14 research outputs found

    Role of Endoscopic Ultrasound in the Evaluation of Pancreatic Cystic Neoplasms: A Concise Review

    No full text
    Pancreatic cystic lesions are being discovered as incidental lesions during cross-sectional imaging studies of the abdomen with increasing frequency. Endoscopic ultrasound is an important diagnostic modality for managing pancreatic cystic lesions. There are various types of pancreatic cystic lesions, from benign to malignant. Endoscopic ultrasound has a multifactorial role in delineating the morphology of pancreatic cystic lesions, ranging from fluid and tissue acquisition for analysis—fine needle aspiration and through-the-needle biopsy, respectively—to advanced imaging techniques, such as contrast-harmonic mode endoscopic ultrasound and EUS-guided needle-based confocal laser endomicroscopy. In this review, we will summarize and provide an update on the specific role of EUS in the management of pancreatic cystic lesions

    Analysis of Reported Adverse Events Related to Single Use Duodenoscopes and Duodenoscopes with Detachable Endcaps

    No full text
    Background: Single use duodenoscopes and duodenoscopes with disposable/detachable caps emerged in the market to mitigate endoscopic retrograde cholangiopancreatography- related risk of infections. We aim to investigate post Food and Drug Administration (FDA) approval adverse events associated with these devices. Methods: We analyzed post-marketing surveillance data from the FDA Manufacturer and User Facility Device Experience (MAUDE) database from July 2018 to June 2021. Results: One hundred and ninety-five reports comprised 206 device issues and 118 patient complications were identified from July 2018 through June 2021. Most device issues related to the single use duodenoscope were due to optical problems (7 reports). Other reported device issues included difficulty in advancing the scope (2 reports), fluid leak (2 reports), and use of device problems (2 reports). Among the duodenoscopes with detachable endcaps, most device issues related to bacterial contamination (52 reports), followed by issues with device use (31 reports), detachment /separation of the device (25 reports), and crack/dent in device material (16 reports). Overall, the most reported patient adverse events were tissue injury (63 reports), perforation (8 reports), and bleeding (7 reports). Ninety reports of microbial contamination of duodenoscopes were identified of which Pseudomonas Aeruginosa was most common. Conclusion: Findings from the MAUDE database highlight patient and device complications that endoscopists should be aware of in using single-use duodenoscopes and duodenoscopes with detachable caps. While these devices mitigate infection transmission risk, they are associated with additional device-associated adverse events
    corecore