    Geomagnetically Induced Currents and Harmonic Distortion: High time Resolution Case Studies

    Get PDF
    High time resolution (1‐5 s) magnetometer, geomagnetically induced current (GIC), and mains harmonic distortion data from the Halfway Bush substation in Dunedin, New Zealand are analyzed. A recently developed technique using VLF radio wave data provides high resolution measurements of mains harmonic distortion levels. Three case studies are investigated, each involving high rates of change of local geomagnetic field, but with different timescales of magnetospheric driver mechanisms, and different substation transformer configurations. Two cases of enhanced GIC during substorm events are analyzed, and one case of a storm sudden commencement. Time delays between magnetic field fluctuations and induced transformer currents are found to be ~100 s for substorm events, but only ~20 s for the storm sudden commencement containing higher frequency variations. Boxcar averaging of the magnetic field fluctuations using running windows of ± 2 minutes leads to spectral power profiles similar to those of GIC profiles, with reduced power at frequencies >0.003 Hz (periods 5 minutes). This low frequency component of the magnetic field power spectrum appears necessary for mains harmonic distortion to occur

    Long-lasting geomagnetically induced currents and harmonic distortion observed in New Zealand during the 07-08 September 2017 Disturbed Period

    Get PDF
    Several periods of Geomagnetically Induced Currents (GIC) were detected in the Halfway Bush substation in Dunedin, South Island, New Zealand, as a result of intense geomagnetic storm activity during 06 to 09 September 2017. Unprecedented data coverage from a unique combination of instrumentation is analyzed, i.e., measurements of GIC on the single phase bank transformer T4 located within the substation, nearby magnetic field perturbation measurements, very low frequency (VLF) wideband measurements detecting the presence of power system harmonics, and high‐voltage harmonic distortion measurements. Two solar wind shocks occurred within 25 hours, generating four distinct periods of GIC. Two of the GIC events were associated with the arrival of the shocks themselves. These generated large but short‐lived GIC effects that resulted in no observable harmonic generation. Nearby and more distant magnetometers showed good agreement in measuring these global‐scale magnetic field perturbations. However, two subsequent longer‐lasting GIC periods, up to 30 minutes in duration, generated harmonics detected by the VLF receiver systems, when GIC levels continuously exceeded 15 A in T4. Nearby and more distant magnetometers showed differences in their measurements of the magnetic field perturbations at these times, suggesting the influence of small‐scale ionospheric current structures close to Dunedin. VLF receiver systems picked up harmonics from the substation, up to the 30th harmonic, consistent with observed high‐voltage increases in even harmonic distortion, along with small decreases in odd harmonic distortion

    Long-term geomagnetically induced current observations in New Zealand: Earth return corrections and geomagnetic field driver

    Get PDF
    Transpower New Zealand Limited has measured DC currents in transformer neutrals in the New Zealand electrical network at multiple South Island locations. Near-continuous archived DC current data exist since 2001, starting with 12 different substations and expanding from 2009 to include 17 substations. From 2001 to 2015 up to 58 individual transformers were simultaneously monitored. Primarily, the measurements were intended to monitor the impact of the high-voltage DC system linking the North and South Islands when it is operating in “Earth return” mode. However, after correcting for Earth return operation, as described here, the New Zealand measurements provide an unusually long and spatially detailed set of geomagnetically induced current (GIC) measurements. We examine the peak GIC magnitudes observed from these observations during two large geomagnetic storms on 6 November 2001 and 2 October 2013. Currents of ~30–50 A are observed, depending on the measurement location. There are large spatial variations in the GIC observations over comparatively small distances, which likely depend upon network layout and ground conductivity. We then go on to examine the GIC in transformers throughout the South Island during more than 151 h of geomagnetic storm conditions. We compare the GIC to the various magnitude and rate of change components of the magnetic field. Our results show that there is a strong correlation between the magnitude of the GIC and the rate of change of the horizontal magnetic field (H′). This correlation is particularly clear for transformers that show large GIC current during magnetic storms

    An inter-country comparison of unofficial payments: results of a health sector social audit in the Baltic States

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Cross-country comparisons of unofficial payments in the health sector are sparse. In 2002 we conducted a social audit of the health sector of the three Baltic States.</p> <p>Methods</p> <p>Some 10,320 household interviews from a stratified, last-stage-random, sample of 30 clusters per country, together with institutional reviews, produced preliminary results. Separate focus groups of service users, nurses and doctors interpreted these findings. Stakeholder workshops in each country discussed the survey and focus group results.</p> <p>Results</p> <p>Nearly one half of the respondents did not consider unofficial payments to health workers to be corruption, yet one half (Estonia 43%, Latvia 45%, Lithuania 64%) thought the level of corruption in government health services was high. Very few (Estonia 1%, Latvia 3%, Lithuania 8%) admitted to making unofficial payments in their last contact with the services. Around 14% of household members across the three countries gave gifts in their last contact with government services.</p> <p>Conclusion</p> <p>This social audit allowed comparison of perceptions, attitudes and experience regarding unofficial payments in the health services of the three Baltic States. Estonia showed least corruption. Latvia was in the middle. Lithuania evidenced the most unofficial payments, the greatest mistrust towards the system. These findings can serve as a baseline for interventions, and to compare each country's approach to health service reform in relation to unofficial payments.</p

    Association of Rare and Common Variation in the Lipoprotein Lipase Gene With Coronary Artery Disease.

