50 research outputs found

    Comparison Between Fully and Partially Filled Dielectric Materials on the Waveguide of Circularly Polarised Radial Line Slot Array Antennas

    Full text link
    This paper presents an investigation on the waveguide of circularly polarised radial line slot array (RLSA) antennas to improve gain and radiation bandwidth. Two circularly polarised (CP) RLSA antennas were designed with two different waveguide configurations. In the first configuration the waveguide is fully filled with dielectric materials and in the second configuration the waveguide is partially filled with dielectric materials and rest of the waveguide is filled with air. Numerical results of these two CP-RLSA antennas with two different waveguide configurations are presented and compared. Significant improvements have been made in the 3-dB directivity bandwidth and aperture efficiency of the antenna having waveguide partially filled with dielectric material. The 3-dB directivity bandwidth was measured 6.2% and aperture efficiency increased to 55.5%. The CP-RLSA antenna has also achieved a peak directivity of 31.7 dBic and a gain of 31.2 dBic as compared to the directivity 30.1 dBic and gain 29.5 dBic, respectively achieved with the CP-RLSA antenna having waveguide fully filled with dielectric material

    The global burden of cancer attributable to risk factors, 2010-19: a systematic analysis for the Global Burden of Disease Study 2019

    Get PDF

    Pooled analysis of WHO Surgical Safety Checklist use and mortality after emergency laparotomy

    Get PDF
    Background The World Health Organization (WHO) Surgical Safety Checklist has fostered safe practice for 10 years, yet its place in emergency surgery has not been assessed on a global scale. The aim of this study was to evaluate reported checklist use in emergency settings and examine the relationship with perioperative mortality in patients who had emergency laparotomy. Methods In two multinational cohort studies, adults undergoing emergency laparotomy were compared with those having elective gastrointestinal surgery. Relationships between reported checklist use and mortality were determined using multivariable logistic regression and bootstrapped simulation. Results Of 12 296 patients included from 76 countries, 4843 underwent emergency laparotomy. After adjusting for patient and disease factors, checklist use before emergency laparotomy was more common in countries with a high Human Development Index (HDI) (2455 of 2741, 89.6 per cent) compared with that in countries with a middle (753 of 1242, 60.6 per cent; odds ratio (OR) 0.17, 95 per cent c.i. 0.14 to 0.21, P <0001) or low (363 of 860, 422 per cent; OR 008, 007 to 010, P <0.001) HDI. Checklist use was less common in elective surgery than for emergency laparotomy in high-HDI countries (risk difference -94 (95 per cent c.i. -11.9 to -6.9) per cent; P <0001), but the relationship was reversed in low-HDI countries (+121 (+7.0 to +173) per cent; P <0001). In multivariable models, checklist use was associated with a lower 30-day perioperative mortality (OR 0.60, 0.50 to 073; P <0.001). The greatest absolute benefit was seen for emergency surgery in low- and middle-HDI countries. Conclusion Checklist use in emergency laparotomy was associated with a significantly lower perioperative mortality rate. Checklist use in low-HDI countries was half that in high-HDI countries.Peer reviewe

    Population-level risks of alcohol consumption by amount, geography, age, sex, and year: a systematic analysis for the Global Burden of Disease Study 2020

    Get PDF
    Background The health risks associated with moderate alcohol consumption continue to be debated. Small amounts of alcohol might lower the risk of some health outcomes but increase the risk of others, suggesting that the overall risk depends, in part, on background disease rates, which vary by region, age, sex, and year. Methods For this analysis, we constructed burden-weighted dose–response relative risk curves across 22 health outcomes to estimate the theoretical minimum risk exposure level (TMREL) and non-drinker equivalence (NDE), the consumption level at which the health risk is equivalent to that of a non-drinker, using disease rates from the Global Burden of Diseases, Injuries, and Risk Factors Study (GBD) 2020 for 21 regions, including 204 countries and territories, by 5-year age group, sex, and year for individuals aged 15–95 years and older from 1990 to 2020. Based on the NDE, we quantified the population consuming harmful amounts of alcohol. Findings The burden-weighted relative risk curves for alcohol use varied by region and age. Among individuals aged 15–39 years in 2020, the TMREL varied between 0 (95% uncertainty interval 0–0) and 0·603 (0·400–1·00) standard drinks per day, and the NDE varied between 0·002 (0–0) and 1·75 (0·698–4·30) standard drinks per day. Among individuals aged 40 years and older, the burden-weighted relative risk curve was J-shaped for all regions, with a 2020 TMREL that ranged from 0·114 (0–0·403) to 1·87 (0·500–3·30) standard drinks per day and an NDE that ranged between 0·193 (0–0·900) and 6·94 (3·40–8·30) standard drinks per day. Among individuals consuming harmful amounts of alcohol in 2020, 59·1% (54·3–65·4) were aged 15–39 years and 76·9% (73·0–81·3) were male. Interpretation There is strong evidence to support recommendations on alcohol consumption varying by age and location. Stronger interventions, particularly those tailored towards younger individuals, are needed to reduce the substantial global health loss attributable to alcohol. Funding Bill & Melinda Gates Foundation

    Global variation in anastomosis and end colostomy formation following left-sided colorectal resection

