42 research outputs found

    Vanadium based neutron beam monitor

    Get PDF
    A prototype quasiparasitic thermal neutron beam monitor based on isotropic neutron scattering from a thin natural vanadium foil and standard 3He proportional counters is conceptualized, designed, simulated, calibrated, and commissioned. The European Spallation Source designed to deliver the highest integrated neutron flux originating from a pulsed source is currently under construction in Lund, Sweden. The effort to investigate a vanadium based neutron beam monitor was triggered by a list of requirements for beam monitors permanently placed in the ESS neutron beams in order to provide reliable monitoring at complex beamlines low attenuation, linear response over a wide range of neutron fluxes, near to constant efficiency for neutron wavelengths in a range of 0.6 10 , calibration stability and the possibility to place the system in vacuum are all desirable characteristics. The scattering based prototype, employing a natural vanadium foil andstandard 3He proportional counters, was investigated at the V17 and V20 neutron beamlines of the Helmholtz Zentrum in Berlin, Germany, in several different geometrical configurations of the 3He proportional counters around the foil. Response linearity is successfully demonstrated for foil thicknesses ranging from 0.04 mm to 3.15 mm. Attenuation lower than 1 for thermal neutrons is demonstrated for the 0.04 mm and 0.125 mm foils. The geometries used for the experiment were simulated allowing for absolute flux calibration and establishing the possible range of efficiencies for various designs of the prototype. The operational flux limits for the beam monitor prototype were established as a dependency of the background radiation and prototype geometry. The herein demonstrated prototype monitors can be employed for neutron intensities ranging from 103 1010 n s

    Light-yield response of liquid scintillators using 2–6 MeV tagged neutrons

    Get PDF
    Knowledge of the neutron light-yield response is crucial to the understanding of scintillator-based neutron detectors. In this work, neutrons from 2–6MeV have been used to study the scintillation light-yield response of the liquid scintillators NE 213A, EJ 305, EJ 331 and EJ 321P using event-by-event waveform digitization. Energy calibration was performed using a GEANT4 model to locate the edge positions of the Compton distributions produced by gamma-ray sources. The simulated light yield for neutrons from a PuBe source was compared to measured recoil proton distributions, where neutron energy was selected by time-of-flight. This resulted in an energy-dependent Birks parameterization to characterize the non-linear response to the lower energy neutrons. The NE 213A and EJ 305 results agree very well with existing data and are reproduced nicely by the simulation. New results for EJ 331 and EJ 321P, where the simulation also reproduces the data well, are presented

    Response of a Li-glass/multi-anode photomultiplier detector to collimated thermal-neutron beams

    Get PDF
    The response of a position-sensitive Li-glass scintillator detector being developed for thermal-neutron detection with 6 mm position resolution has been investigated using collimated beams of thermal neutrons. The detector was moved perpendicularly through the neutron beams in 0.5 to 1.0 mm horizontal and vertical steps. Scintillation was detected in an 8 X 8 pixel multi-anode photomultiplier tube on an event-by-event basis. In general, several pixels registered large signals at each neutron-beam location. The number of pixels registering signal above a set threshold was investigated, with the maximization of the single-hit efficiency over the largest possible area of the detector as the primary goal. At a threshold of ~50% of the mean of the full-deposition peak, ~80% of the events were registered in a single pixel, resulting in an effective position resolution of ~5 mm in X and Y. Lower thresholds generally resulted in events demonstrating higher pixel multiplicities, but these events could also be localized with ~5 mm position resolution.Comment: 23 pages, 8 figure

    Co-existence of acute myeloid leukemia with multilineage dysplasia and Epstein-Barr virus-associated T-cell lymphoproliferative disorder in a patient with rheumatoid arthritis: a case report

    Get PDF
    Rheumatoid arthritis (RA) is an autoimmune disease mediated by inflammatory processes mainly at the joints. Recently, awareness of Epstein-Barr virus (EBV)-associated T-cell lymphoproliferative disorder (T-LPD) has been heightened for its association with methotraxate usage in RA patients. In the contrary, acute myeloid leukemia with multilineage dysplasia (AML-MLD) has never been documented to be present concomitantly with the above two conditions. In this report we present a case of an autopsy-proven co-existence of AML-MLD and EBV-associated T-LPD in a patient with RA

    Response of a Li-glass/multi-anode photomultiplier detector to α-particles from <sup>241</sup>Am

