95 research outputs found

    Evaluation of Early Microstructural Changes in the R6/1 Mouse Model of Huntington's Disease by Ultra-High Field Diffusion MR Imaging

    Get PDF
    Diffusion MRI (dMRI) has been able to detect early structural changes related to neurological symptoms present in Huntington's disease (HD). However, there is still a knowledge gap to interpret the biological significance at early neuropathological stages. The purpose of this study is two-fold: (i) establish if the combination of Ultra-High Field Diffusion MRI (UHFD-MRI) techniques can add a more comprehensive analysis of the early microstructural changes observed in HD, and (ii) evaluate if early changes in dMRI microstructural parameters can be linked to cellular biomarkers of neuroinflammation. Ultra-high field magnet (16.7T), diffusion tensor imaging (DTI), and neurite orientation dispersion and density imaging (NODDI) techniques were applied to fixed ex-vivo brains of a preclinical model of HD (R6/1 mice). Fractional anisotropy (FA) was decreased in deep and superficial grey matter (GM) as well as white matter (WM) brain regions with well-known early HD microstructure and connectivity pathology. NODDI parameters associated with the intracellular and extracellular compartment, such as intracellular ventricular fraction (ICVF), orientation dispersion index (ODI), and isotropic volume fractions (IsoVF) were altered in R6/1 mice GM. Further, histological studies in these areas showed that glia cell markers associated with neuroinflammation (GFAP & Iba1) were consistent with the dMRI findings. dMRI can be used to extract non-invasive information of neuropathological events present in the early stages of HD. The combination of multiple imaging techniques represents a better approach to understand the neuropathological process allowing the early diagnosis and neuromonitoring of patients affected by HD.Fil: Segatto, Rodolfo Guillermo. University Of Illinois. Deparment Of Biological Science; Estados UnidosFil: Weissmann, Carina. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Fisiología, Biología Molecular y Neurociencias. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de Fisiología, Biología Molecular y Neurociencias; ArgentinaFil: Amin, Manish. University of Florida. Department of Microbiology and Cell Science; Estados UnidosFil: Angeles López, Quetzalli D.. Consejo Nacional de Ciencia y Tecnologia de Mexico. Centro de Investigacion Cientifica y de Educacion Superior de Ensenada Baja California.; MéxicoFil: García Lara, Lucia. Consejo Nacional de Ciencia y Tecnologia de Mexico. Centro de Investigacion Cientifica y de Educacion Superior de Ensenada Baja California.; MéxicoFil: Salinas Castellanos, Libia Catalina. Consejo Nacional de Ciencia y Tecnologia de Mexico. Centro de Investigacion Cientifica y de Educacion Superior de Ensenada Baja California.; MéxicoFil: Deyoung, Daniel. University of Florida. Department of Microbiology and Cell Science; Estados UnidosFil: Segovia, Jose Manuel. Consejo Nacional de Ciencia y Tecnologia de Mexico. Centro de Investigacion Cientifica y de Educacion Superior de Ensenada Baja California.; MéxicoFil: Mareci, Thomas H.. University of Florida. Department of Microbiology and Cell Science; Estados UnidosFil: Uchitel, Osvaldo Daniel. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Fisiología, Biología Molecular y Neurociencias. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de Fisiología, Biología Molecular y Neurociencias; ArgentinaFil: Magin, Richard L.. University Of Illinois. Deparment Of Biological Science; Estados Unido

    Corrosion behaviour of new quaternary ZrNbTiAl alloys in simulated physiological solution using electrochemical techniques and surface analysis methods

    Get PDF
    The potential biomedical application of three new quaternary Zr alloys, namely Zr6Ti15Nb4Al, Zr32Ti15Nb4Al, and Zr49Ti15Nb4Al, was evaluated in vitro using electrochemical methods complemented with surface analysis of corrosion resistance. Cyclic potentiodynamic polarization (CCP) and electrochemical impedance spectroscopy (EIS) tests were performed in Ringer’s solution at 37 ºC. The electrochemical behavior of the ZrTiNbAl quaternary alloys was consistent with the formation of passivating oxide films on the surfaces of these materials. Localized breakdown of the oxide layer occurred on Zr6Ti15Nb4Al and Zr32Ti15Nb4Al alloys subjected to positive anodic polarization, a feature confirmed by scanning electron microscopy (SEM) on retrieved samples. The Zr49Ti15Nb4Al alloy, which had the highest titanium (49 wt.%) content, exhibited a larger passive range in the polarization curve and was immune to localized corrosion breakdown in a simulated physiological solution for the range of polarizations that can occur in the human bod

