3,018 research outputs found

    Real-time live-cell imaging technology enables high-throughput screening to verify in vitro biocompatibility of 3D printed materials

    Get PDF
    With growing advances in three-dimensional (3D) printing technology, the availability and diversity of printing materials has rapidly increased over the last years. 3D printing has quickly become a useful tool for biomedical and various laboratory applications, offering a tremendous potential for efficiently fabricating complex devices in a short period of time. However, there still remains a lack of information regarding the impact of printing materials and post-processing techniques on cell behavior. This study introduces real-time live-cell imaging technology as a fast, user-friendly, and high-throughput screening strategy to verify the in vitro biocompatibility of 3D printed materials. Polyacrylate-based photopolymer material was printed using high-resolution 3D printing techniques, post-processed using three different procedures, and then analyzed with respect to its effects on cell viability, apoptosis, and necrosis of adipogenic mesenchymal stem cells (MSCs). When using ethanol for the post-processing procedure and disinfection, no significant effects on MSCs could be detected. For the analyses a novel image-based live-cell analysis system was compared against a biochemical-based standard plate reader assay and traditional flow cytometry. This comparison illustrates the superiority of using image-based detection of in vitro biocompatibility with respect to analysis time, usability, and scientific outcome

    Automation and validation of micronucleus detection in the 3D EpiDerm™ human reconstructed skin assay and correl

    Get PDF
    Recent restrictions on the testing of cosmetic ingredients in animals have resulted in the need to test the genotoxic potential of chemicals exclusively in vitro prior to licensing. However, as current in vitro tests produce some misleading positive results, sole reliance on such tests could prevent some chemicals with safe or beneficial exposure levels from being marketed. The 3D human reconstructed skin micronucleus (RSMN) assay is a promising new in vitro approach designed to assess genotoxicity of dermally applied compounds. The assay utilises a highly differentiated in vitro model of the human epidermis. For the first time, we have applied automated micronucleus detection to this assay using MetaSystems Metafer Slide Scanning Platform (Metafer), demonstrating concordance with manual scoring. The RSMN assay's fixation protocol was found to be compatible with the Metafer, providing a considerably shorter alternative to the recommended Metafer protocol. Lowest observed genotoxic effect levels (LOGELs) were observed for mitomycin-C at 4.8 μg/ ml and methyl methanesulfonate (MMS) at 1750 μg/ml when applied topically to the skin surface. In-medium dosing with MMS produced a LOGEL of 20 μg/ml, which was very similar to the topical LOGEL when considering the total mass of MMS added. Comparisons between 3D medium and 2D LOGELs resulted in a 7-fold difference in total mass of MMS applied to each system, suggesting a protective function of the 3D microarchitecture. Interestingly, hydrogen peroxide (H2O 2), a positive clastogen in 2D systems, tested negative in this assay. A non-genotoxic carcinogen, methyl carbamate, produced negative results, as expected. We also demonstrated expression of the DNA repair protein N-methylpurine-DNA glycosylase in EpiDerm™. Our preliminary validation here demonstrates that the RSMN assay may be a valuable followup to the current in vitro test battery, and together with its automation, could contribute to minimising unnecessary in vivo tests by reducing in vitro misleading positives. © The Author 2014

    The equivalence of fluctuation scale dependence and autocorrelations

    Full text link
    We define optimal per-particle fluctuation and correlation measures, relate fluctuations and correlations through an integral equation and show how to invert that equation to obtain precise autocorrelations from fluctuation scale dependence. We test the precision of the inversion with Monte Carlo data and compare autocorrelations to conditional distributions conventionally used to study high-ptp_t jet structure.Comment: 10 pages, 9 figures, proceedings, MIT workshop on correlations and fluctuations in relativistic nuclear collision

    Considering the case for an antidepressant drug trial involving temporary deception: a qualitative enquiry of potential participants

