488 research outputs found
Spontaneous Rotation of a Toric Implantable Collamer Lens
We present a case of toric implantable collamer lens (TICL) spontaneous rotation in a patient with myopic astigmatism. A 23-year-old female underwent TICL implantation. Preoperative uncorrected visual acuity (UCVA) was 20/800 and 20/1200, respectively, with â7.75 â4.25 Ă 0° and â8.25 â5.25 Ă 180°. The left eye achieved an UCVA of 20/30. After 3 months of successful implantation of TICL in the left eye, the patient presented with a sudden decrease in visual acuity in the left eye. UCVA was 20/100 with a refraction of +2.50 â4.50 Ă 165°. We observed the toric marks with a 30° rotation from the original position and decided to reposition the TICL, obtaining a final UCVA of 20/25, which remained stable at 6 months' follow-up. TICL can present a considerable rotation that compromises visual acuity. The relocation of TICL is a safe and effective procedure to recover visual acuity due to significant spontaneous TICL rotation
Plasma lensing of a laser wakefield accelerated electron bunch
We report on the first all-optical demonstration of
plasma lensing using laser wakefield accelerated
elec-trons in a two-stage setup. The LWFA electron
bunch was focused by a second plasma stage without
any ex-ternal fields applied..
Confluence and Convergence in Probabilistically Terminating Reduction Systems
Convergence of an abstract reduction system (ARS) is the property that any
derivation from an initial state will end in the same final state, a.k.a.
normal form. We generalize this for probabilistic ARS as almost-sure
convergence, meaning that the normal form is reached with probability one, even
if diverging derivations may exist. We show and exemplify properties that can
be used for proving almost-sure convergence of probabilistic ARS, generalizing
known results from ARS.Comment: Pre-proceedings paper presented at the 27th International Symposium
on Logic-Based Program Synthesis and Transformation (LOPSTR 2017), Namur,
Belgium, 10-12 October 2017 (arXiv:1708.07854
Demonstration of passive plasma lensing of a laser wakefield accelerated electron bunch
We report on the first demonstration of passive all-optical plasma lensing using a two-stage setup. An intense femtosecond laser accelerates electrons in a laser wakefield accelerator (LWFA) to 100Â MeV over millimeter length scales. By adding a second gas target behind the initial LWFA stage we introduce a robust and independently tunable plasma lens. We observe a density dependent reduction of the LWFA electron beam divergence from an initial value of 2.3Â mrad, down to 1.4Â mrad (rms), when the plasma lens is in operation. Such a plasma lens provides a simple and compact approach for divergence reduction well matched to the mm-scale length of the LWFA accelerator. The focusing forces are provided solely by the plasma and driven by the bunch itself only, making this a highly useful and conceptually new approach to electron beam focusing. Possible applications of this lens are not limited to laser plasma accelerators. Since no active driver is needed the passive plasma lens is also suited for high repetition rate focusing of electron bunches. Its understanding is also required for modeling the evolution of the driving particle bunch in particle driven wake field acceleration
Dosimetric precision of an ion beam tracking system
<p>Abstract</p> <p>Background</p> <p>Scanned ion beam therapy of intra-fractionally moving tumors requires motion mitigation. GSI proposed beam tracking and performed several experimental studies to analyse the dosimetric precision of the system for scanned carbon beams.</p> <p>Methods</p> <p>A beam tracking system has been developed and integrated in the scanned carbon ion beam therapy unit at GSI. The system adapts pencil beam positions and beam energy according to target motion.</p> <p>Motion compensation performance of the beam tracking system was assessed by measurements with radiographic films, a range telescope, a 3D array of 24 ionization chambers, and cell samples for biological dosimetry. Measurements were performed for stationary detectors and moving detectors using the beam tracking system.</p> <p>Results</p> <p>All detector systems showed comparable data for a moving setup when using beam tracking and the corresponding stationary setup. Within the target volume the mean relative differences of ionization chamber measurements were 0.3% (1.5% standard deviation, 3.7% maximum). Film responses demonstrated preserved lateral dose gradients. Measurements with the range telescope showed agreement of Bragg peak depth under motion induced range variations. Cell survival experiments showed a mean relative difference of -5% (-3%) between measurements and calculations within the target volume for beam tracking (stationary) measurements.</p> <p>Conclusions</p> <p>The beam tracking system has been successfully integrated. Full functionality has been validated dosimetrically in experiments with several detector types including biological cell systems.</p
Laser-plasma-based space radiation reproduction in the laboratory
Space radiation is a great danger to electronics and astronauts onboard space vessels. The spectral flux of space electrons, protons and ions for example in the radiation belts is inherently broadband, but this is a feature hard to mimic with conventional radiation sources. Using laser-plasma-accelerators, we reproduced relativistic, broadband radiation belt flux in the laboratory, and used this man-made space radiation to test the radiation hardness of space electronics. Such close mimicking of space radiation in the lab builds on the inherent ability of laser-plasma-accelerators to directly produce broadband Maxwellian-type particle flux, akin to conditions in space. In combination with the established sources, utilisation of the growing number of ever more potent laser-plasma-accelerator facilities worldwide as complementary space radiation sources can help alleviate the shortage of available beamtime and may allow for development of advanced test procedures, paving the way towards higher reliability of space missions
All-optical density downramp injection in electron-driven plasma wakefield accelerators
Injection of well-defined, high-quality electron populations into plasma waves is a key challenge of plasma wakefield accelerators. Here, we report on the first experimental demonstration of plasma density downramp injection in an electron-driven plasma wakefield accelerator, which can be controlled and tuned in all-optical fashion by mJ-level laser pulses. The laser pulse is directed across the path of the plasma wave before its arrival, where it generates a local plasma density spike in addition to the background plasma by tunnelling ionization of a high ionization threshold gas component. This density spike distorts the plasma wave during the density downramp, causing plasma electrons to be injected into the plasma wave. By tuning the laser pulse energy and shape, highly flexible plasma density spike profiles can be designed, enabling dark current free, versatile production of high-quality electron beams. This in turn permits creation of unique injected beam configurations such as counter-oscillating twin beamlets
Comparability of Plasma Iohexol Clearance Across Population-Based Cohorts.
