1,819 research outputs found
Bayesian photon counting with electron-multiplying charge coupled devices (EMCCDs)
The EMCCD is a CCD type that delivers fast readout and negligible detector
noise, making it an ideal detector for high frame rate applications. Because of
the very low detector noise, this detector can potentially count single
photons. Considering that an EMCCD has a limited dynamical range and negligible
detector noise, one would typically apply an EMCCD in such a way that multiple
images of the same object are available, for instance, in so called lucky
imaging. The problem of counting photons can then conveniently be viewed as
statistical inference of flux or photon rates, based on a stack of images. A
simple probabilistic model for the output of an EMCCD is developed. Based on
this model and the prior knowledge that photons are Poisson distributed, we
derive two methods for estimating the most probable flux per pixel, one based
on thresholding, and another based on full Bayesian inference. We find that it
is indeed possible to derive such expressions, and tests of these methods show
that estimating fluxes with only shot noise is possible, up to fluxes of about
one photon per pixel per readout.Comment: Fixed a few typos compared to the published versio
Quantum squeezing of optical dissipative structures
We show that any optical dissipative structure supported by degenerate
optical parametric oscillators contains a special transverse mode that is free
from quantum fluctuations when measured in a balanced homodyne detection
experiment. The phenomenon is not critical as it is independent of the system
parameters and, in particular, of the existence of bifurcations. This result is
a consequence of the spatial symmetry breaking introduced by the dissipative
structure. Effects that could degrade the squeezing level are considered.Comment: 4 pages and a half, 1 fugure. Version to appear in Europhysics
Letter
Ultrafast surface carrier dynamics in the topological insulator Bi2Te3
We discuss the ultrafast evolution of the surface electronic structure of the
topological insulator BiTe following a femtosecond laser excitation.
Using time and angle resolved photoelectron spectroscopy, we provide a direct
real-time visualisation of the transient carrier population of both the surface
states and the bulk conduction band. We find that the thermalization of the
surface states is initially determined by interband scattering from the bulk
conduction band, lasting for about 0.5 ps; subsequently, few ps are necessary
for the Dirac cone non-equilibrium electrons to recover a Fermi-Dirac
distribution, while their relaxation extends over more than 10 ps. The surface
sensitivity of our measurements makes it possible to estimate the range of the
bulk-surface interband scattering channel, indicating that the process is
effective over a distance of 5 nm or less. This establishes a correlation
between the nanoscale thickness of the bulk charge reservoir and the evolution
of the ultrafast carrier dynamics in the surface Dirac cone
On the correspondence between surface UV observations and TOMS determinations of surface UV: a potential method for quality evaluating world surface UV observations
A comparison of erythemally weighted surface UV irradiance observations with similar NASA TOMS surface UV
determinations is described. Comparisons are made for two observation periods: the Robertson-Berger (R-B) meter period
from 1974 to the late 1980s and the current period from 1996 to the present when more sophisticated UVB-1 instruments
were used. The more primitive R-B meter observations that comprised the fi rst U.S. UV network are seen to drift downward
with respect to those of the TOMS. While the UVB-1 observations did not appear to drift, a substantial bias is noted to exist
between the TOMS and the UVB-1 stations collecting observations; the TOMS estimations tend to be higher. A portion of the
bias may be attributed to errors in calibration, total ozone, and cosine response of the surface instrumentation. Unaccounted
aerosol effects, although not considered to be large in the TOMS estimations, present another source of error. Comparisons
are fi rst done for all sky conditions and then for clear sky conditions. The biases typically agree for all sky conditions
within the uncertainties of the surface instruments' calibrations, liberally defi ned as ± 5%, implying that the TOMS cloud
correction scheme performs reasonably well. Snow cover severely impacts the TOMS observations, giving considerably
higher estimations. The biases for clear sky conditions ranged from 15% to 19% with no obvious drifts between the satellite
and surface observations. The variation in the biases among stations is within the calibration uncertainties of the instruments,
but the absolute bias is unexpectedly large. The standard deviations of the clear sky comparisons among all stations are steady
at 4.8% ± 0.7%. A plot of the TOMS/UVB-1 ratio versus TOMS cloud refl ectivity observations is noisy, but qualitatively
suggestive of a possible slight increase (~ 5% or greater) over the range of clear to overcast skies. The results from these
comparisons is believed to be relevant to a WMO goal of uniformly assuring the quality of UV observations made by networks
in many countries. The results for clear sky comparisons suggest that a satellite observing system such as TOMS, which
provides global coverage daily, might partially serve as a fi rst-order check to quality assure UV observations being made by
networks worldwide. Future research should concentrate on determining the causes of the large differences seen between
the UVB-1 and TOMS and the range of uncertainties, using a larger array of stations
Frequency domain EEG source localization of ictal epileptiform activity in patients with partial complex epilepsy of temporal lobe origin
