285 research outputs found

    MODULATION OF AUTONOMIC NERVOUS SYSTEM ASSESSED THROUGH HEART RATE VARIABILITY BY INTEGRATED AMRITA MEDITATION TECHNIQUE IN TYPE 2 DIABETIC SUBJECTS – A PILOT STUDY

    Get PDF
    Objective: This study aims in understanding the effects of Integrated Amrita Meditation (IAM), a type of mindfulness meditation, on the autonomic balance of type 2 diabetic patients through assessment of heart rate variability (HRV). Methods: After the initial screening of 30 type 2 diabetic subjects, 10 type 2 diabetic subjects between the age group of 30 and 65 years were randomized into two groups, diabetic test (n=5) and diabetic control group (n=5). Diabetic test group practiced IAM technique under the guidance of a trained practitioner. Both the groups continued the same dietary pattern and medications during the 6-month study period. HRV was taken for all subjects at baseline and after 6 months. In our study, we have focused on the power spectral analysis of HRV which include normalized units of high frequency (nHF), low frequency (nLF), and low frequency-high frequency ratio (LF/HF ratio). Results: Mean percentage change in nHF, nLF, and LFHF ratio showed significant changes in between-group comparison (p<0.05). Normalized units of HF increased (p=0.049) while LF (p=0.036) and LFHF ratio (p=0.024) decreased significantly within test group after 6 months of IAM practice suggesting the potential of IAM in improving the parasympathetic tone, thereby tuning the mind and body to calm down during stress. Conclusion: Our study has shown demonstrable improvement in autonomic function which reflects reduced stress after the practice of IAM in diabetic patients

    30 inch Roll-Based Production of High-Quality Graphene Films for Flexible Transparent Electrodes

    Full text link
    We report that 30-inch scale multiple roll-to-roll transfer and wet chemical doping considerably enhance the electrical properties of the graphene films grown on roll-type Cu substrates by chemical vapor deposition. The resulting graphene films shows a sheet resistance as low as ~30 Ohm/sq at ~90 % transparency which is superior to commercial transparent electrodes such as indium tin oxides (ITO). The monolayer of graphene shows sheet resistances as low as ~125 Ohm/sq with 97.4% optical transmittance and half-integer quantum Hall effect, indicating the high-quality of these graphene films. As a practical application, we also fabricated a touch screen panel device based on the graphene transparent electrodes, showing extraordinary mechanical and electrical performances

    Anaesthesiological strategies in elective craniotomy: randomized, equivalence, open trial – The NeuroMorfeo trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Many studies have attempted to determine the <it>"best" </it>anaesthetic technique for neurosurgical procedures in patients without intracranial hypertension. So far, no study comparing intravenous (IA) with volatile-based neuroanaesthesia (VA) has been able to demonstrate major outcome differences nor a superiority of one of the two strategies in patients undergoing elective supratentorial neurosurgery. Therefore, current practice varies and includes the use of either volatile or intravenous anaesthetics in addition to narcotics. Actually the choice of the anaestesiological strategy depends only on the anaesthetists' preferences or institutional policies.</p> <p>This trial, named NeuroMorfeo, aims to assess the equivalence between volatile and intravenous anaesthetics for neurosurgical procedures.</p> <p>Methods/Design</p> <p>NeuroMorfeo is a multicenter, randomized, open label, controlled trial, based on an equivalence design. Patients aged between 18 and 75 years, scheduled for elective craniotomy for supratentorial lesion without signs of intracranial hypertension, in good physical state (ASA I-III) and Glasgow Coma Scale (GCS) equal to 15, are randomly assigned to one of three anaesthesiological strategies (two VA arms, sevoflurane + fentanyl or sevoflurane + remifentanil, and one IA, propofol + remifentanil). The equivalence between intravenous and volatile-based neuroanaesthesia will be evaluated by comparing the intervals required to reach, after anaesthesia discontinuation, a modified Aldrete score ≥ 9 (primary end-point). Two statistical comparisons have been planned:</p> <p>1) sevoflurane + fentanyl vs. propofol + remifentanil;</p> <p>2) sevoflurane + remifentanil vs. propofol + remifentanil.</p> <p>Secondary end-points include: an assessment of neurovegetative stress based on (a) measurement of urinary catecholamines and plasma and urinary cortisol and (b) estimate of sympathetic/parasympathetic balance by power spectrum analyses of electrocardiographic tracings recorded during anaesthesia; intraoperative adverse events; evaluation of surgical field; postoperative adverse events; patient's satisfaction and analysis of costs.</p> <p>411 patients will be recruited in 14 Italian centers during an 18-month period.</p> <p>Discussion</p> <p>We presented the development phase of this anaesthesiological on-going trial. The recruitment started December 4<sup>th</sup>, 2007 and up to 4<sup>th</sup>, December 2008, 314 patients have been enrolled.</p

