43 research outputs found

    Giant Fibrolipoma in the Distal Limb of a Cow

    Get PDF
    Background: Lipomas are adipocytic tumors of slow and expansive growth. They can be classified into several subtypes depending on the tissue present next to the neoplastic adipocytes. One of such subtypes is the fibrolipoma, which is formed by well-differentiated adipocytes and fibrous connective tissue. This neoplasm has been little described in cattle, and rare reports present the treatment and resolution of the case. Thus, the dissemination of cases of fibrolipomas in cattle is essential to help veterinarians diagnose this neoplasm. The present report describes a case of fibrolipoma in the distal pelvic limb of a cow successfully treated by surgical excision. Case: A 4-year-old 3/4 Girolando cow from the municipality of Vazante-MG, Brazil, was treated on the farm. According to the owner, the animal had been showing tumoral growth in the left pelvic limb over the period of 1 year and 3 months. The tumor involved the entire left metatarsus and was 40 x 37 cm, without ulcerations and painless on palpation. A neoplasm was suspected and surgical excision was the chosen approach. The cow was sedated, positioned and restrained in right lateral recumbency for surgery. The operative field was prepared and a subcutaneous locoregional ring block was performed dorsally to the tumor. The tumor mass was excised with a safety margin of 1 cm. After removal, the mass was found to weigh 10.4 kg and to be yellowish-white upon sectioning. Due to the distance between the edges of the surgical wound, skin suture could not be performed. Thus, second-intention healing and wound protection with bandages were the choice of management. In the postoperative period, the adopted treatment consisted of antibiotic therapy with benzathine penicillin, analgesia with non-steroidal anti-inflammatory drugs, daily dressings and wound protection with bandages. The animal did not show postoperative complications and, over 8 months of monitoring after surgery, there was no recurrence of the neoplasm and the cow was in productive activity. Tumor fragments were fixed in 10%buffered formalinand sent for histopathological examination, which revealed a neoplasm of mesenchymal cells in the subcutaneous adipose tissue supported by dense fibrovascular stroma with solid arrangement. A large amount of dense connective tissue was found among the neoplastic cells. In view of these findings, the diagnosis of fibrolipoma was established.Discussion: Fibrolipoma is a benign neoplasm little described in the veterinary literature, especially in cattle, with only 3 cases reported. To the knowledge of the authors, this is the first report of this neoplasm in the distal limb of cattle. Fibrolipomas are a rare type of lipoma formed by well-differentiated lipocytes and fibrous tissue. The fibrolipoma described in this report was 40 cm in diameter and weighed 10.4 kg, so it can be classified as a type of giant lipoma, as it was more than 10 cm in diameter and more than 1 kg in weight. In the present report and in others in the medical literature, surgical removal of the fibrolipoma resulted in complete recovery of the patient without postoperative complications. Surgical excision is the treatment of choice in these cases and usually promotes healing. However, surgery must be performed early and the neoplasm must be completely removed. The histological characteristics of the fibrolipoma in this case are similar to those found in other cases in cattle and corroborate the choice for surgical treatment and maintenance of the animal in the herd. Although rare, fibrolipomas should be included in the differential diagnosis of tumors of slow and expansive growth in cattle.Keywords: bovine, adipose tissue, lipoma, neoplasia, surgery.Descritores: bovino, cirurgia, tecido adiposo, lipoma, neoplasia.Título: Fibrolipoma gigante no membro distal de uma vaca

    Loss of postprandial insulin clearance control by Insulin-degrading enzyme drives dysmetabolism traits

    Get PDF
    Systemic insulin availability is determined by a balance between beta-cell secretion capacity and insulin clearance (IC). Insulin-degrading enzyme (IDE) is involved in the intracellular mechanisms underlying IC. The liver is a major player in IC control yet the role of hepatic IDE in glucose and lipid homeostasis remains unexplored. We hypothesized that IDE governs postprandial IC and hepatic IDE dysfunction amplifies dysmetabolic responses and prediabetes traits such as hepatic steatosis. In a European/Portuguese population-based cohort, IDE SNPs were strongly associated with postprandial IC in normoglycemic men but to a considerably lesser extent in women or in subjects with prediabetes. Liver-specific knockout-mice (LS-IDE KO) under normal chow diet (NCD), showed reduced postprandial IC with glucose intolerance and under high fat diet (HFD) were more susceptible to hepatic steatosis than control mice. This suggests that regulation of IC by IDE contributes to liver metabolic resilience. In agreement, LS-IDE KO hepatocytes revealed reduction of Glut2 expression levels with consequent impairment of glucose uptake and upregulation of CD36, a major hepatic free fatty acid transporter. Together these findings provide strong evidence that dysfunctional IC due to abnormal IDE regulation directly impairs postprandial hepatic glucose disposal and increases susceptibility to dysmetabolic conditions in the setting of Western diet/lifestyle.publishe

