Accurate mass measurements of Ne, Na, Mg performed with the {\sc Mistral} spectrometer
The minuteness of the nuclear binding energy requires that mass measurements
be highly precise and accurate. Here we report on new measurements Mg
and Na performed with the {\sc Mistral} mass spectrometer at {\sc
Cern}'s {\sc Isolde} facility. Since mass measurements are prone to systematic
errors, considerable effort has been devoted to their evaluation and
elimination in order to achieve accuracy and not only precision. We have
therefore conducted a campaign of measurements for calibration and error
evaluation. As a result, we now have a satisfactory description of the {\sc
Mistral} calibration laws and error budget. We have applied our new
understanding to previous measurements of Ne, Na and
Mg for which re-evaluated values are reported.Comment: submitted to Nuclear Physics
Ferromagnetism in substituted zinc oxide
Room-temperature ferromagnetism is observed in (110) oriented ZnO films
containing 5 at % of Sc, Ti, V, Fe, Co or Ni, but not Cr, Mn or Cu ions. There
are large moments, 1.9 and 0.5 muB/atom for Co- and Ti-substituted oxides,
respectively. Sc-substituted ZnO shows also a moment of 0.3 muB/Sc.
Magnetization is very anisotropic, with variations of up to a factor three
depending on the orientation of the applied field relative to the R-cut
sapphire substrates. Results are interpreted in terms of a spin-split donor
impurity band model, which can account for ferromagnetism in insulating or
conducting high-k oxides with concentrations of magnetic ions that lie far
below the percolation threshold. The variation of the ferromagnetism with
oxygen pressure used during film growth is evidence of a link between
ferromagnetism and defect concentration.Comment: 15 pages, 4 figure
Evidence for a breakdown of the Isobaric Multiplet Mass Equation: A study of the A=35, T=3/2 isospin quartet
Mass measurements on radionuclides along the potassium isotope chain have
been performed with the ISOLTRAP Penning trap mass spectrometer. For 35K
T1/2=178ms) to 46K (T1/2=105s) relative mass uncertainties of 2x10-8 and better
have been achieved. The accurate mass determination of 35K (dm=0.54keV) has
been exploited to test the Isobaric Multiplet Mass Equation (IMME) for the
A=35, T=3/2 isospinquartet. The experimental results indicate a deviation from
the generally adopted quadratic form.Comment: 8 pages, 4 figure
First Penning-trap mass measurement in the millisecond half-life range: the exotic halo nucleus 11Li
In this letter, we report a new mass for Li using the trapping
experiment TITAN at TRIUMF's ISAC facility. This is by far the shortest-lived
nuclide, , for which a mass measurement has ever been
performed with a Penning trap. Combined with our mass measurements of
Li we derive a new two-neutron separation energy of 369.15(65) keV: a
factor of seven more precise than the best previous value. This new value is a
critical ingredient for the determination of the halo charge radius from
isotope-shift measurements. We also report results from state-of-the-art
atomic-physics calculations using the new mass and extract a new charge radius
for Li. This result is a remarkable confluence of nuclear and atomic
physics.Comment: Formatted for submission to PR
Probing the N = 32 shell closure below the magic proton number Z = 20: Mass measurements of the exotic isotopes 52,53K
The recently confirmed neutron-shell closure at N = 32 has been investigated
for the first time below the magic proton number Z = 20 with mass measurements
of the exotic isotopes 52,53K, the latter being the shortest-lived nuclide
investigated at the online mass spectrometer ISOLTRAP. The resulting
two-neutron separation energies reveal a 3 MeV shell gap at N = 32, slightly
lower than for 52Ca, highlighting the doubly-magic nature of this nuclide.