    Two independent proteomic approaches provide a comprehensive analysis of the synovial fluid proteome response to Autologous Chondrocyte Implantation

    Get PDF
    Background: Autologous chondrocyte implantation (ACI) has a failure rate of approximately 20%, but it is yet to be fully understood why. Biomarkers are needed that can pre-operatively predict in which patients it is likely to fail, so that alternative or individualised therapies can be offered. We previously used label-free quantitation (LF) with a dynamic range compression proteomic approach to assess the synovial fluid (SF) of ACI responders and non-responders. However, we were able to identify only a few differentially abundant proteins at baseline. In the present study, we built upon these previous findings by assessing higher-abundance proteins within this SF, providing a more global proteomic analysis on the basis of which more of the biology underlying ACI success or failure can be understood. Methods: Isobaric tagging for relative and absolute quantitation (iTRAQ) proteomic analysis was used to assess SF from ACI responders (mean Lysholm improvement of 33; n = 14) and non-responders (mean Lysholm decrease of 14; n = 13) at the two stages of surgery (cartilage harvest and chondrocyte implantation). Differentially abundant proteins in iTRAQ and combined iTRAQ and LF datasets were investigated using pathway and network analyses. Results: iTRAQ proteomic analysis confirmed our previous finding that there is a marked proteomic shift in response to cartilage harvest (70 and 54 proteins demonstrating ≥ 2.0-fold change and p < 0.05 between stages I and II in responders and non-responders, respectively). Further, it highlighted 28 proteins that were differentially abundant between responders and non-responders to ACI, which were not found in the LF study, 16 of which were altered at baseline. The differential expression of two proteins (complement C1s subcomponent and matrix metalloproteinase 3) was confirmed biochemically. Combination of the iTRAQ and LF proteomic datasets generated in-depth SF proteome information that was used to generate interactome networks representing ACI success or failure. Functional pathways that are dysregulated in ACI non-responders were identified, including acute-phase response signalling. Conclusions: Several candidate biomarkers for baseline prediction of ACI outcome were identified. A holistic overview of the SF proteome in responders and non-responders to ACI  has been profiled, providing a better understanding of the biological pathways underlying clinical outcome, particularly the differential response to cartilage harvest in non-responders

    Electrodeposition and characterisation of CdS thin films using thiourea precursor for application in solar cells

    Get PDF
    CdS thin films have been successfully electrodeposited on glass/FTO substrates using acidic and aqueous solution of CdCl2.xH2O and thiourea (SC(NH2)2). The electrodeposition of CdS thin films were carried out potentiostatically using a 2-electrode system. The prepared films were characterised using X-ray diffraction (XRD), Raman spectroscopy, Scanning electron microscopy (SEM), Atomic force microscopy (AFM), Photoelectrochemical (PEC) cell measurements, Electrical resistivity measurements and UV-Vis spectrophotometry to study their structural, compositional, morphological, electrical and optical properties, respectively. The structural studies show that the as-deposited and annealed CdS layers are polycrystalline with hexagonal crystal structure and preferentially oriented along (200) planes. The optical studies indicate that the ED-CdS layers have direct bandgaps in the range (2.53-2.58) eV for the as-deposited and (2.42-2.48) eV after annealing at 400oC for 20 minutes in air. The morphological studies show the good coverage of the FTO surface by the CdS grains. The average grain sizes for the as-deposited and annealed layers were in the range (60-225) nm. These grains or clusters are made out of smaller nano crystallites with the sizes in the range ~(11-33) nm. The electrical resistivity shows reduction as thickness increases. The resistivity values for the as-deposited and annealed layers were in the range (0.82-4.92)×105 Ωcm. The optimum growth voltage for the CdS thin films was found to be at the cathodic potential of 797 mV with respect to the graphite anode. No visible precipitations of elemental S or CdS particles were observed in the deposition electrolyte showing a stable bath using thiourea during the growth