    Livro Verde dos Montados

    Get PDF
    O Livro Verde dos Montados apresenta diversos objectivos que se interligam: Em primeiro lugar, o Livro Verde pretende reunir e sistematizar, de uma forma simples e acessível ao público, o conhecimento produzido em Portugal pelos investigadores e técnicos de várias instituições de investigação ou de gestão que estudam o Montado. Assume-se como uma oportunidade de caracterizar o sistema tendo em conta as suas várias dimensões, identificando as principais ameaças à sua preservação assim como os caminhos que podem ajudar à sua sustentabilidade. Não sendo um documento científico, baseia-se no conhecimento científico e pretende constituir a base para uma plataforma de organização, tanto dos investigadores como do conhecimento científico actualmente produzido em Portugal sobre o Montado.Em segundo lugar, o Livro Verde deverá contribuir para um entendimento partilhado do que é o Montado, por parte do público, de técnicos e de especialistas, conduzindo a uma classificação mais clara do que pode ser considerado Montado e de quais os tipos distintos de Montados que podem ser identificados. Em terceiro lugar, o Livro Verde estabelece as bases para uma estratégia coordenada de disponibilização de informação sobre o sistema Montado, visando o seu conhecimento, apreciação e valorização pela sociedade portuguesa no seu conjunto. Deste modo, o Livro Verde poderá constituir um instrumento congregador e inspirador para a realização de acções de sensibilização e informação sobre o Montado. Em quarto lugar, pretende-se que o Livro Verde contribua para um maior reconhecimento e valorização do Montado como sistema, a nível do desenho das políticas nacionais por parte dos vários sectores envolvidos.Finalmente, o Livro Verde constituirá um documento parceiro do Livro Verde das Dehesas, produzido em Espanha em 2010, de forma a reforçar o reconhecimento e a devida valorização destes sistemas silvo-pastoris no desenho das estratégias e políticas relevantes pelas instituições europeias. Em suma, os autores pretendem que o Livro Verde dos Montados se afirme como o primeiro passo para uma efectiva definição e implementação de uma estratégia nacional para os Montados

    Mudança dos critérios Qualis!

    Get PDF

    Statement of Second Brazilian Congress of Mechanical Ventilarion : part I

    Get PDF
    Resumo não disponíve

    Diretrizes Brasileiras de Medidas da Pressão Arterial Dentro e Fora do Consultório – 2023

