37 research outputs found

    Vascular access approach for structural heart procedures

    Full text link
    Vascular access is an essential part of all interventional procedures whether coronary or structural. Over the last 15 to 20 years, in coronary interventions, traditional femoral access has been mostly replaced by the radial approach. Nonetheless, the femoral approach through both artery and vein is still the main approach for structural heart procedures. Over the last few years, femoral access has evolved from a puncture guided by anatomical references to more accurate ultrasound-guided approaches. The relatively recent introduction of interventions such as transcatheter aortic valve replacement has conditioned the use of large introducers and ultimately the need for specific hemostatic systems, above all, percutaneous closure devices. This manuscript reviews different anatomical concepts, puncture techniques, diagnostic assessments, and closure strategies of the main arterial and venous approaches for the diagnosis and treatment of different structural heart procedures

    Percutaneous Closure of Paravalvular Leaks: A Systematic Review

    Get PDF
    [EN] Paravalvular leak (PVL) is an uncommon yet serious complication associated with the implantation of mechanical or bioprosthetic surgical valves and more recently recognized with transcatheter aortic valves implantation (TAVI). A significant number of patients will present with symptoms of congestive heart failure or haemolytic anaemia due to PVL and need further surgical or percutaneous treatment. Until recently, surgery has been the only available therapy for the treatment of clinically significant PVLs despite the significant morbidity and mortality associated with re-operation. Percutaneous treatment of PVLs has emerged as a safe and less invasive alternative, with low complication rates and high technical and clinical success rates. However, it is a complex procedure, which needs to be performed by an experienced team of interventional cardiologists and echocardiographers. This review discusses the current understanding of PVLs, including the utility of imaging techniques in PVL diagnosis and treatment, and the principles, outcomes and complications of transcatheter therapy of PVLs. (J Interven Cardiol 2016;29:382–392

    Regional differences in STEMI care in Spain. Data from the ACI-SEC Infarction Code Registry

    Get PDF
    Introduction and objectives: Geographical and organizational differences between different autonomous communities (AC) can generate differences in care for ST-segment elevation myocardial infarction (STEMI). A total of 17 heart attack code programs have been compared in terms of incidence rate, clinical characteristics, reperfusion therapy, delay to reperfusion, and 30-day mortality. Methods: National prospective observational study (83 centers included in 17 infarction networks). The recruitment period was 3 months (April 1 to June 30, 2019) with clinical follow-up at 30 days. Results: 4366 patients with STEMI were included. The incidence rate was variable between different AC (P <.0001), as was gender (P =.003) and the prevalence of cardiovascular risk factors (P <.0001). Reperfusion treatment was primary angioplasty (range 77.5%-97.8%), fibrinolysis ( range 0%-12.9%) or no treatment (range 2.2%- 13.5%). The analysis of the delay to reperfusion showed significant differences (P <.001) for all the intervals analyzed. There were significant differences in 30-days mortality that disappeared after adjusting for clinical and healthcare network characteristics. Conclusions: Large differences in STEMI care have been detected between the different AC, in terms of incidence rate, clinical characteristics, reperfusion treatment, delay until reperfusion, and 30-day mortality. The differences in mortality disappeared after adjusting for the characteristics of the patient and the care network

    Sildenafil for improving outcomes in patients with corrected valvular heart disease and persistent pulmonary hypertension: a multicenter, double-blind, randomized clinical trial

    Get PDF
    Randomized controlled trial[Abstract] Aims: We aimed to determine whether treatment with sildenafil improves outcomes of patients with persistent pulmonary hypertension (PH) after correction of valvular heart disease (VHD). Methods and results: The sildenafil for improving outcomes after valvular correction (SIOVAC) study was a multricentric, randomized, parallel, and placebo-controlled trial that enrolled stable adults with mean pulmonary artery pressure ≥ 30 mmHg who had undergone a successful valve replacement or repair procedure at least 1 year before inclusion. We assigned 200 patients to receive sildenafil (40 mg three times daily, n = 104) or placebo (n = 96) for 6 months. The primary endpoint was the composite clinical score combining death, hospital admission for heart failure (HF), change in functional class, and patient global self-assessment. Only 27 patients receiving sildenafil improved their composite clinical score, as compared with 44 patients receiving placebo; in contrast 33 patients in the sildenafil group worsened their composite score, as compared with 14 in the placebo group [odds ratio 0.39; 95% confidence interval (CI) 0.22-0.67; P < 0.001]. The Kaplan-Meier estimates for survival without admission due to HF were 0.76 and 0.86 in the sildenafil and placebo groups, respectively (hazard ratio 2.0, 95% CI = 1.0-4.0; log-rank P = 0.044). Changes in 6-min walk test distance, natriuretic peptides, and Doppler-derived systolic pulmonary pressure were similar in both groups. Conclusion: Treatment with sildenafil in patients with persistent PH after successfully corrected VHD is associated to worse clinical outcomes than placebo. Off-label usage of sildenafil for treating this source of left heart disease PH should be avoided.This study was supported by the Instituto de Salud Carlos III, Ministerio de Economía y Competitividad, Spain, and the EU –European Regional Development Fund (EC07/90772) as well as by the Red de Investigación Cardiovascular and CIBERCV.Instituto de Salud Carlos III; EC07/9077

    Persistent Pulmonary Hypertension in Corrected Valvular Heart Disease: Hemodynamic Insights and Long-Term Survival.