To access publisher's full text version of this article, please click on the hyperlink in Additional Links field or click on the hyperlink at the top of the page marked DownloadRationale & objective: Glomerular filtration rate (GFR) estimation based on creatinine or cystatin C level is currently the standard method for assessing GFR in epidemiologic research and clinical trials despite several important and well-known limitations. Plasma iohexol clearance has been proposed as an inexpensive method for measuring GFR that could replace estimated GFR in many research projects. However, lack of standardization for iohexol assays and the use of different protocols such as single- and multiple-sample methods could potentially hamper comparisons across studies. We compared iohexol assays and GFR measurement protocols in 3 population-based European cohorts.
Study design: Cross-sectional investigation.
Setting & participants: Participants in the Age, Gene/Environment Susceptibility-Kidney Study (AGES-Kidney; n=805), the Berlin Initiative Study (BIS, n=570), and the Renal Iohexol Clearance Survey Follow-up Study (RENIS-FU; n=1,324).
Tests compared: High-performance liquid chromatography analyses of iohexol. Plasma iohexol clearance calculated using single- versus multiple-sample protocols.
Outcomes: Measures of agreement between methods.
Results: Frozen samples from the 3 studies were obtained and iohexol concentrations were remeasured in the laboratory at the University Hospital of North Norway. Lin's concordance correlation coefficient Ï was>0.96 and Cb (accuracy) was>0.99 for remeasured versus original serum iohexol concentrations in all 3 cohorts, and Passing-Bablok regression did not find differences between measurements, except for a slope of 1.025 (95% CI, 1.006-1.046) for the log-transformed AGES-Kidney measurements. The multiple-sample iohexol clearance measurements in AGES-Kidney and BIS were compared with single-sample GFRs derived from the same iohexol measurements. Mean bias for multiple-sample relative to single-sample GFRs in AGES-Kidney and BIS were-0.25 and-0.15mL/min, and 99% and 97% of absolute differences were within 10% of the multiple-sample result, respectively.
Limitations: Lack of comparison with an independent gold-standard method.
Conclusions: Agreement between the iohexol assays and clearance protocols in the 3 investigated cohorts was substantial. Our findings indicate that plasma iohexol clearance measurements can be compared across these studies.
Keywords: Renal clearance; accuracy; agreement; concordance correlation; glomerular filtration rate (GFR); iohexol; kidney function tests; measured GFR; measurement error; multiple-sample; single-sample.United States Department of Health & Human Services
National Institutes of Health (NIH) - USA
National Institute on Aging, United States
Hjartavernd, Iceland (Icelandic Heart Association)
Icelandic Parliament (Althingi)
KfH-Foundation of Preventive Medicine, Germany
Dr. Werner Jackstadt Foundation, Germany
Northern Norway Regional Health Authority
Boehringer Ingelhei
Deep Annotation of Populus trichocarpa microRNAs from Diverse Tissue Sets
Populus trichocarpa is an important woody model organism whose entire genome has been sequenced. This resource has facilitated the annotation of microRNAs (miRNAs), which are short non-coding RNAs with critical regulatory functions. However, despite their developmental importance, P. trichocarpa miRNAs have yet to be annotated from numerous important tissues. Here we significantly expand the breadth of tissue sampling and sequencing depth for miRNA annotation in P. trichocarpa using high-throughput smallRNA (sRNA) sequencing. miRNA annotation was performed using three individual next-generation sRNA sequencing runs from separate leaves, xylem, and mechanically treated xylem, as well as a fourth run using a pooled sample containing vegetative apices, male flowers, female flowers, female apical buds, and male apical and lateral buds. A total of 276 miRNAs were identified from these datasets, including 155 previously unannotated miRNAs, most of which are P. trichocarpa specific. Importantly, we identified several xylem-enriched miRNAs predicted to target genes known to be important in secondary growth, including the critical reaction wood enzyme xyloglucan endo-transglycosylase/hydrolase and vascular-related transcription factors. This study provides a thorough genome-wide annotation of miRNAs in P. trichocarpa through deep sRNA sequencing from diverse tissue sets. Our data significantly expands the P. trichocarpa miRNA repertoire, which will facilitate a broad range of research in this major model system
- âŠ