The aim of this study was to investigate whether EEG source localization in the frequency domain, using the FFT dipole approximation (Lehmann, D. and Michel, C.M. Electroenceph. clin. Neurophysiol., 1990, 76: 271-276), would be useful for quantifying the frequency content of epileptic seizure activity. Between one and 7 extracranially recorded seizures were analyzed in each of 7 patients with mesolimbic epilepsy, who were seizure-free after temporal lobe resection. The full scalp frequency spectrum for the first 4 s after seizure onset, as well as for subsequent periods, was determined. Power peaks in the spectra were identified, and an instant dipole fit was performed for the frequencies corresponding to these peaks. Ictal frequencies, ranging between 3.5 and 8.5 Hz, showed a variable degree of stability over time in the different patients. For a particular frequency, dipole results were similar during the different phases of seizure development. In patients with more than one prominent frequency, dipole results for the different frequencies were similar. Dipole results were also similar between patients. We conclude that dipole localization of dominant frequencies, as obtained from full scalp FFT analysis, gives quite reproducible results for seizures originating in the mesial temporal area. The method may become a useful tool for the pre-surgical identification of patients with mesolimbic epilepsy
Electroencephalographic source imaging: a prospective study of 152 operated epileptic patients
Electroencephalography is mandatory to determine the epilepsy syndrome. However, for the precise localization of the irritative zone in patients with focal epilepsy, costly and sometimes cumbersome imaging techniques are used. Recent small studies using electric source imaging suggest that electroencephalography itself could be used to localize the focus. However, a large prospective validation study is missing. This study presents a cohort of 152 operated patients where electric source imaging was applied as part of the pre-surgical work-up allowing a comparison with the results from other methods. Patients (n = 152) with >1 year postoperative follow-up were studied prospectively. The sensitivity and specificity of each imaging method was defined by comparing the localization of the source maximum with the resected zone and surgical outcome. Electric source imaging had a sensitivity of 84% and a specificity of 88% if the electroencephalogram was recorded with a large number of electrodes (128–256 channels) and the individual magnetic resonance image was used as head model. These values compared favourably with those of structural magnetic resonance imaging (76% sensitivity, 53% specificity), positron emission tomography (69% sensitivity, 44% specificity) and ictal/interictal single-photon emission-computed tomography (58% sensitivity, 47% specificity). The sensitivity and specificity of electric source imaging decreased to 57% and 59%, respectively, with low number of electrodes (<32 channels) and a template head model. This study demonstrated the validity and clinical utility of electric source imaging in a large prospective study. Given the low cost and high flexibility of electroencephalographic systems even with high channel counts, we conclude that electric source imaging is a highly valuable tool in pre-surgical epilepsy evaluation
DC-electric-field-induced and low-frequency electromodulation second-harmonic generation spectroscopy of Si(001)-SiO interfaces
The mechanism of DC-Electric-Field-Induced Second-Harmonic (EFISH) generation
at weakly nonlinear buried Si(001)-SiO interfaces is studied experimentally
in planar Si(001)-SiO-Cr MOS structures by optical second-harmonic
generation (SHG) spectroscopy with a tunable Ti:sapphire femtosecond laser. The
spectral dependence of the EFISH contribution near the direct two-photon
transition of silicon is extracted. A systematic phenomenological model of the
EFISH phenomenon, including a detailed description of the space charge region
(SCR) at the semiconductor-dielectric interface in accumulation, depletion, and
inversion regimes, has been developed. The influence of surface quantization
effects, interface states, charge traps in the oxide layer, doping
concentration and oxide thickness on nonlocal screening of the DC-electric
field and on breaking of inversion symmetry in the SCR is considered. The model
describes EFISH generation in the SCR using a Green function formalism which
takes into account all retardation and absorption effects of the fundamental
and second harmonic (SH) waves, optical interference between field-dependent
and field-independent contributions to the SH field and multiple reflection
interference in the SiO layer. Good agreement between the phenomenological
model and our recent and new EFISH spectroscopic results is demonstrated.
Finally, low-frequency electromodulated EFISH is demonstrated as a useful
differential spectroscopic technique for studies of the Si-SiO interface in
silicon-based MOS structures.Comment: 31 pages, 14 figures, 1 table, figures are also available at
http://kali.ilc.msu.su/articles/50/efish.ht
Spectroscopy of 32Ne and the Island of Inversion
We report on the first spectroscopic study of the N=22 nucleus 32Ne at the
newly completed RIKEN Radioactive Ion Beam Factory. A single gamma-ray line
with an energy of 722(9) keV was observed in both inelastic scattering of a 226
MeV/u 32Ne beam on a Carbon target and proton removal from 33Na at 245 MeV/u.
This transition is assigned to the de-excitation of the first J^pi = 2+ state
in 32Ne to the 0+ ground state. Interpreted through comparison with
state-of-the-art shell model calculations, the low excitation energy
demonstrates that the Island of Inversion extends to at least N=22 for the Ne
isotopes.Comment: Accepted for publication in Phys. Rev. Lett. 11 pages, 3 figure
- …