    Corrosion resistance of ZrTi alloys with hydroxyapatite-zirconia silver layer in simulated physiological solution containing proteins for biomaterial applications

    Get PDF
    The degradation characteristics of hydroxyapatite-zirconia-silver films (HA-ZrO2-Ag) coatings on three ZrTi alloys were investigated in Ringer’s solution containing 10% human albumin protein at 37 °C. Samples were immersed for 7 days while monitored by electrochemical impedance spectroscopy (EIS) and linear potentiodynamic polarization (LPP). The electrochemical analysis in combination with surface analytical characterization by scanning electron microscopy (SEM/EDX) reveals the stability and corrosion resistance of the HA–ZrO2-Ag coated ZrTi alloys. The characteristic feature that describes the electrochemical behaviour of the coated alloys is the coexistence of large areas of the coating presenting pores in which the ZrTi alloy substrate is exposed to the simulated physiological environment. The EIS interpretation of results was thus performed using a two-layer model of the surface film. The blocking effect in the presence the human albumin protein produces an enhancement of the corrosion resistance. The results disclose that the Zr45Ti alloy is a promising material for biomedical devices, since electrochemical stability is directly associated to biocompatibilit

    Effect of acidic fluoride solution on the corrosion resistance of ZrTi alloys for dental implant application

    Get PDF
    The electrochemical behavior of Zr5Ti, Zr25Ti, and Zr45Ti, with and without surface modification were monitored in acidic artificial saliva (pH = 3) containing NaF concentrations 0.2, 0.5, and 1 wt.%, simulating the fluoride concentrations in dental rinses. A passive behaviour for thermally oxidized ZrTi alloys was found using EIS, and XPS data show that the protective oxide film contains both TiO2 and ZrO2, though titanium contents in the outer layer bigger than those in the base alloy result from thermal oxidation. High corrosion resistance to acidic fluoridated environments of ZrTi alloys treated using thermal oxidation in air at 500 ºC

    Corrosion behaviour of porous Ti intended for biomedical applications

    Get PDF
    Porous Ti implants are being developed inorder to reduce the biomechanical mismatch between theimplant and the bone, as well as increasing the osseointegrationby improving the bone in-growth. Most of the focusin the literature has been on the structural, biological andmechanical characterization of porous Ti whereas there islimited information on the electrochemical characterization.Therefore, the present work aims to study the corrosionbehaviour of porous Ti having 30 and 50 % ofnominal porosity, produced by powder metallurgy routeusing the space holder technique. The percentage, size anddistribution of the pores were determined by image analysis.Electrochemical tests consisting of potentiodynamicpolarization and electrochemical impedance spectroscopywere performed in 9 g/L NaCl solution at body temperature.Electrochemical studies revealed that samples presenteda less stable oxide film at increased porosity, morespecifically, the complex geometry and the interconnectivityof the pores resulted in formation of less protectiveoxide film in the pores.This study was supported by FCT with the reference project UID/EEA/04436/2013, by FEDER funds through the COMPETE 2020 – Programa Operacional Competitividade e Internacionalizac¸a˜o (POCI) with the reference project POCI-01-0145- FEDER-006941, Programa de Acc¸o˜es Universita´rias Integradas LusoFrancesas’ (PAUILF TC-12_14), and The Calouste Gulbenkian Foundation through ‘‘Programa de Mobilidade Acade´mica para Professores’’. The authors would also like to acknowledge Prof. Ana Senos (University of Aveiro) and Prof. Jose´ Carlos Teixeira (University of Minho) for the provision of the characterization facilities.info:eu-repo/semantics/publishedVersio

    Stability of Some Copper-based Dental Materials in Artificial Saliva

    No full text

    Electrochemical aspects of Ti-Ta alloys in HBSS

    No full text
    International audienc
    corecore