39 research outputs found

    Inferior Spear-like Lens Opacity as a Sign of Keratoconus

    Get PDF
    Purpose: To report 21 cases of typical inferior feather-shape lens opacity associated with keratoconus. Methods: In this cross-sectional study, we evaluated the association of keratoconus with inferior feather-shape lens opacity in refractive surgery candidates. Visual acuity, demographic, refractive, and topographic characteristics of 26 eyes of 21 patients with inferior feather-shape lens opacity were evaluated in detail. Pedigree analysis was also performed to assess possible inheritance. Results: Overall, 2122 out of 33,368 cases (6.4%) without lens opacity had keratoconus, while 20 out of 21 patients (95.2%) with peculiar lens opacity had definite keratoconus (P < 0.001). Lens opacity was bilateral in 5 cases (24%), and keratoconus was bilateral in all 20 patients with lens opacity. Nine eyes out of thirty-six with a complete data record (25%) had severe keratoconus and underwent deep lamellar keratoplasty, while 11 (31%) had forme fruste keratoconus. Pedigrees were drawn for eight patients, most families of whom suggested an X-linked recessive inheritance. Conclusion: The present study was the first to investigate patients with a peculiar inferior feather-shape lens opacity accompanied by bilateral keratoconus, which was observed in 95% of the patients. This finding should raise awareness as to the possibility of diagnosing keratoconus in the eyes of the patients with these characteristics

    Corneal Parameters in Healthy Subjects Assessed by Corvis ST

    Get PDF
    Purpose: To evaluate corneal biomechanics using Corvis ST in healthy eyes from Iranian keratorefractive surgery candidates. Methods: In this prospective consecutive observational case series, the intraocular pressure (IOP), central corneal thickness (CCT), and biomechanical properties of 1,304 eyes from 652 patients were evaluated using Corvis ST. Keratometric readings and manifest refraction were also recorded. Results: The mean (±SD) age of participants was 28 ± 5 years, and 31.7% were male. The mean spherical equivalent refraction was –3.50 ± 1.57 diopters (D), the mean IOP was 16.8 ± 2.9 mmHg, and the mean CCT was 531 ± 31 μm for the right eye. The respective means (±SD) corneal biomechanical parameters of the right eye were as follows: first applanation time: 7.36 ± 0.39 milliseconds (ms); first applanation length: 1.82 ± 0.22 mm; velocity in: 0.12 ± 0.04 m/s; second applanation time: 20.13 ± 0.48 ms; second applanation length: 1.34 ± 0.55 mm; velocity out: –0.67 ± 0.17 m/s; total time: 16.84 ± 0.64 ms; deformation amplitude: 1.05 ± 0.10 mm; peak distance: 4.60 ± 1.01 mm; and concave radius of curvature: 7.35 ± 1.39 mm. In the linear regression analysis, IOP exhibited a statistically significant association with the first and second applanation times, total time, velocity in, peak distance, deformation amplitude, and concave radius of curvature. Conclusion: Our study results can be used as a reference for the interpretation of Corvis ST parameters in healthy refractive surgery candidates in the Iranian population. Our results confirmed that IOP is a major determinant of Corvis parameters

    Phototoxic aptamers selectively enter and kill epithelial cancer cells

    Get PDF
    The majority of cancers arise from malignant epithelial cells. We report the design of synthetic oligonucleotides (aptamers) that are only internalized by epithelial cancer cells and can be precisely activated by light to kill such cells. Specifically, phototoxic DNA aptamers were selected to bind to unique short O-glycan-peptide signatures on the surface of breast, colon, lung, ovarian and pancreatic cancer cells. These surface antigens are not present on normal epithelial cells but are internalized and routed through endosomal and Golgi compartments by cancer cells, thus providing a focused mechanism for their intracellular delivery. When modified at their 5′ end with the photodynamic therapy agent chlorin e6 and delivered to epithelial cancer cells, these aptamers exhibited a remarkable enhancement (>500-fold increase) in toxicity upon light activation, compared to the drug alone and were not cytotoxic towards cell types lacking such O-glycan-peptide markers. Our findings suggest that these synthetic oligonucleotide aptamers can serve as delivery vehicles in precisely routing cytotoxic cargoes to and into epithelial cancer cells

    Association between retinal vein occlusion, axial length and vitreous chamber depth measured by optical low coherence reflectometry.