    Get PDF
    Hypertension is one of the primary modifiable risk factors for morbidity and mortality worldwide, being a major risk factor for coronary artery disease, stroke, and kidney failure. Furthermore, it is highly prevalent, affecting more than one-third of the global population. Blood pressure measurement is a MANDATORY procedure in any medical care setting and is carried out by various healthcare professionals. However, it is still commonly performed without the necessary technical care. Since the diagnosis relies on blood pressure measurement, it is clear how important it is to handle the techniques, methods, and equipment used in its execution with care. It should be emphasized that once the diagnosis is made, all short-term, medium-term, and long-term investigations and treatments are based on the results of blood pressure measurement. Therefore, improper techniques and/or equipment can lead to incorrect diagnoses, either underestimating or overestimating values, resulting in inappropriate actions and significant health and economic losses for individuals and nations. Once the correct diagnosis is made, as knowledge of the importance of proper treatment advances, with the adoption of more detailed normal values and careful treatment objectives towards achieving stricter blood pressure goals, the importance of precision in blood pressure measurement is also reinforced. Blood pressure measurement (described below) is usually performed using the traditional method, the so-called casual or office measurement. Over time, alternatives have been added to it, through the use of semi-automatic or automatic devices by the patients themselves, in waiting rooms or outside the office, in their own homes, or in public spaces. A step further was taken with the use of semi-automatic devices equipped with memory that allow sequential measurements outside the office (ABPM; or HBPM) and other automatic devices that allow programmed measurements over longer periods (HBPM). Some aspects of blood pressure measurement can interfere with obtaining reliable results and, consequently, cause harm in decision-making. These include the importance of using average values, the variation in blood pressure during the day, and short-term variability. These aspects have encouraged the performance of a greater number of measurements in various situations, and different guidelines have advocated the use of equipment that promotes these actions. Devices that perform HBPM or ABPM, which, in addition to allowing greater precision, when used together, detect white coat hypertension (WCH), masked hypertension (MH), sleep blood pressure alterations, and resistant hypertension (RHT) (defined in Chapter 2 of this guideline), are gaining more and more importance. Taking these details into account, we must emphasize that information related to diagnosis, classification, and goal setting is still based on office blood pressure measurement, and for this reason, all attention must be given to the proper execution of this procedure.La hipertensión arterial (HTA) es uno de los principales factores de riesgo modificables para la morbilidad y mortalidad en todo el mundo, siendo uno de los mayores factores de riesgo para la enfermedad de las arterias coronarias, el accidente cerebrovascular (ACV) y la insuficiencia renal. Además, es altamente prevalente y afecta a más de un tercio de la población mundial. La medición de la presión arterial (PA) es un procedimiento OBLIGATORIO en cualquier atención médica o realizado por diferentes profesionales de la salud. Sin embargo, todavía se realiza comúnmente sin los cuidados técnicos necesarios. Dado que el diagnóstico se basa en la medición de la PA, es claro el cuidado que debe haber con las técnicas, los métodos y los equipos utilizados en su realización. Debemos enfatizar que una vez realizado el diagnóstico, todas las investigaciones y tratamientos a corto, mediano y largo plazo se basan en los resultados de la medición de la PA. Por lo tanto, las técnicas y/o equipos inadecuados pueden llevar a diagnósticos incorrectos, subestimando o sobreestimando valores y resultando en conductas inadecuadas y pérdidas significativas para la salud y la economía de las personas y las naciones. Una vez realizado el diagnóstico correcto, a medida que avanza el conocimiento sobre la importancia del tratamiento adecuado, con la adopción de valores de normalidad más detallados y objetivos de tratamiento más cuidadosos hacia metas de PA más estrictas, también se refuerza la importancia de la precisión en la medición de la PA. La medición de la PA (descrita a continuación) generalmente se realiza mediante el método tradicional, la llamada medición casual o de consultorio. Con el tiempo, se han agregado alternativas a través del uso de dispositivos semiautomáticos o automáticos por parte del propio paciente, en salas de espera o fuera del consultorio, en su propia residencia o en espacios públicos. Se dio un paso más con el uso de dispositivos semiautomáticos equipados con memoria que permiten mediciones secuenciales fuera del consultorio (AMPA; o MRPA) y otros automáticos que permiten mediciones programadas durante períodos más largos (MAPA). Algunos aspectos en la medición de la PA pueden interferir en la obtención de resultados confiables y, en consecuencia, causar daños en las decisiones a tomar. Estos incluyen la importancia de usar valores promedio, la variación de la PA durante el día y la variabilidad a corto plazo. Estos aspectos han alentado la realización de un mayor número de mediciones en diversas situaciones, y diferentes pautas han abogado por el uso de equipos que promuevan estas acciones. Los dispositivos que realizan MRPA o MAPA, que además de permitir una mayor precisión, cuando se usan juntos, detectan la hipertensión de bata blanca (HBB), la hipertensión enmascarada (HM), las alteraciones de la PA durante el sueño y la hipertensión resistente (HR) (definida en el Capítulo 2 de esta guía), están ganando cada vez más importancia. Teniendo en cuenta estos detalles, debemos enfatizar que la información relacionada con el diagnóstico, la clasificación y el establecimiento de objetivos todavía se basa en la medición de la presión arterial en el consultorio, y por esta razón, se debe prestar toda la atención a la ejecución adecuada de este procedimiento.A hipertensão arterial (HA) é um dos principais fatores de risco modificáveis para morbidade e mortalidade em todo o mundo, sendo um dos maiores fatores de risco para doença arterial coronária, acidente vascular cerebral (AVC) e insuficiência renal. Além disso, é altamente prevalente e atinge mais de um terço da população mundial. A medida da PA é procedimento OBRIGATÓRIO em qualquer atendimento médico ou realizado por diferentes profissionais de saúde. Contudo, ainda é comumente realizada sem os cuidados técnicos necessários. Como o diagnóstico se baseia na medida da PA, fica claro o cuidado que deve haver com as técnicas, os métodos e os equipamentos utilizados na sua realização. Deve-se reforçar que, feito o diagnóstico, toda a investigação e os tratamentos de curto, médio e longo prazos são feitos com base nos resultados da medida da PA. Assim, técnicas e/ou equipamentos inadequados podem levar a diagnósticos incorretos, tanto subestimando quanto superestimando valores e levando a condutas inadequadas e grandes prejuízos à saúde e à economia das pessoas e das nações. Uma vez feito o diagnóstico correto, na medida em que avança o conhecimento da importância do tratamento adequado, com a adoção de valores de normalidade mais detalhados e com objetivos de tratamento mais cuidadosos no sentido do alcance de metas de PA mais rigorosas, fica também reforçada a importância da precisão na medida da PA. A medida da PA (descrita a seguir) é habitualmente feita pelo método tradicional, a assim chamada medida casual ou de consultório. Ao longo do tempo, foram agregadas alternativas a ela, mediante o uso de equipamentos semiautomáticos ou automáticos pelo próprio paciente, nas salas de espera ou fora do consultório, em sua própria residência ou em espaços públicos. Um passo adiante foi dado com o uso de equipamentos semiautomáticos providos de memória que permitem medidas sequenciais fora do consultório (AMPA; ou MRPA) e outros automáticos que permitem medidas programadas por períodos mais prolongados (MAPA). Alguns aspectos na medida da PA podem interferir na obtenção de resultados fidedignos e, consequentemente, causar prejuízo nas condutas a serem tomadas. Entre eles, estão: a importância de serem utilizados valores médios, a variação da PA durante o dia e a variabilidade a curto prazo. Esses aspectos têm estimulado a realização de maior número de medidas em diversas situações, e as diferentes diretrizes têm preconizado o uso de equipamentos que favoreçam essas ações. Ganham cada vez mais espaço os equipamentos que realizam MRPA ou MAPA, que, além de permitirem maior precisão, se empregados em conjunto, detectam a HA do avental branco (HAB), HA mascarada (HM), alterações da PA no sono e HA resistente (HAR) (definidos no Capítulo 2 desta diretriz). Resguardados esses detalhes, devemos ressaltar que as informações relacionadas a diagnóstico, classificação e estabelecimento de metas ainda são baseadas na medida da PA de consultório e, por esse motivo, toda a atenção deve ser dada à realização desse procedimento