    Get PDF
    Background End colostomy rates following colorectal resection vary across institutions in high-income settings, being influenced by patient, disease, surgeon and system factors. This study aimed to assess global variation in end colostomy rates after left-sided colorectal resection. Methods This study comprised an analysis of GlobalSurg-1 and -2 international, prospective, observational cohort studies (2014, 2016), including consecutive adult patients undergoing elective or emergency left-sided colorectal resection within discrete 2-week windows. Countries were grouped into high-, middle- and low-income tertiles according to the United Nations Human Development Index (HDI). Factors associated with colostomy formation versus primary anastomosis were explored using a multilevel, multivariable logistic regression model. Results In total, 1635 patients from 242 hospitals in 57 countries undergoing left-sided colorectal resection were included: 113 (6·9 per cent) from low-HDI, 254 (15·5 per cent) from middle-HDI and 1268 (77·6 per cent) from high-HDI countries. There was a higher proportion of patients with perforated disease (57·5, 40·9 and 35·4 per cent; P < 0·001) and subsequent use of end colostomy (52·2, 24·8 and 18·9 per cent; P < 0·001) in low- compared with middle- and high-HDI settings. The association with colostomy use in low-HDI settings persisted (odds ratio (OR) 3·20, 95 per cent c.i. 1·35 to 7·57; P = 0·008) after risk adjustment for malignant disease (OR 2·34, 1·65 to 3·32; P < 0·001), emergency surgery (OR 4·08, 2·73 to 6·10; P < 0·001), time to operation at least 48 h (OR 1·99, 1·28 to 3·09; P = 0·002) and disease perforation (OR 4·00, 2·81 to 5·69; P < 0·001). Conclusion Global differences existed in the proportion of patients receiving end stomas after left-sided colorectal resection based on income, which went beyond case mix alone

    Plant growth promoting rhizobia: challenges and opportunities

    Get PDF

    Highly Efficient and Wideband Millimeter-Wave Slotted-Array Antenna Technology for 5G Communications

    Full text link
    The 5G, 6G of future wireless technology has brought a growing demand for different types of electrically small or large antennas, which are highly efficient, directive, and provide wideband coverage. We have presented here a compact and highly efficient slotted-array antenna technology operating at a millimeter-wave frequency range to be used for the emerging applications of 5G wireless backhauling and mobile radio services. The antenna consists of two conducting plates, with the upper plate having a slotted array in the form of a spiral. A waveguide forms between these plates and supports outward traveling TEM waves generated from a single coaxial connector at the center of the antenna. The slots are arrayed to generate circularly polarized electric fields. The antenna was simulated using CST Microwave Studio to validate the design mechanism. With a compact dimension of 0.1 m diameter, the proposed antenna achieved an extremely high gain of 27.2 dBic. The antenna has shown a wide 3dB gain bandwidth of 4.6 GHz, ranging from 33.2 GHz to 37.8 GHz, and an overall wide bandwidth of 13%. The antenna has demonstrated an aperture efficiency of 43%, and the total efficiency is varied between (87-93)% over the operating frequency range

    A Low-profile and Efficient Front-End Antenna for Point-to-Point Wireless Communication Links

    Full text link
    This paper investigates the design and performance of an efficient, medium-gain, front-end antenna of the type of radial line slot array (RLSA), for wireless communication systems. The antenna consists of two conducting metal plates forming a radial waveguide. The top plate is composed of six rings of radiating slots in a spiral pattern. A single coaxial connector is used to feed the electromagnetic energy from the bottom of the radial waveguide. The antenna has a radius of 0.15 m and operating at a frequency of 12 GHz. It was simulated using Computer Simulation Technology (CST) Microwave Studio 2019 and the results show that the antenna has an acceptable level of impedance matching in the frequency range from 11 GHz to 13 GHz, with a peak directivity of 25.6 dBi and a peak realized gain of 25 dBic at 12 GHz. Its radiation efficiency is 96% and a total efficiency is 85.3% at 12 GHz

    A Beam Squinted Linearly Polarised Radial Line Slot Array Antenna with Improved Return Loss Bandwidth

    Full text link
    This paper presents an investigation to improve the poor return loss performance of linearly polarised radial line slot array (RLSA) antenna. The problem was tackled by applying the beam squinting technique. The antenna consists of radiating surface with a circular cavity and supports outward-travelling electromagnetic waves. The antenna is excited via a rear mounted modified disk-ended dielectric coated SMA connector. The simulation results show that the return loss performance has improved significantly over the entire frequency band with a return loss bandwidth of 52.5%. The far-field result indicates that the antenna has achieved a peak directivity of 24.7 dBi at 17 GHz with a beam squinted angle of 18° and a side lobe level of -10 dB

    A Double Layer Circularly Polarised Radial Line Slot Array Antenna with Uniform Aperture Illumination

    Full text link
    In this paper, we have designed and investigated a double layer circularly polarised radial line slot array (RLSA) antenna for satellite communication. The antenna is composed of twofold radial waveguide with slots acting as radiating elements on its surface. The radiating slots are arranged in a spiral pattern on the antenna aperture. Every slot has a particular length and position. The slots are oriented in a way to intercept the radial currents on the upper waveguide. The slot lengths were varied to achieve a uniform aperture distribution. The electromagnetic power is fed from center of the lower waveguide. Numerical results show that the antenna is well matched within the operating frequency range. The far-field results indicate a peak directivity of 27 dBi at 20 GHz with a good pattern quality and lower side lobe level of -27.2 dB
    corecore