin Dose Escalation (RIDE) for Prevention of Post-ERCP Pancreatitis in High-Risk Patients: a Randomized Trial

    Get PDF
    Background Although rectal indometacin 100 mg is effective in reducing the frequency and severity of pancreatitis after endoscopic retrograde cholangiopancreatography (ERCP) in high-risk patients, the optimal dose is unknown, and pancreatitis incidence remains high. The aim of this study was to compare the efficacy of two dose regimens of rectal indometacin on the frequency and severity of pancreatitis after ERCP in high-risk patients. Methods In this randomised, double-blind, comparative effectiveness trial, we enrolled patients from six tertiary medical centres in the USA. Eligible patients were those at high risk for the development of pancreatitis after ERCP. We randomly assigned eligible patients (1:1) immediately after ERCP to receive either two 50 mg indometacin suppositories and a placebo suppository (standard-dose group) or three 50 mg indometacin suppositories (high-dose group). 4 h after the procedure, patients assigned to the high-dose group received an additional 50 mg indometacin suppository, whereas patients in the standard-dose group received an additional placebo suppository. The randomisation schedule, stratified according to study centre and with no other restrictions, was computer generated by an investigator who was uninvolved in the clinical care of any participants, distributed to the sites, and kept by personnel not directly involved with the study. These same personnel were responsible for packaging the drug and placebo in opaque envelopes. Patients, study personnel, and treating physicians were masked to study group assignment. The primary outcome of the study was the development of pancreatitis after ERCP. Analyses were done on an intention-to-treat basis. This trial is registered with ClinicalTrials.gov, number NCT01912716, and enrolment is complete. Findings Between July 9, 2013, and March 22, 2018, 1037 eligible patients were enrolled and randomly assigned to receive either standard-dose (n=515) or high-dose indometacin (n=522). Pancreatitis after ERCP occurred in 141 (14%) of 1037 patients—76 (15%) of 515 patients in the standard-dose indometacin group and 65 (12%) of 522 patients in the high-dose indometacin group (risk ratio [RR] 1·19, 95% CI 0·87–1·61; p=0·32). We observed 19 adverse events that were potentially attributable to study drug. Clinically significant bleeding occurred in 14 (1%) of 1037 patients—six (1%) of 515 patients in the standard-dose indometacin group and eight (2%) of 522 patients in the high-dose indometacin group (p=0·79). Three (1%) of 522 patients in the high-dose indometacin group developed acute kidney injury versus none in the standard-dose group (p=0·25). A non-ST elevation myocardial infarction occurred in the standard-dose indometacin group 2 days after ERCP. A transient ischaemic attack occurred in the high-dose indometacin group 5 days after ERCP. All 19 adverse events, in addition to the 141 patients who developed pancreatitis after ERCP, were considered serious as all required admission to hospital. We observed no allergic reactions or deaths at 30 day follow-up. Interpretation Dose escalation to rectal indometacin 200 mg did not confer any advantage compared with the standard 100 mg regimen, with pancreatitis incidence remaining high in high-risk patients. Current practice should continue unchanged. Further research should consider the pharmacokinetics of non-steroidal anti-inflammatory drugs to determine the optimal timing of their administration to prevent pancreatitis after ERCP

    Sex differences modulating serotonergic polymorphisms implicated in the mechanistic pathways of risk for depression and related disorders:

    Full text link
    Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/137310/1/jnr23877.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/137310/2/jnr23877_am.pd
    • …
    corecore