    Get PDF
    Background The determinants and consequences of pulmonary hypertension after successfully corrected valvular heart disease remain poorly understood. We aim to clarify the hemodynamic bases and risk factors for mortality in patients with this condition. Methods and Results We analyzed long-term follow-up data of 222 patients with pulmonary hypertension and valvular heart disease successfully corrected at least 1 year before enrollment who had undergone comprehensive hemodynamic and imaging characterization as per the SIOVAC (Sildenafil for Improving Outcomes After Valvular Correction) clinical trial. Median (interquartile range) mean pulmonary pressure was 37 mm Hg (32-44 mm Hg) and pulmonary artery wedge pressure was 23 mm Hg (18-26 mm Hg). Most patients were classified either as having combined precapillary and postcapillary or isolated postcapillary pulmonary hypertension. After a median follow-up of 4.5 years, 91 deaths accounted for 4.21 higher-than-expected mortality in the age-matched population. Risk factors for mortality were male sex, older age, diabetes mellitus, World Health Organization functional class III and higher pulmonary vascular resistance-either measured by catheterization or approximated from ultrasound data. Higher pulmonary vascular resistance was related to diabetes mellitus and smaller residual aortic and mitral valve areas. In turn, the latter correlated with prosthetic nominal size. Six-month changes in the composite clinical score and in the 6-minute walk test distance were related to survival. Conclusions Persistent valvular heart disease-pulmonary hypertension is an ominous disease that is almost universally associated with elevated pulmonary artery wedge pressure. Pulmonary vascular resistance is a major determinant of mortality in this condition and is related to diabetes mellitus and the residual effective area of the corrected valve. These findings have important implications for individualizing valve correction procedures. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT00862043.This study was funded by the Instituto de Salud Carlos III, Ministerio de Ciencia e Innovación, Spain, the European Union–European Regional Development Fund (EC07/90772 and PI19/00649), and the Consorcio de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV).S

    Patterns of Change in Dietary Habits and Physical Activity during Lockdown in Spain Due to the COVID-19 Pandemic

    Get PDF
    Background: Lockdown due to COVID-19 influenced food habits and lifestyles with potential negative health impact. This study aims to identify patterns of change in eating habits and physical activity during COVID-19 lockdown in Spain and to identify associations with sociodemographic factors and usual habits. Methods: This cross-sectional study included 1155 adults recruited online to answer a 10-section questionnaire. The protocol assessed usual diet by means of a semi-quantitative food frequency questionnaire, usual physical activity (PA) and supplement use, dietary changes, sedentary time, PA, exposure to sunlight, sleep quality, and smoking during confinement. Patterns of dietary change were identified by factor analysis. Factor scores were included in cluster analysis together with change in PA. Results: Six patterns of dietary change were identified that together with PA changes during lockdown defined three clusters of lifestyle change: a cluster less active, a more active cluster, and a third cluster as active as usual. People who were usually less active were more likely to be classified in the cluster that increased physical activity in confinement. Scores of the Healthy Mediterranean-Style dietary pattern were higher in this group. Conclusions: Different patterns of change in lifestyles in confinement suggest the need to tailor support and advice to different population groups.This research received no external funding. J.A.T. was funded by Instituto de Salud Carlos III through the Fondo de Investigacion para la Salud (CIBEROBN CB12/03/30038) which was co-funded by the European Regional Development Fund

    Radiation and Dust Sensor for Mars Environmental Dynamic Analyzer Onboard M2020 Rover

    Get PDF
    32 pags., 26 figs., 3 tabs. -- This article belongs to the Section Remote SensorsThe Radiation and Dust Sensor is one of six sensors of the Mars Environmental Dynamics Analyzer onboard the Perseverance rover from the Mars 2020 NASA mission. Its primary goal is to characterize the airbone dust in the Mars atmosphere, inferring its concentration, shape and optical properties. Thanks to its geometry, the sensor will be capable of studying dust-lifting processes with a high temporal resolution and high spatial coverage. Thanks to its multiwavelength design, it will characterize the solar spectrum from Mars' surface. The present work describes the sensor design from the scientific and technical requirements, the qualification processes to demonstrate its endurance on Mars' surface, the calibration activities to demonstrate its performance, and its validation campaign in a representative Mars analog. As a result of this process, we obtained a very compact sensor, fully digital, with a mass below 1 kg and exceptional power consumption and data budget features.This work has been funded with the help of the Spanish National Research, Development and Innovation Program, through the grants RTI2018-099825-B-C31, ESP2016-80320-C2-1-R and ESP2014-54256-C4-3-R. DT acknowledges the financial support from the Comunidad de Madrid for an “Atracción de Talento Investigador” grant (2018-T2/TIC10500). ASL is supported by Grant PID2019-109467GB-I00 funded by MCIN/AEI/10.13039/501100011033/ and by Grupos Gobierno Vasco IT1366-19. The US co-authors performed their work under sponsorship from NASA’s Mars 2020 project, from the Game Changing Development program within the Space Technology Mission Directorate, and from the Human Exploration and Operations Directorate.Peer reviewe