Skyrme-Hartree-Fock-Boguliubov and ab initio Gorkov-Green function calculations
are challenged by the new measurements but reproduce qualitatively the observed
shell effect.Comment: 5 pages, 5 figure
HiPERCAM: A high-speed quintuple-beam CCD camera for the study of rapid variability in the universe
HiPERCAM is a high-speed camera for the study of rapid variability in the Universe. The project is funded by a ϔ3.5M European Research Council Advanced Grant. HiPERCAM builds on the success of our previous instrument, ULTRACAM, with very significant improvements in performance thanks to the use of the latest technologies. HiPERCAM will use 4 dichroic beamsplitters to image simultaneously in 5 optical channels covering the u'g'r'I'z' bands. Frame rates of over 1000 per second will be achievable using an ESO CCD controller (NGC), with every frame GPS timestamped. The detectors are custom-made, frame-transfer CCDs from e2v, with 4 low noise (2.5e -) outputs, mounted in small thermoelectrically-cooled heads operated at 180 K, resulting in virtually no dark current. The two reddest CCDs will be deep-depletion devices with anti-etaloning, providing high quantum efficiencies across the red part of the spectrum with no fringing. The instrument will also incorporate scintillation noise correction via the conjugate-plane photometry technique. The opto-mechanical chassis will make use of additive manufacturing techniques in metal to make a light-weight, rigid and temperature-invariant structure. First light is expected on the 4.2m William Herschel Telescope on La Palma in 2017 (on which the field of view will be 10' with a 0.3"/pixel scale), with subsequent use planned on the 10.4m Gran Telescopio Canarias on La Palma (on which the field of view will be 4' with a 0.11"/pixel scale) and the 3.5m New Technology Telescope in Chile
Assessment of Global Kidney Health Care Status.
Kidney disease is a substantial worldwide clinical and public health problem, but information about available care is limited.To collect information on the current state of readiness, capacity, and competence for the delivery of kidney care across countries and regions of the world.Questionnaire survey administered from May to September 2016 by the International Society of Nephrology (ISN) to 130 ISN-affiliated countries with sampling of key stakeholders (national nephrology society leadership, policy makers, and patient organization representatives) identified by the country and regional nephrology leadership through the ISN.Core areas of country capacity and response for kidney care.Responses were received from 125 of 130 countries (96%), including 289 of 337 individuals (85.8%, with a median of 2 respondents [interquartile range, 1-3]), representing an estimated 93% (6.8 billion) of the world's population of 7.3 billion. There was wide variation in country readiness, capacity, and response in terms of service delivery, financing, workforce, information systems, and leadership and governance. Overall, 119 (95%), 95 (76%), and 94 (75%) countries had facilities for hemodialysis, peritoneal dialysis, and kidney transplantation, respectively. In contrast, 33 (94%), 16 (45%), and 12 (34%) countries in Africa had facilities for hemodialysis, peritoneal dialysis, and kidney transplantation, respectively. For chronic kidney disease (CKD) monitoring in primary care, serum creatinine with estimated glomerular filtration rate and proteinuria measurements were reported as always available in only 21 (18%) and 9 (8%) countries, respectively. Hemodialysis, peritoneal dialysis, and transplantation services were funded publicly and free at the point of care delivery in 50 (42%), 48 (51%), and 46 (49%) countries, respectively. The number of nephrologists was variable and was low (<10 per million population) in Africa, the Middle East, South Asia, and Oceania and South East Asia (OSEA) regions. Health information system (renal registry) availability was limited, particularly for acute kidney injury (8 countries [7%]) and nondialysis CKD (9 countries [8%]). International acute kidney injury and CKD guidelines were reportedly accessible in 52 (45%) and 62 (52%) countries, respectively. There was relatively low capacity for clinical studies in developing nations.This survey demonstrated significant interregional and intraregional variability in the current capacity for kidney care across the world, including important gaps in services and workforce. Assuming the responses accurately reflect the status of kidney care in the respondent countries, the findings may be useful to inform efforts to improve the quality of kidney care worldwide
Development of a PbWO4 Detector for Single-Shot Positron Annihilation Lifetime Spectroscopy at the GBAR Experiment
We have developed a PbWO4 (PWO) detector with a large dynamic range to measure the intensity of a positron beam and the absolute density of the ortho-positronium (o-Ps) cloud it creates. A simulation study shows that a setup based on such detectors may be used to determine the angular distribution of the emission and reflection of o-Ps to reduce part of the uncertainties of the measurement. These will allow to improve the precision in the measurement of the cross-section for the (anti)hydrogen formation by (anti)proton-positronium charge exchange and to optimize the yield of antihydrogen ion which is an essential parameter in the GBAR experiment
- âŠ