    Get PDF
    BACKGROUND: Results of ocular biometric measurements in retinal vein occlusion (RVO) eyes are still inconclusive and controversial. The aim of this study was to evaluate the association between ocular axial length (AL), vitreous chamber depth (VCD) and both central (CRVO) and branch retinal vein occlusions (BRVO) using optical low coherence reflectometry (OLCR). METHODS: Both eyes of 37 patients with unilateral CRVO (mean age: 66 +/- 14 years, male:female - 21:16) and 46 patients with unilateral BRVO (mean age: 63 +/- 12 years, male:female - 24:22) were enrolled in this study. The control group consisted of randomly selected single eyes of 67 age and gender matched volunteers without the presence or history of RVO (mean age: 64 +/- 14 years, male:female - 34:33). Optical biometry was performed by OLCR biometer (LenStar LS 900). Average keratometry readings, central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), AL and VCD of eyes with RVO were compared with those of fellow eyes using paired t-tests and with those of control eyes using independent t-tests. RESULTS: Mean CCT, ACD and LT, average keratometry readings of affected RVO eyes, unaffected fellow eyes and control eyes was not statistically different in either groups. In eyes with CRVO mean AL and VCD of affected eyes were significantly shorter than those of control eyes (p < 0.001, p < 0.05), mean difference in AL and VCD between the affected and control eyes was 0.56 +/- 0.15 mm and 0.45 +/- 0.19 mm, respectively. In eyes with BRVO, mean AL of the affected eyes was significantly shorter with a mean difference of 0.57 +/- 0.15 mm (p < 0.001) and the VCD was significantly shorter with a mean difference of 0.61 +/- 0.15 mm (p < 0.001) comparing with the control eyes. CONCLUSION: Shorter AL and VCD might be a potential anatomical predisposing factor for development either of CRVO or BRVO

    Inferior Spear-like Lens Opacity as A Sign of Keratoconus

    Full text link
    Purpose: To report 21 cases of typical inferior feather-shape lens opacity associated with keratoconus. Methods: In this cross-sectional study, we evaluated the association of keratoconus with inferior feather-shape lens opacity in refractive surgery candidates. Visual acuity, demographic, refractive, and topographic characteristics of 26 eyes of 21 patients with inferior feather-shape lens opacity were evaluated in detail. Pedigree analysis was also performed to assess possible inheritance. Results: Overall, 2122 out of 33,368 cases (6.4%) without lens opacity had keratoconus, while 20 out of 21 patients (95.2%) with peculiar lens opacity had definite keratoconus (P &lt; 0.001). Lens opacity was bilateral in 5 cases (24%), and keratoconus was bilateral in all 20 patients with lens opacity. Nine eyes out of thirty-six with a complete data record (25%) had severe keratoconus and underwent deep lamellar keratoplasty, while 11 (31%) had forme fruste keratoconus. Pedigrees were drawn for eight patients, most families of whom suggested an X-linked recessive inheritance. Conclusion: The present study was the first to investigate patients with a peculiar inferior feather-shape lens opacity accompanied by bilateral keratoconus, which was observed in 95% of the patients. This finding should raise awareness as to the possibility of diagnosing keratoconus in the eyes of the patients with these characteristics

    Natural radioactivity levels of 226Ra and 40K in soil of Zanjan province, Iran

    No full text
    Radioactivity concentration of naturally occurring radionuclides, 226Ra and 40K, in soil samples of Zanjan province, in north-west of Iran and from 21 geographical areas was measured by gamma spectrometry. The activity concentration of 226Ra ranged from 58.4±1.8 to 132±3.1 Bq kg-1 with the mean value of 88.5±22.9 Bq kg-1. The activity concentration of 40K ranged from 267±5.9 to 791±8.1 Bq kg-1 with the mean value of 497.4±162.6 Bq kg-1. The mean values for absorbed dose rate in air and annual effective dose were determined as 62.6±16.5 nGy h-1 and 0.076±0.02 mSv, respectively. © The Author 2010. Published by Oxford University Press. All rights reserved

    Corneal Parameters in Healthy Subjects Assessed by Corvis ST

    Full text link
    Purpose: To evaluate corneal biomechanics using Corvis ST in healthy eyes from Iranian keratorefractive surgery candidates. Methods: In this prospective consecutive observational case series, the intraocular pressure (IOP), central corneal thickness (CCT), and biomechanical properties of 1,304 eyes from 652 patients were evaluated using Corvis ST. Keratometric readings and manifest refraction were also recorded. Results: The mean (±SD) age of participants was 28 ± 5 years, and 31.7% were male. The mean spherical equivalent refraction was –3.50 ± 1.57 diopters (D), the mean IOP was 16.8 ± 2.9 mmHg, and the mean CCT was 531 ± 31 μm for the right eye. The respective means (±SD) corneal biomechanical parameters of the right eye were as follows: first applanation time: 7.36 ± 0.39 milliseconds (ms); first applanation length: 1.82 ± 0.22 mm; velocity in: 0.12 ± 0.04 m/s; second applanation time: 20.13 ± 0.48 ms; second applanation length: 1.34 ± 0.55 mm; velocity out: –0.67 ± 0.17 m/s; total time: 16.84 ± 0.64 ms; deformation amplitude: 1.05 ± 0.10 mm; peak distance: 4.60 ± 1.01 mm; and concave radius of curvature: 7.35 ± 1.39 mm. In the linear regression analysis, IOP exhibited a statistically significant association with the first and second applanation times, total time, velocity in, peak distance, deformation amplitude, and concave radius of curvature. Conclusion: Our study results can be used as a reference for the interpretation of Corvis ST parameters in healthy refractive surgery candidates in the Iranian population. Our results confirmed that IOP is a major determinant of Corvis parameters
    corecore