    The Mars Environmental Dynamics Analyzer, MEDA. A Suite of Environmental Sensors for the Mars 2020 Mission

    Get PDF
    86 pags., 49 figs., 24 tabs.NASA’s Mars 2020 (M2020) rover mission includes a suite of sensors to monitor current environmental conditions near the surface of Mars and to constrain bulk aerosol properties from changes in atmospheric radiation at the surface. The Mars Environmental Dynamics Analyzer (MEDA) consists of a set of meteorological sensors including wind sensor, a barometer, a relative humidity sensor, a set of 5 thermocouples to measure atmospheric temperature at ∼1.5 m and ∼0.5 m above the surface, a set of thermopiles to characterize the thermal IR brightness temperatures of the surface and the lower atmosphere. MEDA adds a radiation and dust sensor to monitor the optical atmospheric properties that can be used to infer bulk aerosol physical properties such as particle size distribution, non-sphericity, and concentration. The MEDA package and its scientific purpose are described in this document as well as how it responded to the calibration tests and how it helps prepare for the human exploration of Mars. A comparison is also presented to previous environmental monitoring payloads landed on Mars on the Viking, Pathfinder, Phoenix, MSL, and InSight spacecraft.This work has been funded by the Spanish Ministry of Economy and Competitiveness, through the projects No. ESP2014-54256-C4-1-R (also -2-R, -3-R and -4-R) and AYA2015-65041-P; Ministry of Science, Innovation and Universities, projects No. ESP2016-79612-C3-1-R (also -2-R and -3-R), ESP2016-80320-C2-1-R, RTI2018-098728-B-C31 (also -C32 and -C33) and RTI2018-099825-B-C31; Instituto Nacional de Técnica Aeroespacial; Ministry of Science and Innovation’s Centre for the Development of Industrial Technology; Grupos Gobierno Vasco IT1366-19; and European Research Council Consolidator Grant no 818602. The US co-authors performed their work under sponsorship from NASA’s Mars 2020 project, from the Game Changing Development program within the Space Technology Mission Directorate and from the Human Exploration and Operations Directorate

    Outpatient Parenteral Antibiotic Treatment vs Hospitalization for Infective Endocarditis: Validation of the OPAT-GAMES Criteria

    Get PDF

    The Mars Environmental Dynamics Analyzer, MEDA. A Suite of Environmental Sensors for the Mars 2020 Mission

    Get PDF
    86 pags, 49 figs, 24 tabsNASA's Mars 2020 (M2020) rover mission includes a suite of sensors to monitor current environmental conditions near the surface of Mars and to constrain bulk aerosol properties from changes in atmospheric radiation at the surface. The Mars Environmental Dynamics Analyzer (MEDA) consists of a set of meteorological sensors including wind sensor, a barometer, a relative humidity sensor, a set of 5 thermocouples to measure atmospheric temperature at ∼1.5 m and ∼0.5 m above the surface, a set of thermopiles to characterize the thermal IR brightness temperatures of the surface and the lower atmosphere. MEDA adds a radiation and dust sensor to monitor the optical atmospheric properties that can be used to infer bulk aerosol physical properties such as particle size distribution, non-sphericity, and concentration. The MEDA package and its scientific purpose are described in this document as well as how it responded to the calibration tests and how it helps prepare for the human exploration of Mars. A comparison is also presented to previous environmental monitoring payloads landed on Mars on the Viking, Pathfinder, Phoenix, MSL, and InSight spacecraft.This work has been funded by the Spanish Ministry of Economy and Competitiveness, through the projects No. ESP2014-54256-C4-1-R (also -2-R, -3-R and -4-R) and AYA2015-65041-P; Ministry of Science, Innovation and Universities, projects No. ESP2016-79612-C3-1-R (also -2-R and -3-R), ESP2016-80320-C2-1-R, RTI2018-098728-B-C31 (also -C32 and -C33) and RTI2018-099825-B-C31; Instituto Nacional de Tecnica Aeroespacial; Ministry of Science and Innovation's Centre for the Development of Industrial Technology; Grupos Gobierno Vasco IT1366-19; and European Research Council Consolidator Grant no 818602.Peer reviewe
    corecore