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Systematic reviews of randomised placebo controlled trials of antidepressant medication show small and decreasing differences between pharmacological and placebo arms. In part this finding may relate to methodological problems with conventional trial designs, including their assumption of additivity between drug and placebo trial arms. Balanced placebo designs, which include elements of deception, may address the additivity question, but pose substantial ethical and pragmatic problems. This study aimed to ascertain views of potential study participants of the ethics and pragmatics of various balanced placebo designs, in order to inform the design of future antidepressant drug trials.</p> <p>Methods</p> <p>A qualitative approach was employed to explore the perspectives of general practitioners, psychiatrists, and patients with experience of depression. The doctors were chosen via purposive sampling, while patients were recruited through participating general practitioners. Three focus groups and 12 in-depth interviews were conducted. A vignette-based topic guide invited views on three deceptive strategies: post hoc, authorised and minimised deception. The focus groups and interviews were tape-recorded and transcribed. Transcripts were analysed thematically using Framework.</p> <p>Results</p> <p>Deception in non-research situations was typically perceived as acceptable within specific parameters. All participants could see the potential utility of introducing deception into trial designs, however views on the acceptability of deception within antidepressant drug trials varied substantially. Authorized deception was the most commonly accepted strategy, though some thought this would reduce the effectiveness of the design because participants would correctly guess the deceptive element. The major issues that affected views about the acceptability of deception studies were the welfare and capacity of patients, practicalities of trial design, and the question of trust.</p> <p>Conclusion</p> <p>There is a trade-off between pragmatic and ethical responses to the question of whether, and under what circumstances, elements of deception could be introduced into antidepressant drug trials. Ensuring adequate ethical safeguards within balanced placebo designs is likely to diminish their ability to address the crucial issue of additivity. The balanced placebo designs considered in this study are unlikely to be feasible in future trials of antidepressant medication. However there remains an urgent need to improve the quality of antidepressant drug trials.</p

    Constructing living buildings: a review of relevant technologies for a novel application of biohybrid robotics

    Get PDF
    Biohybrid robotics takes an engineering approach to the expansion and exploitation of biological behaviours for application to automated tasks. Here, we identify the construction of living buildings and infrastructure as a high-potential application domain for biohybrid robotics, and review technological advances relevant to its future development. Construction, civil infrastructure maintenance and building occupancy in the last decades have comprised a major portion of economic production, energy consumption and carbon emissions. Integrating biological organisms into automated construction tasks and permanent building components therefore has high potential for impact. Live materials can provide several advantages over standard synthetic construction materials, including self-repair of damage, increase rather than degradation of structural performance over time, resilience to corrosive environments, support of biodiversity, and mitigation of urban heat islands. Here, we review relevant technologies, which are currently disparate. They span robotics, self-organizing systems, artificial life, construction automation, structural engineering, architecture, bioengineering, biomaterials, and molecular and cellular biology. In these disciplines, developments relevant to biohybrid construction and living buildings are in the early stages, and typically are not exchanged between disciplines. We, therefore, consider this review useful to the future development of biohybrid engineering for this highly interdisciplinary application.publishe

    Combined written and oral information prior to gastrointestinal endoscopy compared with oral information alone: a randomized trial

    Get PDF
    BACKGROUND: Little is known about how to most effectively deliver relevant information to patients scheduled for endoscopy. METHODS: To assess the effects of combined written and oral information, compared with oral information alone on the quality of information before endoscopy and the level of anxiety. We designed a prospective study in two Swiss teaching hospitals which enrolled consecutive patients scheduled for endoscopy over a three-month period. Patients were randomized either to receiving, along with the appointment notice, an explanatory leaflet about the upcoming examination, or to oral information delivered by each patient's doctor. Evaluation of quality of information was rated on scales between 0 (none received) and 5 (excellent). The analysis of outcome variables was performed on the basis of intention to treat-analysis. Multivariate analysis of predictors of information scores was performed by linear regression analysis. RESULTS: Of 718 eligible patients 577 (80%) returned their questionnaire. Patients who received written leaflets (N = 278) rated the quality of information they received higher than those informed verbally (N = 299), for all 8 quality-of-information items. Differences were significant regarding information about the risks of the procedure (3.24 versus 2.26, p &lt; 0.001), how to prepare for the procedure (3.56 versus 3.23, p = 0.036), what to expect after the procedure (2.99 versus 2.59, p &lt; 0.001), and the 8 quality-of-information items (3.35 versus 3.02, p = 0.002). The two groups reported similar levels of anxiety before procedure (p = 0.66), pain during procedure (p = 0.20), tolerability throughout the procedure (p = 0.76), problems after the procedure (p = 0.22), and overall rating of the procedure between poor and excellent (p = 0.82). CONCLUSION: Written information led to more favourable assessments of the quality of information and had no impact on patient anxiety nor on the overall assessment of the endoscopy. Because structured and comprehensive written information is perceived as beneficial by patients, gastroenterologists should clearly explain to their patients the risks, benefits and alternatives of endoscopic procedures. Trial registration: Current Controlled trial number: ISRCTN34382782