    Get PDF
    The response of a position-sensitive Li-glass scintillator detector to -particles from a collimated ²⁴¹Am source scanned across the face of the detector has been measured. Scintillation light was read out by an 8 x 8 pixel multi-anode photomultiplier and the signal amplitude for each pixel has been recorded for every position on a scan. The pixel signal is strongly dependent on position and in general several pixels will register a signal (a hit) above a given threshold. The effect of this threshold on hit multiplicity is studied, with a view to optimize the single-hit efficiency of the detector

    Trisomy 19 as the sole chromosomal abnormality in proliferative chronic myelomonocytic leukemia

    No full text
    Distinct morphologic and clinical features associated with specific chromosomal abnormalities have been described in subgroups of myelodysplastic syndromes (MDS), which often are losses or gains and only rarely translocations. Among 103 consecutive MDS patients diagnosed and karyotyped at the Albert-Ludwigs University of Freiburg (ALU) between 1993 and 1999, two chronic myelomonocytic leukemias (CMMoL) displayed trisomy 19 (+19) as the sole chromosomal abnormality. Three further CMMoL cases with +19 as the single abnormality, two of which previously reported, were collected from other centers. Four of the five patients presented with leukocytosis and splenomegaly, and an increased number of ringed sideroblasts was observed in two cases. Treatment was low-dose Decitabine (cases 1 and 2), oral steroids (case 3), hydroxyurea (case 4), and daunorubicin/Ara-C (case 5). Transformation to acute myeloid leukemias (AML) occurred in three/five patients (cases 1, 2, and 4) 26, 12, and 22 months after diagnosis of CMMoL, respectively. We conclude that +19 as the sole anomaly is a rare but recurrent change in CMMoL, in particular of the proliferative type. It is at present unclear which gene(s) located on chromosome 19 might have a functional role for the development of this phenotype

    A compact accelerator driven neutron source at the Applied Nuclear Physics Laboratory, Lund University

    No full text
    The Applied Nuclear Physics Group at Lund University has constructed a CANS (Compact Accelerator-driven Neutron Source). The CANS is based around a 3 MV, single-ended, Pelletron accelerator, which is used to impinge a 2.8 MeV deuterium beam into a beryllium target. The anticipated neutron production will be on the order of 10(10) n/s in 4 pi sr, with future upgrades expected to increase neutron production to 10(11) n/s. Neutron energy will be up to 9 MeV with peak emission at similar to 5 MeV. Shielding and moderation will be provided by a large water tank surrounding the target, with exit ports to allow moderated neutrons to be directed to experiments. The thermal-neutron flux at the exit of the extraction ports is anticipated to be up to 10(6) n/cm(2)/s. The CANS will be used to forward the activities of the group in the area of neutron-activation analysis, in addition to a broader range of neutron related applications

    Are occupational, hobby, or lifestyle exposures associated with Philadelphia chromosome positive chronic myeloid leukaemia?

    No full text
    OBJECTIVES—To investigate a broad range of occupational, hobby, and lifestyle exposures, suggested as risk factors for Philadelphia chromosome positive (Ph+) chronic myeloid leukaemia (CML).
METHODS—A case-control study, comprising 255 Ph+CML patients from southern Sweden and matched controls, was conducted. Individual data on work tasks, hobbies, and lifestyle exposures were obtained by telephone interviews. Occupational hygienists assessed occupational and hobby exposures for each subject individually. Also, occupational titles were obtained from national registries, and group level exposure—that is, the exposure proportion for each occupational title—was assessed with a job exposure matrix. The effects of 11 exposures using individual data and two exposures using group data (organic solvents and animal dust) were estimated.
RESULTS—For the individual data on organic solvents, an effect was found for moderate or high intensity of exposure (odds ratio (OR) 3.4, 95% confidence interval (95% CI) 1.1 to 11) and for long duration (15-20 years) of exposure (OR 2.1, 95% CI 1.1 to 4.0). By contrast, the group data showed no association (OR 0.69, 95% CI 0.27 to 1.8; moderate or high intensity versus no exposure). For extremely low frequency electromagnetic fields (EMFs), only individual data were available. An association with long occupational exposure to EMFs was found (OR 2.3, 95% CI 1.2 to 4.5). However, no effect of EMF intensity was indicated. No significant effects of benzene, gasoline or diesel, or tobacco smoking were found. OR estimates below unity were suggested for personal use of hair dye and for agricultural exposures.
CONCLUSIONS—Associations between exposure to organic solvents and EMFs, and Ph+CML were indicated but were not entirely consistent.


Keywords: risk factors; epidemiology; case-control stud
    corecore