144 research outputs found

    Addition of hyaluronic acid improves tlerance to 7% hypertonic saline solution in bronchiectasis patients.

    Get PDF
    Background: The excessive retention of sputum in the airways, leading to pulmonary infections, is a common consequence of bronchiectasis. Although inhalation of 7% hypertonic saline (HS) has proven an effective method to help remove the mucus, many patients are intolerant of this treatment. The addition of 0.1% hyaluronic acid to HS (HS+HA) could increase tolerance to HS in these patients. The main objective of this study was to evaluate the tolerability of HS+HA in bronchiectasis patients who are intolerant to HS. Methods: This prospective, observational, open-label study analysed the outcomes of two groups of bronchiectasis patients previously scheduled to start HS therapy. Patients were assessed for tolerance to HS by a questionnaire, spirometry and clinical evaluation. Patients who were intolerant were evaluated for tolerance to HS+HA approximately one week later. All patients were evaluated for their tolerance to HS or HS+HA 4 weeks after the start of their treatment. Patients were also assessed with quality-of-life and adherence questionnaires, and all adverse events were registered. Results: A total of 137 bronchiectasis patients were enrolled in the study (age = 63.0 ± 14.7 years; 63.5% women). Of these, 92 patients (67.1%) were tolerant and 45 patients (32.9%) were intolerant to HS. Of the 45 patients intolerant to HS, 31 patients (68.9%) were tolerant and 14 patients (31.1%) intolerant to HS+HA. Of these 31 tolerant patients, 26 (83.9%) could complete the 4-week treatment with HS+HA. Conclusions: Two-thirds of bronchiectasis patients that presented intolerance to inhaled HS alone are tolerant to inhaled HS+HA, suggesting that HA improves tolerance to HS therapy

    Improvement of Fatigue Life and Surface Properties of Metallic Materials of Biomedical Interest by Laser Shock Processing

    Get PDF
    Laser Shock Processing (LSP) is developed as a technique allowing the effective induction of residual stresses fields in metallic materials allowing a high degree of surface material protection against fatigue crack propagation, abrasive wear, chemical corrosion and other failure conditions, what makes the technique specially suitable and competitive with presently use techniques for the treatment of heavy duty components in the aeronautical, nuclear and automotive industries. The highly beneficial effect of LSP treatments has been demonstrated in the extension of life of test specimens with induced surface notches. The application of the LSP treatment to concrete high reliability components, particularly in the field of metallic materials of biomedical interest is envisaged. In the present communication, several experimental examples of the effects introduced in this kind of materials are shown along with some computational design tools developed in relation with typical prosthetical components. Additionally, the prospects for the application of the LSP treatment to new/advanced materials of biomedical interest are discussed

    Efficacy of laser shock processing of biodegradable Mg and Mg-1Zn alloy on their in vitro corrosion and bacterial response

    Get PDF
    Laser shock processing (LSP) is increasingly applied as an effective technology for improving the properties of different metallic components. This is done principally to enhance their corrosion and fatigue life behaviour, stress corrosion cracking resistance, etc. In this paper, LSP has been applied to a commercially pure Mg and a Mg-1Zn alloy (wt%) which is aimed to be used as a biodegradable material for biomedical applications. The rational for microalloying with Zn is not only influencing the bacterial response, but also enhancing corrosion resistance and mechanical strength of Mg without causing any toxic effect. The present work is focussed on the examination of the effects of the LSP treatment on the relevant surface related properties of the samples and their correlation with the surface and subsurface induced modifications such as residual stress state, microstructural, roughness, hardness, etc. Central to this investigation is the study of the corrosion response and antibacterial properties against Staphylococcus epidermidis of the different samples as a function of material and LSP parameters. The results show that the application of LSP introduces compressive residual stresses up to 1 mm deep. This occurs together with a significant improvement in corrosion resistance, and less bacterial colonization.Peer reviewe

    Bronchoscopist's perception of the quality of the single-use bronchoscope (Ambu aScope4ℱ) in selected bronchoscopies: a multicenter study in 21 Spanish pulmonology services