    Measurement of Longitudinal Spin Transfer to Lambda Hyperons in Deep-Inelastic Lepton Scattering

    Get PDF
    Spin transfer in deep-inelastic Lambda electroproduction has been studied with the HERMES detector using the 27.6 GeV polarized positron beam in the HERA storage ring. For an average fractional energy transfer = 0.45, the longitudinal spin transfer from the virtual photon to the Lambda has been extracted. The spin transfer along the Lambda momentum direction is found to be 0.11 +/- 0.17 (stat) +/- 0.03 (sys); similar values are found for other possible choices for the longitudinal spin direction of the Lambda. This result is the most precise value obtained to date from deep-inelastic scattering with charged lepton beams, and is sensitive to polarized up quark fragmentation to hyperon states. The experimental result is found to be in general agreement with various models of the Lambda spin content, and is consistent with the assumption of helicity conservation in the fragmentation process.Comment: 8 pages, 3 figures; new version has an expanded discussion and small format change

    Double parton interactions in photon+3 jet events in ppbar collisions sqrt{s}=1.96 TeV

    Get PDF
    We have used a sample of photon+3 jets events collected by the D0 experiment with an integrated luminosity of about 1 fb^-1 to determine the fraction of events with double parton scattering (f_DP) in a single ppbar collision at sqrt{s}=1.96 TeV. The DP fraction and effective cross section (sigma_eff), a process-independent scale parameter related to the parton density inside the nucleon, are measured in three intervals of the second (ordered in pT) jet transverse momentum pT_jet2 within the range 15 < pT_jet2 < 30 GeV. In this range, f_DP varies between 0.23 < f_DP < 0.47, while sigma_eff has the average value sigma_eff_ave = 16.4 +- 0.3(stat) +- 2.3(syst) mb.Comment: 15 pages, 13 figure

    Observation of a Coherence Length Effect in Exclusive Rho^0 Electroproduction

    Get PDF
    Exclusive incoherent electroproduction of the rho^0(770) meson from 1H, 2H, 3He, and 14N targets has been studied by the HERMES experiment at squared four-momentum transfer Q**2>0.4 GeV**2 and positron energy loss nu from 9 to 20 GeV. The ratio of the 14N to 1H cross sections per nucleon, known as the nuclear transparency, was found to decrease with increasing coherence length of quark-antiquark fluctuations of the virtual photon. The data provide clear evidence of the interaction of the quark- antiquark fluctuations with the nuclear medium.Comment: RevTeX, 5 pages, 3 figure

    Dependence of the ttˉt\bar{t} production cross section on the transverse momentum of the top quark

    Get PDF
    We present a measurement of the differential cross section for ttˉt\bar{t} events produced in ppˉp\bar{p} collisions at s=1.96\sqrt{s}=1.96 TeV as a function of the transverse momentum (pTp_T) of the top quark. The selected events contain a high-pTp_T lepton (\ell), four or more jets, and a large imbalance in pTp_T, and correspond to 1 fb1{}^{-1} of integrated luminosity recorded with the D0 detector. Each event must have at least one candidate for a bb jet. Objects in the event are associated through a constrained kinematic fit to the ttˉWbWbˉνbqqˉbˉt\bar{t}\to WbW\bar{b} \to \ell\nu b q\bar{q}'\bar{b} process. Results from next-to-leading-order perturbative QCD calculations agree with the measured differential cross section. Comparisons are also provided to predictions from Monte Carlo event generators using QCD calculations at different levels of precision.Comment: 8 pages, 6 figures, 4 tables, updated to reflect the published versio
    corecore