821 research outputs found
Compact in-vacuum gamma-ray spectrometer for high-repetition rate PW-class laser-matter interaction
With the advent of high repetition rate laser facilities, novel diagnostic
tools compatible with these advanced specifications are in demand. This paper
presents the design of an active gamma-ray spectrometer intended for these high
repetition rate experiments, with particular emphasis on functionality within a
PW level laser-plasma interaction chamber's extreme conditions. The
spectrometer uses stacked scintillators to accommodate a broad range of
gamma-ray energies, demonstrating its adaptability for various experimental
setups. Additionally, it has been engineered to maintain compactness,
electromagnetic pulse resistance, and ISO-5 cleanliness requirements while
ensuring high sensitivity. The paper also outlines the unfolding process, to
recover the gamma-ray spectrum from the spectrometer's captured image thanks to
a calibration using a Co source
Recommended from our members
Laser-driven acceleration of quasi-monoenergetic, near-collimated titanium ions via a transparency-enhanced acceleration scheme
Laser-driven ion acceleration has been an active research area in the past two decades with the prospects of designing novel and compact ion accelerators. Many potential applications in science and industry require high-quality, energetic ion beams with low divergence and narrow energy spread. Intense laser ion acceleration research strives to meet these challenges and may provide high charge state beams, with some successes for carbon and lighter ions. Here we demonstrate the generation of well collimated, quasi-monoenergetic titanium ions with energies ∼145 and 180 MeV in experiments using the high-contrast(<10-9) and high-intensity (6× 1020 W cm-2) Trident laser and ultra-Thin (∼100 nm) titanium foil targets. Numerical simulations show that the foils become transparent to the laser pulses, undergoing relativistically induced transparency (RIT), resulting in a two-stage acceleration process which lasts until ∼2 ps after the onset of RIT. Such long acceleration time in the self-generated electric fields in the expanding plasma enables the formation of the quasi-monoenergetic peaks. This work contributes to the better understanding of the acceleration of heavier ions in the RIT regime, towards the development of next generation laser-based ion accelerators for various applications
ART-XC: A Medium-energy X-ray Telescope System for the Spectrum-R-Gamma Mission
The ART-XC instrument is an X-ray grazing-incidence telescope system in an ABRIXAS-type optical configuration optimized for the survey observational mode of the Spectrum-RG astrophysical mission which is scheduled to be launched in 2011. ART-XC has two units, each equipped with four identical X-ray multi-shell mirror modules. The optical axes of the individual mirror modules are not parallel but are separated by several degrees to permit the four modules to share a single CCD focal plane detector, 1/4 of the area each. The 450-micron-thick pnCCD (similar to the adjacent eROSITA telescope detector) will allow detection of X-ray photons up to 15 keV. The field of view of the individual mirror module is about 18 x 18 arcminutes(exp 2) and the sensitivity of the ART-XC system for 4 years of survey will be better than 10(exp -12) erg s(exp -1) cm(exp -2) over the 4-12 keV energy band. This will allow the ART-XC instrument to discover several thousand new AGNs
Laser-Plasma Interactions Enabled by Emerging Technologies
An overview from the past and an outlook for the future of fundamental
laser-plasma interactions research enabled by emerging laser systems
Interferometry of Direct Photons in Central 280Pb+208Pb Collisions at 158A GeV
Two-particle correlations of direct photons were measured in central
208Pb+208Pb collisions at 158 AGeV. The invariant interferometric radii were
extracted for 100<K_T<300 MeV/c and compared to radii extracted from charged
pion correlations. The yield of soft direct photons, K_T<300 MeV/c, was
extracted from the correlation strength and compared to theoretical
calculations.Comment: 5 pages, 4 figure
Feasibility studies of the time-like proton electromagnetic form factor measurements with PANDA at FAIR
The possibility of measuring the proton electromagnetic form factors in the
time-like region at FAIR with the \PANDA detector is discussed. Detailed
simulations on signal efficiency for the annihilation of into a
lepton pair as well as for the most important background channels have been
performed. It is shown that precision measurements of the differential cross
section of the reaction can be obtained in a wide
angular and kinematical range. The individual determination of the moduli of
the electric and magnetic proton form factors will be possible up to a value of
momentum transfer squared of (GeV/c). The total cross section will be measured up to (GeV/c).
The results obtained from simulated events are compared to the existing data.
Sensitivity to the two photons exchange mechanism is also investigated.Comment: 12 pages, 4 tables, 8 figures Revised, added details on simulations,
4 tables, 9 figure
Search for Branons at LEP
We search, in the context of extra-dimension scenarios, for the possible
existence of brane fluctuations, called branons. Events with a single photon or
a single Z-boson and missing energy and momentum collected with the L3 detector
in e^+ e^- collisions at centre-of-mass energies sqrt{s}=189-209$ GeV are
analysed. No excess over the Standard Model expectations is found and a lower
limit at 95% confidence level of 103 GeV is derived for the mass of branons,
for a scenario with small brane tensions. Alternatively, under the assumption
of a light branon, brane tensions below 180 GeV are excluded
Event-by-Event Fluctuations in Particle Multiplicities and Transverse Energy Produced in 158.A GeV Pb+Pb collisions
Event-by-event fluctuations in the multiplicities of charged particles and
photons, and the total transverse energy in 158 GeV Pb+Pb collisions
are studied for a wide range of centralities. For narrow centrality bins the
multiplicity and transverse energy distributions are found to be near perfect
Gaussians. The effect of detector acceptance on the multiplicity fluctuations
has been studied and demonstrated to follow statistical considerations. The
centrality dependence of the charged particle multiplicity fluctuations in the
measured data has been found to agree reasonably well with those obtained from
a participant model. However for photons the multiplicity fluctuations has been
found to be lower compared to those obtained from a participant model. The
multiplicity and transverse energy fluctuations have also been compared to
those obtained from the VENUS event generator.Comment: To appear in Physical Review C; changes : more detailed discussion on
errors and few figures modifie
- …