6 research outputs found

    Tumour-derived PGD2 and NKp30-B7H6 engagement drives an immunosuppressive ILC2-MDSC axis.

    Get PDF
    Group 2 innate lymphoid cells (ILC2s) are involved in human diseases, such as allergy, atopic dermatitis and nasal polyposis, but their function in human cancer remains unclear. Here we show that, in acute promyelocytic leukaemia (APL), ILC2s are increased and hyper-activated through the interaction of CRTH2 and NKp30 with elevated tumour-derived PGD2 and B7H6, respectively. ILC2s, in turn, activate monocytic myeloid-derived suppressor cells (M-MDSCs) via IL-13 secretion. Upon treating APL with all-trans retinoic acid and achieving complete remission, the levels of PGD2, NKp30, ILC2s, IL-13 and M-MDSCs are restored. Similarly, disruption of this tumour immunosuppressive axis by specifically blocking PGD2, IL-13 and NKp30 partially restores ILC2 and M-MDSC levels and results in increased survival. Thus, using APL as a model, we uncover a tolerogenic pathway that may represent a relevant immunosuppressive, therapeutic targetable, mechanism operating in various human tumour types, as supported by our observations in prostate cancer.Group 2 innate lymphoid cells (ILC2s) modulate inflammatory and allergic responses, but their function in cancer immunity is still unclear. Here the authors show that, in acute promyelocytic leukaemia, tumour-activated ILC2s secrete IL-13 to induce myeloid-derived suppressor cells and support tumour growth

    Assessment of droplet digital polymerase chain reaction for measuring BCR-ABL1 in chronic myeloid leukaemia in an international interlaboratory study

    Get PDF
    Measurement of BCR activator of RhoGEF and GTPase -ABL proto-oncogene 1, non-receptor tyrosine kinase (BCR-ABL1) mRNA levels by reverse transcription quantitative polymerase chain reaction (RTqPCR) has been critical to treatment protocols and clinical trials in chronic myeloid leukaemia; however, interlaboratory variation remains a significant issue. Reverse transcriptase droplet digital PCR (RTddPCR) has shown potential to improve testing but a large-scale interlaboratory study is required to definitively establish this. In the present study, 10 BCR-ABL1-positive samples with levels ranging from molecular response (MR)1·0–MR5·0 were tested by 23 laboratories using RTddPCR with the QXDX BCR-ABL %IS kit. A subset of participants tested the samples using RTqPCR. All 23 participants using RTddPCR detected BCR-ABL1 in all samples to MR4·0. Detection rates for deep-response samples were 95·7% at MR4·5, 78·3% at MR4·7 and 87·0% at MR5·0. Interlaboratory coefficient of variation was indirectly proportional to BCR-ABL1 level ranging from 29·3% to 69·0%. Linearity ranged from 0·9330 to 1·000 (average 0·9936). When results were compared for the 11 participants who performed both RTddPCR and RTqPCR, RTddPCR showed a similar limit of detection to RTqPCR with reduced interlaboratory variation and better assay linearity. The ability to detect deep responses with RTddPCR, matched with an improved linearity and reduced interlaboratory variation will allow improved patient management, and is of particular importance for future clinical trials focussed on achieving and maintaining treatment-free remission

    A certified plasmid reference material for the standardisation of BCR-ABL1 mRNA quantification by real-time quantitative PCR

    Get PDF
    Serial quantification of BCR–ABL1 mRNA is an important therapeutic indicator in chronic myeloid leukaemia, but there is a substantial variation in results reported by diff

    A certified plasmid reference material for the standardisation of BCR-ABL1 mRNA quantification by real time quantitative PCR

    Get PDF
    Serial quantification of BCR–ABL1 mRNA is an important therapeutic indicator in chronic myeloid leukaemia, but there is a substantial variation in results reported by different laboratories. To improve comparability, an internationally accepted plasmid certified reference material (CRM) was developed according to ISO Guide 34:2009. Fragments of BCR–ABL1 (e14a2 mRNA fusion), BCR and GUSB transcripts were amplified and cloned into pUC18 to yield plasmid pIRMM0099. Six different linearised plasmid solutions were produced with the following copy number concentrations, assigned by digital PCR, and expanded uncertainties: 1.08±0.13 × 106, 1.08±0.11 × 105, 1.03±0.10 × 104, 1.02±0.09 × 103, 1.04±0.10 × 102 and 10.0±1.5 copies/?l. The certification of the material for the number of specific DNA fragments per plasmid, copy number concentration of the plasmid solutions and the assessment of inter-unit heterogeneity and stability were performed according to ISO Guide 35:2006. Two suitability studies performed by 63 BCR–ABL1 testing laboratories demonstrated that this set of 6 plasmid CRMs can help to standardise a number of measured transcripts of e14a2 BCR–ABL1 and three control genes (ABL1, BCR and GUSB). The set of six plasmid CRMs is distributed worldwide by the Institute for Reference Materials and Measurements (Belgium) and its authorised distributors (https://ec.europa.eu/jrc/en/reference-materials/catalogue/; CRM code ERM-AD623a-f)
    corecore