    Giant spin Hall effect in graphene grown by chemical vapour deposition

    Get PDF
    Advances in large-area graphene synthesis via chemical vapour deposition on metals like copper were instrumental in the demonstration of graphene-based novel, wafer-scale electronic circuits and proof-of-concept applications such as flexible touch panels. Here, we show that graphene grown by chemical vapour deposition on copper is equally promising for spintronics applications. In contrast to natural graphene, our experiments demonstrate that chemically synthesized graphene has a strong spin-orbit coupling as high as 20 meV giving rise to a giant spin Hall effect. The exceptionally large spin Hall angle ∼0.2 provides an important step towards graphene-based spintronics devices within existing complementary metal-oxide-semiconductor technology. Our microscopic model shows that unavoidable residual copper adatom clusters act as local spin-orbit scatterers and, in the resonant scattering limit, induce transverse spin currents with enhanced skew-scattering contribution. Our findings are confirmed independently by introducing metallic adatoms-copper, silver and gold on exfoliated graphene samples

    Observing the temperature dependent transition of the GP2 peptide using terahertz spectroscopy

    Get PDF
    The GP2 peptide is derived from the Human Epidermal growth factor Receptor 2 (HER2/nue), a marker protein for breast cancer present in saliva. In this paper we study the temperature dependent behavior of hydrated GP2 at terahertz frequencies and find that the peptide undergoes a dynamic transition between 200 and 220 K. By fitting suitable molecular models to the frequency response we determine the molecular processes involved above and below the transition temperature (TD). In particular, we show that below TD the dynamic transition is dominated by a simple harmonic vibration with a slow and temperature dependent relaxation time constant and that above TD, the dynamic behavior is governed by two oscillators, one of which has a fast and temperature independent relaxation time constant and the other of which is a heavily damped oscillator with a slow and temperature dependent time constant. Furthermore a red shifting of the characteristic frequency of the damped oscillator was observed, confirming the presence of a non-harmonic vibration potential. Our measurements and modeling of GP2 highlight the unique capabilities of THz spectroscopy for protein characterization.Yiwen Sun, Zexuan Zhu, Siping Chen, Jega Balakrishnan, Derek Abbott, Anil T. Ahuja and Emma Pickwell-MacPherso

    Combination Therapy Is Superior to Sequential Monotherapy for the Initial Treatment of Hypertension:A Double-Blind Randomized Controlled Trial

    Get PDF
    Background: Guidelines for hypertension vary in their preference for initial combination therapy or initial monotherapy, stratified by patient profile; therefore, we compared the efficacy and tolerability of these approaches. Methods and Results: We performed a 1‐year, double‐blind, randomized controlled trial in 605 untreated patients aged 18 to 79 years with systolic blood pressure (BP) ≥150 mm Hg or diastolic BP ≥95 mm Hg. In phase 1 (weeks 0–16), patients were randomly assigned to initial monotherapy (losartan 50–100 mg or hydrochlorothiazide 12.5–25 mg crossing over at 8 weeks), or initial combination (losartan 50–100 mg plus hydrochlorothiazide 12.5–25 mg). In phase 2 (weeks 17–32), all patients received losartan 100 mg and hydrochlorothiazide 12.5 to 25 mg. In phase 3 (weeks 33–52), amlodipine with or without doxazosin could be added to achieve target BP. Hierarchical primary outcomes were the difference from baseline in home systolic BP, averaged over phases 1 and 2 and, if significant, at 32 weeks. Secondary outcomes included adverse events, and difference in home systolic BP responses between tertiles of plasma renin. Home systolic BP after initial monotherapy fell 4.9 mm Hg (range: 3.7–6.0 mm Hg) less over 32 weeks (P&lt;0.001) than after initial combination but caught up at 32 weeks (difference 1.2 mm Hg [range: −0.4 to 2.8 mm Hg], P=0.13). In phase 1, home systolic BP response to each monotherapy differed substantially between renin tertiles, whereas response to combination therapy was uniform and at least 5 mm Hg more than to monotherapy. There were no differences in withdrawals due to adverse events. Conclusions: Initial combination therapy can be recommended for patients with BP &gt;150/95 mm Hg. Clinical Trial Registration URL: http://www.ClinicalTrials.gov. Unique identifier: NCT00994617
    corecore