    Get PDF
    IMPORTANCE: The activity of lipoprotein lipase (LPL) is the rate-determining step in clearing triglyceride-rich lipoproteins from the circulation. Mutations that damage the LPL gene (LPL) lead to lifelong deficiency in enzymatic activity and can provide insight into the relationship of LPL to human disease. OBJECTIVE: To determine whether rare and/or common variants in LPL are associated with early-onset coronary artery disease (CAD). DESIGN, SETTING, AND PARTICIPANTS: In a cross-sectional study, LPL was sequenced in 10 CAD case-control cohorts of the multinational Myocardial Infarction Genetics Consortium and a nested CAD case-control cohort of the Geisinger Health System DiscovEHR cohort between 2010 and 2015. Common variants were genotyped in up to 305 699 individuals of the Global Lipids Genetics Consortium and up to 120 600 individuals of the CARDIoGRAM Exome Consortium between 2012 and 2014. Study-specific estimates were pooled via meta-analysis. EXPOSURES: Rare damaging mutations in LPL included loss-of-function variants and missense variants annotated as pathogenic in a human genetics database or predicted to be damaging by computer prediction algorithms trained to identify mutations that impair protein function. Common variants in the LPL gene region included those independently associated with circulating triglyceride levels. MAIN OUTCOMES AND MEASURES: Circulating lipid levels and CAD. RESULTS: Among 46 891 individuals with LPL gene sequencing data available, the mean (SD) age was 50 (12.6) years and 51% were female. A total of 188 participants (0.40%; 95% CI, 0.35%-0.46%) carried a damaging mutation in LPL, including 105 of 32 646 control participants (0.32%) and 83 of 14 245 participants with early-onset CAD (0.58%). Compared with 46 703 noncarriers, the 188 heterozygous carriers of an LPL damaging mutation displayed higher plasma triglyceride levels (19.6 mg/dL; 95% CI, 4.6-34.6 mg/dL) and higher odds of CAD (odds ratio = 1.84; 95% CI, 1.35-2.51; P < .001). An analysis of 6 common LPL variants resulted in an odds ratio for CAD of 1.51 (95% CI, 1.39-1.64; P = 1.1 × 10-22) per 1-SD increase in triglycerides. CONCLUSIONS AND RELEVANCE: The presence of rare damaging mutations in LPL was significantly associated with higher triglyceride levels and presence of coronary artery disease. However, further research is needed to assess whether there are causal mechanisms by which heterozygous lipoprotein lipase deficiency could lead to coronary artery disease

    The Importance of Getting Names Right: The Myth of Markets for Water

    Full text link

    Protein-Truncating Variants at the Cholesteryl Ester Transfer Protein Gene and Risk for Coronary Heart Disease

    No full text
    RATIONALE: Therapies that inhibit CETP (cholesteryl ester transfer protein) have failed to demonstrate a reduction in risk for coronary heart disease (CHD). Human DNA sequence variants that truncate the CETP gene may provide insight into the efficacy of CETP inhibition. OBJECTIVE: To test whether protein-truncating variants (PTVs) at the CETP gene were associated with plasma lipid levels and CHD. METHODS AND RESULTS: We sequenced the exons of the CETP gene in 58 469 participants from 12 case-control studies (18 817 CHD cases, 39 652 CHD-free controls). We defined PTV as those that lead to a premature stop, disrupt canonical splice sites, or lead to insertions/deletions that shift frame. We also genotyped 1 Japanese-specific PTV in 27561 participants from 3 case-control studies (14 286 CHD cases, 13 275 CHD-free controls). We tested association of CETP PTV carrier status with both plasma lipids and CHD. Among 58 469 participants with CETP gene-sequencing data available, average age was 51.5 years and 43% were women; 1 in 975 participants carried a PTV at the CETP gene. Compared with noncarriers, carriers of PTV at CETP had higher high-density lipoprotein cholesterol (effect size, 22.6 mg/dL; 95% confidence interval, 18-27; P<1.0×10-4), lower low-density lipoprotein cholesterol (-12.2 mg/dL; 95% confidence interval, -23 to -0.98; P=0.033), and lower triglycerides (-6.3%; 95% confidence interval, -12 to -0.22; P=0.043). CETP PTV carrier status was associated with reduced risk for CHD (summary odds ratio, 0.70; 95% confidence interval, 0.54-0.90; P=5.1×10-3). CONCLUSIONS: Compared with noncarriers, carriers of PTV at CETP displayed higher high-density lipoprotein cholesterol, lower low-density lipoprotein cholesterol, lower triglycerides, and lower risk for CHD
    corecore