    Pervasive gaps in Amazonian ecological research

    Get PDF
    Biodiversity loss is one of the main challenges of our time,1,2 and attempts to address it require a clear un derstanding of how ecological communities respond to environmental change across time and space.3,4 While the increasing availability of global databases on ecological communities has advanced our knowledge of biodiversity sensitivity to environmental changes,5–7 vast areas of the tropics remain understudied.8–11 In the American tropics, Amazonia stands out as the world’s most diverse rainforest and the primary source of Neotropical biodiversity,12 but it remains among the least known forests in America and is often underrepre sented in biodiversity databases.13–15 To worsen this situation, human-induced modifications16,17 may elim inate pieces of the Amazon’s biodiversity puzzle before we can use them to understand how ecological com munities are responding. To increase generalization and applicability of biodiversity knowledge,18,19 it is thus crucial to reduce biases in ecological research, particularly in regions projected to face the most pronounced environmental changes. We integrate ecological community metadata of 7,694 sampling sites for multiple or ganism groups in a machine learning model framework to map the research probability across the Brazilian Amazonia, while identifying the region’s vulnerability to environmental change. 15%–18% of the most ne glected areas in ecological research are expected to experience severe climate or land use changes by 2050. This means that unless we take immediate action, we will not be able to establish their current status, much less monitor how it is changing and what is being lostinfo:eu-repo/semantics/publishedVersio

    Pervasive gaps in Amazonian ecological research

    Get PDF
    corecore