    Get PDF
    Background: The disposable bronchoscope is an excellent alternative to face the problem of SARS-CoV-2 and other cross infections, but the bronchoscopist's perception of its quality has not been evaluated. Methods: To evaluate the quality of the Ambu-aScope4 disposable bronchoscope, we carried out a cross-sectional study in 21 Spanish pulmonology services. We use a standardized questionnaire completed by the bronchoscopists at the end of each bronchoscopy. The variables were described with absolute and relative frequencies, measures of central tendency and dispersion depending on their nature. The existence of learning curves was evaluated by CUSUM analysis. Results: The most frequent indications in 300 included bronchoscopies was bronchial aspiration in 69.3% and the median duration of these was 9.1 min. The route of entry was nasal in 47.2% and oral in 34.1%. The average score for ease of use, image, and aspiration quality was 80/100. All the planned techniques were performed in 94.9% and the bronchoscopist was satisfied in 96.6% of the bronchoscopies. They highlighted the portability and immediacy of the aScope4TM to start the procedure in 99.3%, the possibility of taking and storing images in 99.3%. The CUSUM analysis showed average scores > 70/100 from the first procedure and from the 9th procedure more than 80% of the scores exceeded the 80/100 score. Conclusions: The aScope4ℱ scored well for ease of use, imaging, and aspiration. We found a learning curve with excellent scores from the 9th procedure. Bronchoscopists highlighted its portability, immediacy of use and the possibility of taking and storing images

    Bronchoscopist's perception of the quality of the single-use bronchoscope (Ambu aScope4ℱ) in selected bronchoscopies: a multicenter study in 21 Spanish pulmonology services

    Get PDF
    Background: The disposable bronchoscope is an excellent alternative to face the problem of SARS-CoV-2 and other cross infections, but the bronchoscopist’s perception of its quality has not been evaluated. Methods: To evaluate the quality of the Ambu-aScope4 disposable bronchoscope, we carried out a cross-sectional study in 21 Spanish pulmonology services. We use a standardized questionnaire completed by the bronchoscopists at the end of each bronchoscopy. The variables were described with absolute and relative frequencies, measures of cen‑ tral tendency and dispersion depending on their nature. The existence of learning curves was evaluated by CUSUM analysis. Results: The most frequent indications in 300 included bronchoscopies was bronchial aspiration in 69.3% and the median duration of these was 9.1 min. The route of entry was nasal in 47.2% and oral in 34.1%. The average score for ease of use, image, and aspiration quality was 80/100. All the planned techniques were performed in 94.9% and the bronchoscopist was satisfed in 96.6% of the bronchoscopies. They highlighted the portability and immediacy of the aScope4TM to start the procedure in 99.3%, the possibility of taking and storing images in 99.3%. The CUSUM analysis showed average scores>70/100 from the frst procedure and from the 9th procedure more than 80% of the scores exceeded the 80/100 score

    Bronchoscopist's perception of the quality of the single-use bronchoscope (Ambu aScope4ℱ) in selected bronchoscopies : a multicenter study in 21 Spanish pulmonology services

    Get PDF
    Background: The disposable bronchoscope is an excellent alternative to face the problem of SARS-CoV-2 and other cross infections, but the bronchoscopist's perception of its quality has not been evaluated. Methods: To evaluate the quality of the Ambu-aScope4 disposable bronchoscope, we carried out a cross-sectional study in 21 Spanish pulmonology services. We use a standardized questionnaire completed by the bronchoscopists at the end of each bronchoscopy. The variables were described with absolute and relative frequencies, measures of central tendency and dispersion depending on their nature. The existence of learning curves was evaluated by CUSUM analysis. Results: The most frequent indications in 300 included bronchoscopies was bronchial aspiration in 69.3% and the median duration of these was 9.1 min. The route of entry was nasal in 47.2% and oral in 34.1%. The average score for ease of use, image, and aspiration quality was 80/100. All the planned techniques were performed in 94.9% and the bronchoscopist was satisfied in 96.6% of the bronchoscopies. They highlighted the portability and immediacy of the aScope4TM to start the procedure in 99.3%, the possibility of taking and storing images in 99.3%. The CUSUM analysis showed average scores > 70/100 from the first procedure and from the 9th procedure more than 80% of the scores exceeded the 80/100 score. Conclusions: The aScope4ℱ scored well for ease of use, imaging, and aspiration. We found a learning curve with excellent scores from the 9th procedure. Bronchoscopists highlighted its portability, immediacy of use and the possibility of taking and storing images

    A922 Sequential measurement of 1 hour creatinine clearance (1-CRCL) in critically ill patients at risk of acute kidney injury (AKI)

    Get PDF
    Meeting abstrac
    • 

    corecore